Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
2 of 3 people
found this instruction helpful.
-
Cami from Carmel, IN
- A Bit Difficult
- More than 2 hours
-
Screw drivers
evaporator coils were frozen solid and air wasn't flowing across them
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer s ... Read more ide is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
read all directions first, then consider which steps you'd like to take
in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer s ... Read more ide is actually turning and not blocked
- if no blockages and air is flowing between the sides...
- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)
- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it
-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
Read less
Was this helpful?
Thank you for voting!
Leaking water every time ice maker fillls.
1 person
found this instruction helpful.
-
Bill from Granite Bay, CA
- Very Easy
- 15 - 30 mins
-
Screw drivers
Replaced entire ice maker. Turn off water where it comes out of the wall. Loosen two top screws and remove one screw at bottom. Lift unit up and off top screws and swivel out to the right and disconnect power plug from freezer. Warning new unit does not come with: 1. Power Cable 2. Front plastic cover. 3. Wire bail. Install in reverse ord
... Read more
er Do NOT toss old unit until new one is installed and working. My came with the bottom mounting bracket bent so I just used the old one. When installing old power cable into new unit be sure to put small sensor into clip. It's part of the cable harness assembly.
Read less
Was this helpful?
Thank you for voting!
Icemaker stopped making ice
1 person
found this instruction helpful.
-
Bobby from HARLEM, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver
Model#MBF2255KEW (bottom Freezer) Turn fridge and freezer controls OFF. Move fridge out away from wall to give yourself working space and to clean later. Disconnect electrical plug from wall. Turn off water supply at wall or floor. Put down towel to catch excess water and disconnect water hose at water supply, lay it on towel. Move to the
... Read more
inside of freezer and remove freezer bins by pulling the door all the way out as far as it will go and then lifting by the handle up. locate the two hooks in the back and push forward to clear the bar and move to a safe location. Push the two rails all the way back into the freezer. Un plug wire harness from freezer by squeezing both side of the plug at same time and pull off. Remove the 3- 1/4" nut screws (2 at top and 1 at bottom ) from the ice maker and remove. Take the front cover, Wiring harness and wire bail from old ice maker and place it on the new ice maker. Install new ice maker and connect the wiring harness plug to the freezer connection. Hook up water line hose and tighten. Turn water on and check for leaks. Plug fridge into wall outlet and set refrigerator and freezer controls to 3 until refrigerator is cold and then set as needed. Give the ice maker from 3 to 6 hours to freeze and wait for that magical sound of ice being dumped into the bin. Throw away first batch of ice to make sure there are no impurities. Check for the delivery date of the new ice maker before you start and have coolers and ice for perishables. I removed the old one on the delivery date and cleaned the fridge and freezer inside out. I came to this page to get my repair plan and I hope this will help someone else.
Read less
Was this helpful?
Thank you for voting!
Damage to non-stick coating caused water overflow
1 person
found this instruction helpful.
-
Jim from WAUSAU, WI
- Very Easy
- 15 - 30 mins
-
Screw drivers
Repair was as shown in the video except my refrigerator had screws instead of the plastic clips as shown in the video. Just had to loosen the two upper ones and remove the one lower one. All other steps were as shown in the video.
Was this helpful?
Thank you for voting!
Drive ring disintegrated
1 person
found this instruction helpful.
-
Joe from GRANTSVILLE, MD
- Easy
- 15 - 30 mins
Removed all screws on back and 4 on front. That part is easy IF you have a Torx of the right size. Slip out the ice bin a bit and replace the drive ring. Reassembly is a bit harder since some internal shift can occur -- rotate or tilt the whole assembly to get two -- I think -- screws started. No need to over tighten screws; snug is good
... Read more
enough.
Read less
Was this helpful?
Thank you for voting!
Cracked Ice Maker causing leak
1 person
found this instruction helpful.
-
Frankie from Panama City, FL
- Really Easy
- 15 - 30 mins
-
Nutdriver
Removed old ice maker, had to use the wire shutoff from old ice maker installed new one. Very easy repair, very nice product cheapest price on internet.
Was this helpful?
Thank you for voting!
