Leaking water valve
8478 of 12456 people
found this instruction helpful.
-
James from Centerville, OH
- Easy
- Less than 15 mins
-
Nutdriver, Socket set, Wrench (Adjustable)
Removed black cardboard covering on back of refrig with nut driver (6 screws), turned off water supply to pump, removed cooper waterline to pump with adjustable wrench, removed 1 screw holding pump to refrigerator, removed plastic waterline from pump by turning hose counter clockwise. Inserter plastic water line in new pump by screwing li
... Read more
ne in clockwise, pushed orange plastic stop around waterline into pump, connected cooper water line to pump first wrapping threads on pump with teflon plumbers tape, reinstalled pump to refrig and cardboard back on refrig with 6 screws.
One side note:.
This is the second pump which has burst at the blue plastic seam in seven years.
One side note:.
This is the second pump which has burst at the blue plastic seam in seven years.
Read less
Was this helpful?
Thank you for voting!
Replace water filter
226 of 350 people
found this instruction helpful.
-
Alfred from Novato, CA
- Really Easy
- Less than 15 mins
Unscrew old filter and remove(counterclockwise). Line up arrow on new filter with arrow on connection housing. Turn clockwise till resistance met. Do not overtighten. Follow directions. Simple.
Was this helpful?
Thank you for voting!
Water leaked out on floor from behind refrigerator.
171 of 260 people
found this instruction helpful.
-
Eric from Westerville, OH
- Really Easy
- Less than 15 mins
-
Wrench set
First turned water source off and unplugged fridge. Then removed back panel, turned water supply back on and saw leak from valve. Turned water off again and ordered new valve. Paid for 3-5 day shipping, but it came next day! Removed single bolt holding bracket it place. Simple firm pull release of water lines feeding from valve. Unscrewed
... Read more
brass water supply nut with crescent wrench. Marked four electrical leads so I'd know where to replace them. Then repeated process in reverse to install new valve. Simply push water lines back into color coded valve outlets.Also replaced water filter and found that the GWF Filter is now the MWF fitler.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Sticking Light Switch
122 of 178 people
found this instruction helpful.
-
Jonathan from Lilburn, GA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the c
... Read more
atch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
Read less
Was this helpful?
Thank you for voting!
Water dispenser did not work (ice-maker did work)
90 of 105 people
found this instruction helpful.
-
Alan from Houston, TX
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
This is a side-by-side frige with water and ice dispenser in the left freezer door. I first checked for possible water line freezing in the freezer door or in the water chiller area (behind the vegetable drawers) as described in e-articles I had read, but this did not appear to be the problem. I found two solenoid valve pairs; one that
... Read more
routes dispenser or ice-maker water to the filter and the other that routes the water to the end device. I ran a couple of tests on the solenoid valves and found that the first inlet valve that sends water to the filter did not work, but the second valve that relays the water to the dispenser was still working. By temorarily connecting the wiring for the dispenser solenoid to the functioning ice-maker solenoid, I confirmed that the wiring and switch were working properly and that the problem must be the solenoid itself (it also still hummed when the dispenser button was pressed). The entire quad solenoid valve assembly can be pulled out after removing the one hex-screw on the back of the frige (the assembly is all held together with a bracket). I disconnected the wiring connector to the solenoid valves. I disconnected the plastic water tubing by pushing it toward the fitting and then depressing the tubing inlet ring to release the tubing. I removed the two screws holding the solenoid valve and replaced it.
Read less
Was this helpful?
Thank you for voting!
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
91 of 132 people
found this instruction helpful.
-
Gerald from Benicia, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list
... Read more
so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped working
84 of 117 people
found this instruction helpful.
-
Dan from West Bloomfield, MI
- Really Easy
- Less than 15 mins
-
Nutdriver
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.
The icemaker started making ice very soon after turning the unit on.
The icemaker started making ice very soon after turning the unit on.
Was this helpful?
Thank you for voting!
broken ice maker part
78 of 107 people
found this instruction helpful.
-
Laura Beth from Mandeville, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Simple
Was this helpful?
Thank you for voting!
