I had frost build-up in the freezer.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Parts Used:
-
David from Arnold, ME
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
15 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise coming from defrost timer
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Parts Used:
-
Thomas from Pottstown, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
12 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not cycle
removed the defrost timer and replaced with new unit now i have a refrigerator again
Parts Used:
-
Maxine from Birmingham, AL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
12 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
-
martin l. from JACKSONVILLE,, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
12 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken bottom shelf door cap.
Remove old parts, install old bar to new caps and snap in place. So easy even a caveman can do it!
Parts Used:
-
Stephen from West Portsmouth, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
9 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Parts Used:
-
Jorge from Miami, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
10 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan made lots of noise
unplugged refrig.
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugged all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugged all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
Parts Used:
-
jim from bedford, KY
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan not working
unpluged unit, removed 2 panel screws, removed 4 fan screws, disconnected wires, reassembled
Parts Used:
-
Gary from Erving, MA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator had shut down
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Parts Used:
-
Ronald from Martinsville, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
7 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken kickplate
-
Patricia from Ypsilanti, MI
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
8 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
-
David from Roanoke, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
6 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.
Parts Used:
-
John from Redmond, WA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
Parts Used:
-
Dana from Canyon Lake, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers, Socket set
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
-
Wayne from Arlington, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:Less than 15 mins
6 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
shelf bracket broken and gone
I tried to pull out the wire that was sticking out of the side of the 'fridge with the pliers, however I could not get it to come out so I just pushed it in. I then put the new shelf bracket in the opening and set the shelf on it. It was easy.
Parts Used:
-
Deborah from Phoenix, AZ
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!