No Ice Production
1 person
found this instruction helpful.
-
Anson from Algonquin, IL
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I performed basic troubleshooting to make sure there was power and water. Based on historical research on this particular ice maker, I decided that the best direction was to replace the entire assembly. I found this item on this site, ordered it and received it a few days later. I basically removed the ice pan and a few items in the freez
... Read more
er, removed the three mounting screws with either a flat blade screwdriver or nut driver, pulled the electrical harness out of the back wall of the freezer and transferred it to the new ice maker and then installed the new unit, really that simple. Iwas concerned at first, not seeing any activity in the new ice maker but after 15 minutes or so I heard ice falling into the ice bin. Well worth replacing seeing how simple this job was.
Read less
Was this helpful?
Thank you for voting!
ice maker quit
1 person
found this instruction helpful.
-
William from Mashpee, MA
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
Removed the elec connection (after unplugging app) found it easier to remove from appliance. Remove the three screws ( do not temove,....just loosen, the top two) bottom must be removed! Insert the power connection, exchange the tilt up rod, line up the water connection and place back on the two top screws. Tighten and relpace the bottom
... Read more
screw. I found out the hard way.... you cant't see the two top screws . The slots on the ice maker just fit over the screw heads.... it's cold in there!!!
Hopoe this helps..
Cape Cod
Hopoe this helps..
Cape Cod
Read less
Was this helpful?
Thank you for voting!
install new icemaker
2 of 4 people
found this instruction helpful.
-
Nancy from Englewood, FL
- Really Easy
- 15 - 30 mins
-
Screw drivers
First had to remove baskets and door from freezer. Removed three screws; removed old ice maker; Attached new ice maker with three screws; removed arm from old ice maker and placed in the new ice maker. Replaced door and baskets
Was this helpful?
Thank you for voting!
IceMaker was leaking
1 person
found this instruction helpful.
-
Stephen from OTTUMWA, IA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Had to remove the freezer door. Held on by 4 screws. Removed bottom screw on old icemaker and loosened the top 2. Slid the old icemaker up, removed the wiring harness and installed it on the new one. Took the wire out that turns the icemaker off and installed it on the new one. Hooked new icemaker on 2 screws, installed bottom screw
... Read more
and installed freezer door. Turned water back on and started making ice.
Read less
Was this helpful?
Thank you for voting!
Kickplate clip broke off
2 of 4 people
found this instruction helpful.
-
Paul from Fort Wayne, IN
- A Bit Difficult
- 15 - 30 mins
-
Pliers, Screw drivers, Socket set
Reattaching the kickplate clip was easy, but the tab that holds in place was broken. It would slide back when the kickplate was installed. I fashioned a replacement tab out of a piece of 3/32 aluminum bent into a U with the hammer. To hold it in place I drilled and tapped one hole and used a 6-32 machine screw.
Was this helpful?
Thank you for voting!
ice maker quit working
1 person
found this instruction helpful.
-
Ted from Aurora, NC
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
Since it was an older appliance I decided to replace the whole ice maker assembly. I carefully disassembled the old one and then installed the new one. piece of cake.
Was this helpful?
Thank you for voting!
Broken ice bin drive ring
1 person
found this instruction helpful.
-
Gordon from Escondido, CA
- Easy
- 15 - 30 mins
-
Screw drivers
Removed 6 screws to get at broken part. Had to remember the disassembly sequence to properly reassemble. The whole process was relatively simple. I saved about $125 which would have been the cost of a repairman coming to the house.
Was this helpful?
Thank you for voting!
Ice Maker Stopped Working
1 person
found this instruction helpful.
-
Mark from Oak Hill, VA
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
This was a very easy fix. I took the old ice maker out, including the electrical harness. Switched the harness and stop bar to the new ice maker on my bench, then installed the new assembly. Ice initially had some hollow cubes. I checked the ice maker for level. But it was fine. Thought it might be moving too fast. But it seems to
... Read more
have cleared up. Perhaps it took some time to completely cool down.
Read less
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people
found this instruction helpful.
-
Richard from North Easton, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi
... Read more
er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Read less
Was this helpful?
Thank you for voting!