Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people found this instruction helpful.
  • Florentino from Windsor Locks, CT
  • Easy
  • 30 - 60 mins
  • Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people found this instruction helpful.
  • W from Nellysford, VA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Was this helpful?
Thank you for voting!
Ice Maker was leaking water and causing the ice to freeze into a block
30 of 47 people found this instruction helpful.
  • Shelley from Katy, TX
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Was this helpful?
Thank you for voting!
Icemaker leaked water into ice bin causing a glob of ice
22 of 25 people found this instruction helpful.
  • Kevin from Tyler, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installin g the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people found this instruction helpful.
  • Bob from Hesston, KS
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Was this helpful?
Thank you for voting!
Refrigerator fresh food side warm, freezer frosted over
21 of 26 people found this instruction helpful.
  • Ernest from Shelby, MI
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers
First did the easy part, removed and replaced the defrost timer. Didn't correct the problem.

Then got into the defrost heaters. Big job, because the factory didn't provide for repairs. Had to remove the ice maker because there was one screw holding on the cover panel behind it. The factory installed defrost heaters were run beh ind the freezer coils so I had to cut them out. Then I had to bend the light aluminum sides with heavy pliers to slip the burned out defrost heaters out and replace them with the new defrost heaters. Didn't use the defrost timer, because I was taking it one step at a time.

Now the refrigerator fresh food side maintains 39 degrees and runs 1/10 the time it was running. My wife says it's better than new! Saved $ 2,400 (the replacement she had picked out).
Was this helpful?
Thank you for voting!
Ice Maker broke at the begining of summer !!!!!!
20 of 24 people found this instruction helpful.
  • Darrell from Pepperell, MA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.

I had already removed the old ice maker in order to get the modle number.

I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator i n less than 10 minutes. With in a few hours I had ice again !!!!!

I would definatly use partselect.com again.
Was this helpful?
Thank you for voting!
Ice stripper broken on ice maker
17 of 24 people found this instruction helpful.
  • Kenneth from New Braunfels, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened th e screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Was this helpful?
Thank you for voting!
Old Icemaker noisy and stopped making Ice
18 of 28 people found this instruction helpful.
  • Daniel from Rhinelander, WI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.

The new one was so quiet, I thought it didn't work!

Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!

Thanks!!!
Was this helpful?
Thank you for voting!
Ice water valve leaking
13 of 13 people found this instruction helpful.
  • Byron from Steamboat Springs, CO
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Wrench (Adjustable)
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Was this helpful?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people found this instruction helpful.
  • David from Cedarville, OH
  • A Bit Difficult
  • More than 2 hours
  • Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
Refrigerator was freezing up and not cooling!
14 of 17 people found this instruction helpful.
  • Garryl from Carleton, MI
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Well first I noticed the back of the freezer compartment freezing up and the ice not freezing. I moved all the contents of the freezer to another freezer. I waited and noticed even when pluged in and everything defrosted the fan didn't kick on on the condensing unit! After a few minutes it did kick on and I took a guess that the defrost t imer was probally ok without checking it. I took eight screws out of the back plate and noticed the defrosting tube on the lower part of the coil was broke in half. I knew I had found the problem. It took maybe 10 minutes to remove and about 10 minutes to order the part. Three days later it was at my door. I took my time installing it which only took maybe 30 minutes. It took longer for me to wipe everything down and clean the inside of both compartments than it did to insall the part. Pluged it in and fired it up and problem solved. Thanks Part Select!
Was this helpful?
Thank you for voting!
Broken cup water fill on ice maker
13 of 15 people found this instruction helpful.
  • Matthew from Aurora, CO
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
Was this helpful?
Thank you for voting!
ice maker stopped making ice
20 of 39 people found this instruction helpful.
  • ROBERT from FLAGLER BEACH, FL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I loosened the two top screws, removed the bottom screw, lifted up on ice maker and slid it off, unplugged the wire from refrig. I transfered the wire to the new icemaker, pluged it back in, placed it on the two screws, installed lower screw, tighten top screws. Total time spent less than 15 minutes. The ice maker cost $125.00 with freig ht. Sears wanted $374.00
Was this helpful?
Thank you for voting!
Refrigerator Ice Maker stopped making ice.
18 of 34 people found this instruction helpful.
  • Harold from Oakton, VA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!