Fridge Air On, Not Cooling
78 of 183 people
found this instruction helpful.
-
Robert from Austin, TX
- Really Easy
- Less than 15 mins
-
Pliers
Previous issue with this refrigerator and I figure after the Hot summer we've had in TX that it overworked itself this summer in the garage! Caught this one before all was lost as it started it's not cooling cycle on a Sunday. Ordered the identical Relay&Overload from Parts Select, 2 days later I'm back to chilling the beer again! Supe
... Read more
r service with diagrams and specs. Very glad parts select is around!
Read less
Was this helpful?
Thank you for voting!
The light switch on the refridgerator broke - no light.
36 of 58 people
found this instruction helpful.
-
David from Albany, OR
- Really Easy
- Less than 15 mins
-
Screw drivers
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.
I'm very pleased!
Was this helpful?
Thank you for voting!
The rubber piece around it was worn out
28 of 35 people
found this instruction helpful.
-
Carmen from Albany, NY
- Easy
- 15 - 30 mins
We just had to find the trick to put it in where it would catch on and the rest was a piece a cake.
You had to put it in the groove where it would catch and snap it in place and the rest went in
pretty easy.
You had to put it in the groove where it would catch and snap it in place and the rest went in
pretty easy.
Was this helpful?
Thank you for voting!
Noticed fridge not cooling as it should
21 of 21 people
found this instruction helpful.
-
Robert from Franklin, TX
- Really Easy
- Less than 15 mins
-
Nutdriver
Removed the lower back panel (10 small screws)Found the condenser motor froze up and not moving air across the cooling coils.So I got a small table fan and set it behind the fridge and it kept the fridge cooling for 3 days till the new fan motor arrived. Removed 3 small screws holding the fan motor in the bracket and unpluged the wiring h
... Read more
arness.Removed the fan from old motor and used it on the new motor.Replaced the fan in the bracket and plugged the wiring harness back in. Worked great. Very easy.Did not have to empty fridge because table fan kept coils cool. Ordering part was easy and shipping fast.Great job guys!!
Read less
Was this helpful?
Thank you for voting!
Orig Ice maker died
18 of 21 people
found this instruction helpful.
-
Al from Frankfort, IL
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
I was able to salvage the existing wiring and simply replace the ice maker itself and the valve located at the bottom-rear of the frig.
Simply removed and replaced the screws, changed the water tube and connected everything back up. I probably spent more time cleaning behind the frig that replacing the parts.
Very p ... Read more leased with how quickly the parts came and everything was included!
Simply removed and replaced the screws, changed the water tube and connected everything back up. I probably spent more time cleaning behind the frig that replacing the parts.
Very p ... Read more leased with how quickly the parts came and everything was included!
Read less
Was this helpful?
Thank you for voting!
We broke the rail. :(
17 of 19 people
found this instruction helpful.
-
heather from union bridge, MD
- Really Easy
- Less than 15 mins
We decided to use our crisper drawers to store sodas. Duh..bad plan. The rail that holds the drawers up cracked in half. So we just had the drawers sitting on the bottom of the fridge. So, I got the new rail THE DAY AFTER I ORDER IT! I just recycled the old one, and slid the new one in. Presto. Perfect fit. Actually, better then perfect.
... Read more
There must have been a defect with my old one, because the new one actually SNAPPED into place, instead if just sitting in the frame. So..I am really pleased.
Read less
Was this helpful?
Thank you for voting!
Water In Bottom Of Refrigerator
15 of 16 people
found this instruction helpful.
-
daniel from acme, PA
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Basically, I read all of the remarks from other people that had the same problem , I replaced both the timer and thr defrost(bi metal) thermostat as the thermostat had a ohmic value when closed that I was not comfortable with. The unit is now up and running and defrosting as it's supposed to do. I could not get those pushdown clips that
... Read more
hold the timer unit , I ended up breaking them off at the plastic post but there was enough of the plastic post showing that a bit of hotmelt glue was able to hold the timer secure.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
front roller wheel broke
19 of 29 people
found this instruction helpful.
-
Anoop from Diamond Bar, CA
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers, Socket set
its not that hard to replace. may need help to tilt fridge on one side so you can get to the bottom to remove wheel.Had to undo all four corner screws/bolts to loosen bottom section and slowly pull out base frame which holds the 4 wheels. this frame is also holding the compressor and fan so be careful.replace wheel and slowly put frame ba
... Read more
ck to position and screw back bolts. pull back fridge to upright position. leave unplugged for a day or two to allow gas to come back to normal level as we had tilted it.plug it back and it works.
thanks
Anoop
thanks
Anoop
Read less
Was this helpful?
Thank you for voting!
I have a fridge in one of my rentals that was missing 2 crisper drawers
17 of 24 people
found this instruction helpful.
-
kevin from macedon, NY
- Really Easy
- Less than 15 mins
I ordered the crispers and they came the next day.I took them out of the box and had them installed in about 30 seconds.It doesn't get any easier than that.The lady on the phone was very helpful when I placed the order.The fact that they came the very next day was amazing to me.
Other Parts Used:
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people
found this instruction helpful.
-
bill from escondido, CA
- Easy
- 15 - 30 mins
-
Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
Was not making ice and the filler tray was chipping material.
16 of 24 people
found this instruction helpful.
-
Robert from Hummelstown, PA
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
With a socket set and screw driver I removed the old ic e maker . It took about 1 hr. I worked slowly as not to make a mistake. The only part that gave me a problem was the plug. You need to take off the face cover to press down on the plastic release clip. Putting it back took half the time because you knew what to look for.Just plug it
... Read more
in and mount the screws back in place , make sure it was level and I had ice in about an hour.
Read less
Was this helpful?
Thank you for voting!
Refrigerator quit refrigerating
15 of 21 people
found this instruction helpful.
-
William from Hudson, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Read less
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people
found this instruction helpful.
-
David from Arnold, ME
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!
Freezer compartment iced over, food thawing,
12 of 13 people
found this instruction helpful.
-
Lawrence from New Bern, NC
- Easy
- Less than 15 mins
-
Nutdriver
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back porti
... Read more
on to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Read less
Was this helpful?
Thank you for voting!
water was leaking down from freezer section to bottom part of unit
13 of 16 people
found this instruction helpful.
-
Eric from miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me a
... Read more
ccess to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.