Freezer not cooling. Temperature rising.
-
Jeff from Austin, TX
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
One day the ice cream in the freezer seemed mushy, but the ice was still frozen. There was not water in the ice bin. However, the problem resolved itself. This suggested that the defrost timer had become stuck for an extended time, but then continued to run. The fact that the freezer went back to frozen, implies that all the component
... Read more
s of the cooling loop (compressor, condenser & fan, evaporator & fan) were fine. It was possible that the problem was caused by a bad defrost (?evaporator?) thermostat but everything I saw on line suggested that the defrost timer is the culprit about 40 - 50% of the time. Anyway, I followed the instructions in the on-line video at this site for replacing the defrost timer and it was easy. It would have only taken 15 minutes, but I spent a while reading the defrost timer instructions and hunting down a schematic for my refrigerator, to determine which pin the loose wire should go on.
Read less
Was this helpful?
Thank you for voting!
Frozen Lettuce In Crisper
-
Mary E. from Chicago, IL
- Really Easy
- 30 - 60 mins
-
Screw drivers, Socket set
My husband put in in, no problem and all is well. My husband is a mechanic for large machinery/motors so installation was no problem. Thanks, better than buying a new fridge!!!
Was this helpful?
Thank you for voting!
not cooling could hear a clicking noise
-
Deborah from Elkton, MD
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set
With the help of the website I was able to verify that the part I removed (in the area of the clicking sound) was probably the part required for replacement. I ordered it, installed it... IT WORKS (I knew it the moment I plugged in the power cord and heard the compressor kick on). Saved me from buying a new fridge or calling a repairman.
... Read more
I'm a 58 year old woman with no appliance experience. I watched the videos and installed the part without any trouble. Thank you PartSelect for your easy to use website instructions and helpful hints.
Read less
Was this helpful?
Thank you for voting!
Ice on the botton of top freezer
-
Glenn from Capitol Heights, MD
- Easy
- 30 - 60 mins
-
Nutdriver
I just simply eliminated the ice buildup with hot water and a knife. But I still have the Defrost Timer Kit for future use.
Was this helpful?
Thank you for voting!
Refrigerator not shutting off, liquids freezing in fridge
-
Barbara from Apollo, PA
- A Bit Difficult
- 1- 2 hours
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years ol
... Read more
d we opted to just get a new one.
Read less
Was this helpful?
Thank you for voting!
Fan motor worn out
-
Myrna from Decatur, IL
- Difficult
- 1- 2 hours
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's
... Read more
working fine now and I'm a satisfied customer!
Read less
Was this helpful?
Thank you for voting!
wouldn't make ice, door seal was hot to touch, warm in fridge.
-
Dale from Sterling, AK
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere
... Read more
with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Read less
Was this helpful?
Thank you for voting!
blower motor was going out
-
Robert from Batavia, OH
- A Bit Difficult
- 1- 2 hours
-
Pliers, Screw drivers
just had to remove the fan motor the hard thing is getting down to it
Was this helpful?
Thank you for voting!
Fan was making noise, Freezer temperature was erratic
-
Dik from Quincy, MA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove t
... Read more
he entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Read less
Was this helpful?
Thank you for voting!
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
-
Donald from Strafford, NH
- Easy
- 1- 2 hours
-
Socket set
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Was this helpful?
Thank you for voting!
Fan motor stopped working
-
john from white pine, TN
- Really Easy
- More than 2 hours
-
Screw drivers, Socket set
Well I could what laid on the floor and replaced it but I didn't I emptied refrigerator laid it over change the motor then stood it back up actual work about three hours
Was this helpful?
Thank you for voting!
Not cooling properly/ door divider getting hot.
-
Timothy from Granite City, IL
- Difficult
- More than 2 hours
-
Nutdriver, Wrench set
The video of the repair is a helpful guide, but my refrigerator has the compressor very close to the condenser fan motor. With the compressor comes the copper tubing that is all in the way. I had to carefully bend them now and then to allow me to get my hands in position. The how to is easy, but the working with tools in cramped quarters
... Read more
was difficult. I think my Maytag side by side model makes for this job to be difficult, maybe yours may not be so bad. I took a couple of hours to complete. After the first hour, I covered the bare wires, and plugged the frig back in so it could do some cooling. I placed a small in front on the condenser to blow across it. Had a little break, then finished the job.
Read less
Was this helpful?
Thank you for voting!
not cooling
-
larry from indianapolis, IN
- Difficult
- More than 2 hours
-
Pliers, Socket set, Wrench set
removed condenser fan -located behind refrigerator next to compressor, Not much clearance to work, there are 3 screws to remove from condensing motor,sounds easy but clearance is lacking to remove them ,(takes alot of PATIENCE). Then you have to remove the fan blades to be able to get clearance to remove motor!! I wouldn't reccommend tryi
... Read more
ng this repair unless you are a pro.
Read less
Was this helpful?
Thank you for voting!
Both the freezer and bottom of refrig too hot
-
Marcia from Kansas, OK
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Was very simple once I found out where the defrost timer was located. I had a friend walking me through trying to find the location on the phone. Not all models have them in the same place. Once the part was located all I had to do was remove the cover, unplug the old one and plug the new one in just the way the old one came off. The blac
... Read more
k wire was easy to locate on the old and just matched it up. Put the cover back on and plugged it in. It was no time till I started feeling it cool. Checked both top and bottom with thermomater and it was where it should be within 12 hours. I am happy and using it again. Was almost ready to throw it out. Did not know it was so cheap to fix one. Nothing anyone can't handle. If this woman can do it anyone can.
Read less
Was this helpful?
Thank you for voting!
Condensor fan motor quit working
-
David from New Albany, IN
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Was this helpful?
Thank you for voting!