light switch would not work
0 of 2 people
found this instruction helpful.
-
Joseph from Destin, FL
- Really Easy
- Less than 15 mins
Popped the old one out with a kitchen knife and popped the new one back in. It tool less than 15 seconds!!
Was this helpful?
Thank you for voting!
The light went out
0 of 2 people
found this instruction helpful.
-
Janet from Flagstaff, AZ
- Easy
- Less than 15 mins
-
Screw drivers
I pried the old one out with a screw driver and pushed the new one in. I expected instructions in the box it came in but there were none.
Was this helpful?
Thank you for voting!
non-functioning refrigerator lite switch
0 of 2 people
found this instruction helpful.
-
Ronald from Billings, MT
- Really Easy
- Less than 15 mins
-
Pliers, Wrench set
My owners manual said to unplug fridge from elec outlet, use a kitchen knife to gently pry off the switch plate
(manual had a pictoral example), unclip the two wire, replace with on new switch and replace the switch. Close
door and plug back in. Open door to check that the lite
works. Walla! It did. Thanks!
Sin ... Read more cerely, Ron Marshall, Billings, MT
(manual had a pictoral example), unclip the two wire, replace with on new switch and replace the switch. Close
door and plug back in. Open door to check that the lite
works. Walla! It did. Thanks!
Sin ... Read more cerely, Ron Marshall, Billings, MT
Read less
Was this helpful?
Thank you for voting!
Switch was not working after a repairman had fixed something else
0 of 4 people
found this instruction helpful.
-
Jackie from Nova, OH
- Really Easy
- Less than 15 mins
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a
... Read more
single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.
Read less
Was this helpful?
Thank you for voting!
noisey fan
0 of 4 people
found this instruction helpful.
-
Richard from Morgan, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
yup
Was this helpful?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
-
John from LAS CRUCES, NM
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove
... Read more
the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Read less
Was this helpful?
Thank you for voting!
condenser motor broke
-
patrick from livonia, MI
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
opened box,read directions,took out bad motor,installed new one.PRESTO CHANGO way to go.
Was this helpful?
Thank you for voting!
Switch didn't work
-
Don from Laramie, WY
- Easy
- 15 - 30 mins
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Was this helpful?
Thank you for voting!
Refrigerator was running very cold
-
Henry from Newland, NC
- Easy
- 15 - 30 mins
-
Pliers, Screw drivers
Unscrewed the right control knob. Removed the left temperature control knob (there is no screw holding it), removed one screw to rear of small panel then pried open from the rear of the small panel, there are two plastic tabs in front of the small panel holding it in place. Unscrewed the failed control unit and replaced it with the new on
... Read more
e. Replaced the small panel and screw then the left side control knob, making sure of the alignment in the "off" position as the knob has to be pressured into a clamp arrangement on the cold control thermostat. Re-screwed the right knob into place, as well.
Read less
Was this helpful?
Thank you for voting!
Condensor fan motor quit working
-
David from New Albany, IN
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this helpful?
Thank you for voting!
Light switch went bad
-
Joseph T. from Morgantown, WV
- Really Easy
- Less than 15 mins
Simply stick a putty knife between the switch and refrig wall. Pop out old swith, remove both wires by pulling off switch by terminals. Throw switch out. Put wires on new switch and push into slot and all done. Nothing to it! Took me 5 minutes if th
Was this helpful?
Thank you for voting!
No light in frig
-
Irene from Whitehall, MT
- Really Easy
- Less than 15 mins
We tried repairing with a new switch which was very easy to install but it didn't fix the problem.
Was this helpful?
Thank you for voting!
Light switch which turns on the lights when the door opens went out
-
Dennis from Lawrenceville, GA
- Really Easy
- Less than 15 mins
-
Nutdriver
This is an easy fix, simply remove and replace. What I was impressed with is that a how to video was provided along with my part. I wish all manufactures would offer this, the video was easy to understand and you had a good view of the operation. Thanks, a job well done.
Was this helpful?
Thank you for voting!
excessive water in condensate pan
-
michael from woodstock, MD
- Really Easy
- 15 - 30 mins
-
Pliers, Socket set
just as video instructions said, very easy just following them ,part arrived in very short time and was exact fit completely satisfied, saved repair man service charges and wait time
Was this helpful?
Thank you for voting!
Condensor motor was frozen
-
john from thibodaux, LA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers
pull unit away from the wall, and unplug it. remove the grill, and cardboard guard on the lower back of the unit. remove Three screws for the motor bracket. Remove the bracket legs from the old motor and assemble them to the new motor. take the fan blade off the old motor, place it on the new. Cut the wires at the old motor, strip th
... Read more
e insulation back, use supplied wire nuts to connect the new motor. Reverse order to reassemble. Plug in unit to test function.
Read less
Was this helpful?
Thank you for voting!