Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people
found this instruction helpful.
-
Wayne from Arlington, TX
- A Bit Difficult
- Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin
... Read more
g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Read less
Was this helpful?
Thank you for voting!
broken kickplate
8 of 15 people
found this instruction helpful.
-
Patricia from Ypsilanti, MI
- Easy
- Less than 15 mins
just snapped it on,
Was this helpful?
Thank you for voting!
shelf bracket broken and gone
5 of 6 people
found this instruction helpful.
-
Deborah from Phoenix, AZ
- Easy
- Less than 15 mins
-
Pliers
I tried to pull out the wire that was sticking out of the side of the 'fridge with the pliers, however I could not get it to come out so I just pushed it in. I then put the new shelf bracket in the opening and set the shelf on it. It was easy.
Was this helpful?
Thank you for voting!
Icemaker just stopped making ice one night
8 of 15 people
found this instruction helpful.
-
Robert from Center Moriches, NY
- Really Easy
- 15 - 30 mins
-
Nutdriver, Wrench (Adjustable)
I pulled the refrigerator out from the wali slowly so not to damage the water line to the ice maker. Then with a nut driver I removed all the screws holding the back plate on. Being careful not to kink the water line, I used the adjustable wrench to losen the water line feed nut and the nut that goes to the line to the icemaker. Then I re
... Read more
moved the screws holding the valve in place finished unhooking the water lines with my fingers. I then got the new valve and finger tightend the main water supply nut to the inlet side, then I pushed the plastic supply tube going to the icemaker into the valve. The new valve does not use a nut to attach the tubing it is a presure fit very easy.
Read less
Was this helpful?
Thank you for voting!
freezer constantly covered with ice not defrosting
7 of 12 people
found this instruction helpful.
-
michael from millstone, NJ
- Really Easy
- 15 - 30 mins
-
Screw drivers
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twent
... Read more
y minutes and Tim Allen has nothing on me. Mike Milne
Read less
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people
found this instruction helpful.
-
Ernie from Windsor, CA
- Really Easy
- 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is
... Read more
now running as it should.
Read less
Was this helpful?
Thank you for voting!
Refrigerator light would not stay on
4 of 4 people
found this instruction helpful.
-
Dave from Manchester Center, VT
- Easy
- 15 - 30 mins
-
Nutdriver, Socket set
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
reassembled the pieces.
Was this helpful?
Thank you for voting!
The icemaker in my freezer stopped producing ice
5 of 7 people
found this instruction helpful.
-
Edward from Annapolis, MD
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. ... Read more Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. ... Read more Installed the new control unit and reinstalled the icemaker assembly
A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Read less
Was this helpful?
Thank you for voting!
Water Fill Cup Broke
5 of 7 people
found this instruction helpful.
-
Sam from Las Vegas, NV
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Was this helpful?
Thank you for voting!
Light in my refrigerator didn't work.
5 of 7 people
found this instruction helpful.
-
Joseph from Byron Center, MI
- Really Easy
- Less than 15 mins
-
Screw drivers
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved m
... Read more
e $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.
Read less
Was this helpful?
Thank you for voting!
Removed the old parts then connected the new parts.
4 of 4 people
found this instruction helpful.
-
Jonathan from OLIVE BRANCH, MS
- Really Easy
- 30 - 60 mins
-
Screw drivers
The compressor immediately started when I plugged the refrigerator back in. Around 24 hours later the freezer compartment was at 0 degrees, and the refrigerator was at 35 degrees.
Was this helpful?
Thank you for voting!
Ice maker quit working. Was not getting water.
4 of 4 people
found this instruction helpful.
-
Thomas from ZEPHYRHILLS, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
Took cardboard cover off rear of refrigerator, five screws. Turned water off and unplugged fridge. Took out two screws holding inlet valve, pulled off quick release power wires and changed out water supplies in and out. Rebooked power and replaces cardboard cover. With power and water back on, ice maker was supplied with water.
Was this helpful?
Thank you for voting!
Bad module on icemaker
4 of 4 people
found this instruction helpful.
-
Randy from LAFAYETTE, LA
- Really Easy
- 30 - 60 mins
-
Screw drivers
First shut off water supply and unplug power. Unscrew icemaker assembly from side wall with 3 screws. Remove front cap and you can clearly see module. Unscrew and remove module ( only three screws). Install new module and revers procedure to finish up. Ice was ready in just a few hours. Video provided by this site was right on and left
... Read more
no questions.
Read less
Was this helpful?
Thank you for voting!
Refrigerator light would not turn on.
5 of 8 people
found this instruction helpful.
-
Suzanne from STERLING HTS, MI
- Really Easy
- Less than 15 mins
-
Nutdriver
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom.
... Read more
The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
Read less
Was this helpful?
Thank you for voting!
Filler tube broken and old tube frozen over
4 of 5 people
found this instruction helpful.
-
Alan from Chino, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers, Screw drivers
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube
... Read more
( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
doesn't that feel great?
Read less
Was this helpful?