The oiginal Ice Bucket auger became rusty and discoloered the ice.
66 of 72 people
found this instruction helpful.
-
Michael from Antioch, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I went on line to find the part. Luckily I found PartSelect.com. All I had to do was enter the model number into the search box and scroll through the list of parts.
I ordered the part over the weekend and recieved it on Tuesday!
All I had to do was remove 4 screws from the original Ice Bucket and attach the new one.
Perfec ... Read more t fit in under 15 minutes!
Awesome place to do business with! I hope I never have to do another repair, but if I do I will go to PartSelect first!
I ordered the part over the weekend and recieved it on Tuesday!
All I had to do was remove 4 screws from the original Ice Bucket and attach the new one.
Perfec ... Read more t fit in under 15 minutes!
Awesome place to do business with! I hope I never have to do another repair, but if I do I will go to PartSelect first!
Read less
Was this helpful?
Thank you for voting!
My wife said, "the refrigerator door won't close".
54 of 58 people
found this instruction helpful.
-
Gregory from Zephyrhills, FL
- Really Easy
- 15 - 30 mins
-
Socket set
Our refrigerator is a double door unit with ice and water in the left door. The right door was the one with the problem. It was 5:15 AM when the problem occured. I could see that the door was out of alighnment and had dropped down - preventing it from closing. I lifted the door and closed it. I wrote down the model number and found a
... Read more
detailed drawing of the appliance on the web site "partselect.com". When the hing earrived I compared it to the broken one. I removed all the food stored on the door, put several pieces of wood under the door to shim it to the same height as the adjacent door. I then removed two bolts from the refrigerator with a 1/4" socket set. I put the shim from the old hing aside for later. I removed two bolts from the door with the same socket -Note a metal tab had to be bent silghtly so the wrench could go on the head of the bolt- I removed the plastic cam and made note of its orientation and that of the shim above it on the door. I put the shim and new cam in place on the door and installed the 2 bolts. I inserted the pin of the new hing into the hole in the cam (I had just mounted) on the door. I put the shim (the one put aside earlyer) behind the hing and replaced the two bolts. I held the shim and hing up against the door as I tightened the two bolts. When I was satisfied that the bolts were tight I removed the wooden blocks that were holding the door up so the door was supported by the new bottom hing assembly. The door now opperates perfectly and the refrigerator was not taken out of service for the repair. Total time including cleanup was a little over 15 minutes.
Read less
Was this helpful?
Thank you for voting!
Not cold & saw ice accumulated on freezer back panel
52 of 64 people
found this instruction helpful.
-
Eddie from Freeport, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain al ... Read more l water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain al ... Read more l water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
Read less
Was this helpful?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
44 of 62 people
found this instruction helpful.
-
James from Greenville, NC
- Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap ou
... Read more
t neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Read less
Was this helpful?
Thank you for voting!
Ice maker quit making ice
40 of 53 people
found this instruction helpful.
-
Jeffrey from Bluefield, WV
- Really Easy
- 30 - 60 mins
-
Nutdriver
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Was this helpful?
Thank you for voting!
water leak on the water valve
44 of 65 people
found this instruction helpful.
-
JAMES from LEDGEWOOD, NJ
- Really Easy
- 15 - 30 mins
-
Screw drivers, Wrench (Adjustable)
I had noticed water on the front left of the fridge on the floor.I thought it was the drain in the freezer so i poured hot water with baking soda into the drain but it didn't help..I pulled the fridge out and saw water dripping from the water valve solenoid.I searched the web for parts and found Parts select.com.I found the part quickly a
... Read more
nd they had pictures from all angles to assure me that it was the exact part which was great.The transaction on line was simple and the part came the next day.I will definitly use this sight again
Read less
Was this helpful?
Thank you for voting!
Refrigerator Not Cooling due to ice buildup on coils
36 of 42 people
found this instruction helpful.
-
FERNANDO from MIAMI, FL
- Really Easy
- 30 - 60 mins
-
Pliers, Screw drivers
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instr ... Read more uctions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instr ... Read more uctions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Read less
Was this helpful?
Thank you for voting!