Replace ice maker
21 of 28 people found this instruction helpful.
  • Gary from Glendale, AZ
  • Easy
  • 15 - 30 mins
  • Screw drivers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice b in had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Was this helpful?
Thank you for voting!
Refrig. Side not cooling enough
22 of 31 people found this instruction helpful.
  • William from Moorestown, NJ
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
Replaced several things: evaporator fan motor, defrost heater element & defrost timer. The motor was the key problem but did the other repairs because they are common failures and are easy to replace and are not that expensive. Changing the motor was tedious because of tight access to it. Took about 2 hrs for me. Fan is working properly b ut not have a problem with water to ice maker not shutting off. I'm researching that problem. (I replace the water valve 2 hrs ago. That was a simple task - took 15 mins.)
Was this helpful?
Thank you for voting!
The refrigirator light would not come on.
26 of 44 people found this instruction helpful.
  • Jania from Novato, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Was this helpful?
Thank you for voting!
Ice maker would not make ice..
19 of 23 people found this instruction helpful.
  • James from Mebane, NC
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers
1) I removed the icemaker and placed on work table.
2) I pried the front plastic cover from the control box to expose the front base.
3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base
4) Using an ohmm eter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Was this helpful?
Thank you for voting!
Frig would stop working every so often. Lots of food got spoiled.
17 of 19 people found this instruction helpful.
  • Rene from Bronx, NY
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!
Was this helpful?
Thank you for voting!
Stripper on the icemaker broke into pieces.
18 of 23 people found this instruction helpful.
  • Tracy from Yuba City, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Was this helpful?
Thank you for voting!
Heater / Defroster not working
16 of 17 people found this instruction helpful.
  • James from Cleveland, OH
  • Really Easy
  • Less than 15 mins
  • Screw drivers, Socket set
The job was fairly easy. Removed 4 screws and removed panel. Disconnected cable assembly, removed 4 more screws holding heater coils. Reconnected cable assembly and replaced screws & panel. Partselect was quick to ship and would do business with them again.
Was this helpful?
Thank you for voting!
Broken water line near solonoid to feed drinking water
20 of 29 people found this instruction helpful.
  • Gregory from Yucca Valley, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Was this helpful?
Thank you for voting!
Cams On Freezer Door Broke
16 of 17 people found this instruction helpful.
  • WALTER from FROSTBURG, MD
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set, Wrench (Adjustable)
Removed top hinge and electrical connector (freezer door has ice and water dispensers) then had to turn off water supply to unit and disconnect the hose to the door and remove the spring protector from the hose -- this required removal of the compression fittings in the water line so spring would come off of the tube. Then removed botto m hinge from the door and used saw to remove the rivet that had held the cam to the hinge, used a nut and bolt to attach new cam. Put other cam (used two) in the hinge and replaced lower hinge unit on the door. Then reattached both hinges to the refrigerator and lined up the door put the spring protector and compression fittings back on plastic tubing and reconnected the water supply and electric fitting, turned on water to unit and prayed there were no leaks. Prayer was answered, the water dispenser worked properly and the ice maker filled with water so I then replaced the hinge cover on top of the unit and the grill at the bottom and had a pepsi. A few years ago I had replaced the cams on the other door which had no water/electic connections and was a much simpler job.
Was this helpful?
Thank you for voting!
Refrigerator to warm freezer ok
16 of 18 people found this instruction helpful.
  • Christopher from Madison Heights, MI
  • Easy
  • Less than 15 mins
  • Nutdriver
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a whil e I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Was this helpful?
Thank you for voting!
Everything in the refrig was freezing
19 of 27 people found this instruction helpful.
  • BRADLEY from CORTLAND, IL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
removed cover by lifting off,removed retainer screw, lowered panel, removed bulb holder, removed slide adjuster and gear, removed 2 screws that mounted temp control unit, reversed process to reassemble. very easy
Was this helpful?
Thank you for voting!
Compressor overheating - Fridge not Cooling
16 of 19 people found this instruction helpful.
  • CHRIS from LAGUNA NIGUEL, CA
  • Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Was this helpful?
Thank you for voting!
loss of refrigeration
15 of 17 people found this instruction helpful.
  • Heather from Pennington, NJ
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Was this helpful?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
15 of 17 people found this instruction helpful.
  • D from ZELLWOOD, FL
  • Easy
  • 15 - 30 mins
  • Screw drivers
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Was this helpful?
Thank you for voting!
Water and Ice acuator had a hole in it. Need to be replaced.
15 of 18 people found this instruction helpful.
  • Lowell H from Gilbert, AZ
  • Really Easy
  • Less than 15 mins
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.