Not cooling properly/ door divider getting hot.
  • Timothy from Granite City, IL
  • Difficult
  • More than 2 hours
  • Nutdriver, Wrench set
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Was this helpful?
Thank you for voting!
Fan motor stopped working
  • john from white pine, TN
  • Really Easy
  • More than 2 hours
  • Screw drivers, Socket set
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Was this helpful?
Thank you for voting!
intermittent loud whirring noise
  • Honz from Tucson, AZ
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Socket set
Moved fridge out from wall, unplugged power cord. Laid on floor, removed 6 screws from cover. Removed one threaded bolt to allow assembly to slide out. Removed special nut, and took fan off. Removed 3 motor mounting bolts. Unscrewed 2 wire nuts, and untwisted wires. (option 1, no ground) Vacuumed entire area around motor. Used 3 bo lts to mount motor to holder assembly, and special nut to install fan. Stripped wires back about 3/4 inch. Twisted two wires together CW, and installed new wire nuts. Slid motor assembly back into slot,(keep wires away from blades) and used one threaded bolt to secure assembly. Reinstalled cover plate with 6 screws. Plugged power cord in to test air flow (out through cover vents). Moved fridge back into place. The loud whirring noise did not stop for a day; then quiet!
Was this helpful?
Thank you for voting!
Both light bulbs had been replaced, but lights did not turn on.
  • Richard from Arlington, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Was this helpful?
Thank you for voting!
Condenser motor stopped working
  • Chris from Greenville, OH
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers, Socket set
Removed bad motor with socket set and pliers then removed the connectors from the old motor and soldered them on the new one. Then installed new motor. Works like new! Problem Solved! Easy fix!
Was this helpful?
Thank you for voting!
Broke the arm off the food compartment rocker switch
  • David from St. Pete Beach, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Pliers, Screw drivers
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Was this helpful?
Thank you for voting!
Freezer was not Defrosting
  • Andrew from Pinckney, MI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw b y the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Was this helpful?
Thank you for voting!
The freezer compartment was not cold enough.
  • Tom from Paducah, KY
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I found the condenser fan was not working so I bought a new condenser fan kit and installed it. Fixed!
Was this helpful?
Thank you for voting!
condenser fan wore out
  • Nancy from Gallatin, TN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
The kit I recieved was perfect. All parts fit and where a perfect match. I will give you an A+ in handling my order and shocked by speed of your delivery.
Was this helpful?
Thank you for voting!
Frozen Lettuce In Crisper
  • Mary E. from Chicago, IL
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this helpful?
Thank you for voting!
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
  • Donald from Strafford, NH
  • Easy
  • 1- 2 hours
  • Socket set
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this helpful?
Thank you for voting!
Long time!
  • Dustin from Lake Zurich, IL
  • Difficult
  • 1- 2 hours
  • Wrench (Adjustable)
Well the repair was not bad the package came in real fast thank you very much. Doing the work was real hard took about an hour to do and then putting it on I do not think it stayed on good still using some duck tape to hold it and the top and bottom are real fat and will not sink on in. I do not know what to do or what I did wrong. I am k ind of afraid to take it off because it might rip. Some of it ripped as I was putting it on too. Do you have any ideas of what I can do or what might be my problem? Thanks.

Sincerley,


Dustin Takla
Was this helpful?
Thank you for voting!
Fan motor worn out
  • Myrna from Decatur, IL
  • Difficult
  • 1- 2 hours
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Was this helpful?
Thank you for voting!
blower motor was going out
  • Robert from Batavia, OH
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers
just had to remove the fan motor the hard thing is getting down to it
Was this helpful?
Thank you for voting!
Freezer and Refrigerator not cooling properly
  • Edward from Sykesville, MD
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set, Wrench set
Researched this problem on the web. Disassembled the main refrigeration unit (slide out freezer floor panel). The cooling coils were completely iced up. Thawed overnight. Tested the coil thermostat with a multimeter and discovered it worked. Note that the activation temp on this thermostat is 15 degrees Fahrenheit so the ice-water bat h test on many web videos will NOT work. My test was in another refrigerator freezer compartment (everyone has two, right?). When the temperature went below 15 and stayed there for 15 minutes, the thermostat opened the circuit. Further investigation revealed that the defrost heater was burnt and shorted. Replaced the defrost heater only to discover that the defrost timer was also broken. After replacing the defrost timer and testing each component thoroughly, the refrigerator is back in service. Freezer maintains about 8 F and the main refrigerator stays at about 36. The unit cycles off properly and the defrost timer is correctly initiating a defrost cycle. Further, when the defrost heater is cycled on, the thermostat correctly shuts it off once the coils are defrosted. Watch the youtube videos. Find your parts and note their specifications so you can test them properly. And good luck.
Was this helpful?
Thank you for voting!
All Instructions for the 1809