My U-line ice maker quit filling.
5 of 7 people found this instruction helpful.
  • Anne from Arlington, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bra cket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Was this helpful?
Thank you for voting!
Making a god awful racket.
5 of 7 people found this instruction helpful.
  • Michael from Locust Grove, VA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Ok its the garage "adult " Beverage chiller.

Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this helpful?
Thank you for voting!
Freezer making loud whining noise-Fridge not cooling well
7 of 13 people found this instruction helpful.
  • Dale from Blaine, MN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was befo re. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this helpful?
Thank you for voting!
Evaporator Fan in Freezer Making Load Noise
4 of 5 people found this instruction helpful.
  • Ralph from SAINT PAUL, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
Was this helpful?
Thank you for voting!
Fan motor stopped working.
5 of 8 people found this instruction helpful.
  • John from Clifton Heights, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Was this helpful?
Thank you for voting!
nosiy fan operation
4 of 5 people found this instruction helpful.
  • TOM from GRANVILLE, MA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Was this helpful?
Thank you for voting!
Fan motor
3 of 3 people found this instruction helpful.
  • Bonnie from DETROIT LAKES, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Remove bottom of freezer by sliding out the gaskets on each side.

Remove back of freezer. 6 screws.

Remove fan cover. 4 screws.

Remove fan. 3 wires to disconnect. 2 screws to take out.

Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws. ... Read more >Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Was this helpful?
Thank you for voting!
Fan was making alot of noise
4 of 6 people found this instruction helpful.
  • JERRY from ALBION, AL
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Socket set
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
Was this helpful?
Thank you for voting!
Noisy freezer evaporator fan motor
4 of 6 people found this instruction helpful.
  • Lloyd from Long Beach, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan mot or is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
Was this helpful?
Thank you for voting!
Mounting bracket was riveted on old motor, mounting bracket holes on new motor were different
2 of 2 people found this instruction helpful.
  • MIKE from ARLINGTON, OR
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
removed shims on screws holding motor together, enlarged hole in mounting bracket so motor screws could also go through mounting brackets.
Was this helpful?
Thank you for voting!
Ice maker working with no production of ice
2 of 2 people found this instruction helpful.
  • Paul from East Northport, NY
  • Really Easy
  • 15 - 30 mins
  • Socket set, Wrench (Adjustable)
Turn off the water source and unplug freezer. Remove copper tube and then remove valve from back of refrigerator. Disconnect plastic tube and power connection. Mark power connection plug top with a "T", this reminder helps with the new valve. Plug power and plastic tube into new valve and screw assembly back into refrigerator. Using a wrench, connect copper tube into valve. Restore water source and plug back in in freezer. Within a couple hours, ice production was back.
Like the other repair stories (that helped me), this job was very easy.
Was this helpful?
Thank you for voting!
Old Valve was dead
2 of 3 people found this instruction helpful.
  • Joseph from Bloomfield Hills, MI
  • Really Easy
  • 15 - 30 mins
  • Pliers
This was very easy and pretty fast to do and its working great...all for $40 bucks ! you can do this...trust me!
Was this helpful?
Thank you for voting!
ice maker quit working
2 of 3 people found this instruction helpful.
  • Randy from Yale, OK
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
Replaced the water valve. I knew that the ice maker was working by watching the movement. It was not getting water to it, s I figured it was the electric water valve and sure enough, that fixed the problem.
Was this helpful?
Thank you for voting!
replacing evaporator fan
2 of 3 people found this instruction helpful.
  • Steve from SAN CARLOS, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
My fridge did not have icemaker add on. The evap fan is in the freezer behind the back panel. Empty the freezer section (into a cooler) and turn the fridge off. Remove all the shelves in freezer section. Remove the shelf support tabs by lifting them up. use phillips head screwdiver to remove back panel in freezer section. Use nut driver t o remove fan shroud. Remove old fan and save the mounting arms. Install mounting arms on new fan and install fan. Install shroud, back panel, shelf mounts and shelves. Thats it!
Was this helpful?
Thank you for voting!
Ice maker was not working.
1 person found this instruction helpful.
  • GREGG from WEST CHESTER, PA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
Was this helpful?
Thank you for voting!
All Instructions for the 12679