EasyApplianceParts is now PartSelect! We've merged our sites to provide a better shopping experience for you.   Full Details

Find Parts

Parts Departments

Top Model Types

Top Brands

Repair Help

Expert Repair Videos

Keep typing for more specific results...

33118-3 General Electric Refrigerator - Instructions

All Instructions for the 33118-3
1 - 3 of 3

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
Defrost clock failure
9 of 12 people found this instruction helpful.
  • Ronald from Matawan, NJ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Contact points on original defrost clock burnt out after 36 years of continued use. Hotpoint does not stock replacement defrost clock. PartSelect replacement clock was a simple substitute which fits directly into the original mounting bracket. Space is tight to get the part out, so remove screw in upper right hand corner of bracket to d isconnect clock from bracket. Then remove bracket and pull clock out. NOTE: Original part had wire color codes on the clock and the replacement part does not. Make a note of the order of the color connections and connect new clock in the same order. Replacement part has no ground wire since housing is entirely plastic. Push clock back behind frame. Reposition bracket. Install screw to mount bracket to clock. Then screw bracket back into frame. Glad I found Part Select online... saved me the hassle of getting my old spare fridge out of the basement!
Was this helpful?
Thank you for voting!
Not cooling because of ice accumulation. But worked if I manually advanced the timer to defrost; waited for defrost; and advanced timer to end defrost. (Once very 6 to 12 hours.)
6 of 10 people found this instruction helpful.
  • Harold from Teaneck, NJ
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers, Wrench (Adjustable)
Turned off and unplugged refrigerator.
Removed 1 screw (Phillips head) to detach old timer and 2 hex head screws to remove bracket from "beam" in front (bottom) of "fridge"and detach grounding wire. (Slightly difficult to maneuver bracket out of fridge.
Disconnected 4 wires from old timer and attache them to new one. Repl aced (new) timer and bracket. Assumed that separate grounding wire was unnecessary because of cross-wiring between trrminals. (Was I incorrect?)
GE didn't have the timer but PartSelect had a suitable substitute.

It would have been quicker if I knew what I was doing in advance
Was this helpful?
Thank you for voting!
Buildup of ice on coil -timer not working
  • joseph from wall, NJ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
Removed floor grate,romoved screw holding timer,push timer back,removed hex-screw holding bracket,removed ground wire.Removed connectors from old timer and put on new timer,pushed back new timer,mounted bracket,screwed new timer to bracket. Set timer to defrost at 11pm,put back floor grate.
Was this helpful?
Thank you for voting!
All Instructions for the 33118-3
1 - 3 of 3