The refridgerator will not run
2 of 3 people
found this instruction helpful.
-
Victor from Colton, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
After the front panel was removed, disconnected the timer and installed new in reverse order. The provided instructions could be more straight forward, I spent more time reading it than the installation itself.
Was this helpful?
Thank you for voting!
replacing evaporator fan
2 of 3 people
found this instruction helpful.
-
Steve from SAN CARLOS, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
My fridge did not have icemaker add on. The evap fan is in the freezer behind the back panel. Empty the freezer section (into a cooler) and turn the fridge off. Remove all the shelves in freezer section. Remove the shelf support tabs by lifting them up. use phillips head screwdiver to remove back panel in freezer section. Use nut driver t
... Read more
o remove fan shroud. Remove old fan and save the mounting arms. Install mounting arms on new fan and install fan. Install shroud, back panel, shelf mounts and shelves. Thats it!
Read less
Was this helpful?
Thank you for voting!
noisy fridge, perimeter of door heating up
2 of 3 people
found this instruction helpful.
-
craig from maple grove, MN
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Was this helpful?
Thank you for voting!
Condenser fan motor froze up
2 of 4 people
found this instruction helpful.
-
Douglas from Mesa, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people
found this instruction helpful.
-
Richard from North Easton, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi
... Read more
er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Read less
Was this helpful?
Thank you for voting!
freezer would not freeze
1 person
found this instruction helpful.
-
Michael from HELENDALE, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thic
... Read more
k. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Read less
Was this helpful?
Thank you for voting!
Freezer was working but fridge was barely cooling. Look further into how to test thermostat.
1 person
found this instruction helpful.
-
Bonnie E from MODESTO, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver
I just replaced my defrost thermostat after using the place-in-ice-water method, and I think it may not have been necessary. My timeline: my fridge was not getting cold enough. I realized it the day before going on a trip. I vacuumed the (very dusty) coils at the bottom, and the next morning the fridge seemed colder, but I thought I s
... Read more
hould order parts just in case. I ordered a heater and a thermostat. The fridge seemed to be operating normally when I returned from my trip, but I had the parts, so I thought I'd go ahead and dismantle the freezer and test the existing parts. My intention was to return both parts if the old ones passed the tests. I opened up the back of the freezer and there was no ice on the fins. I thought, great, the existing heater works! I cut out the thermostat, placed it in ice water, and didn't get continuity. So I decided to go ahead and put in the new thermostat. Because I'm not experienced with using a multimeter, I thought I'd test the new thermostat to see how the test should work. To my surprise, the new thermostat also failed the test! Stumped, I thought I might as well install the new thermostat, since I had opened the package and couldn't return it.
Further internet research suggests the place-in-ice-water method of testing is not adequate. One YouTube video by Parts Dr says to place the part in a working freezer. I froze my old thermostat and tested it; still no continuity. This thermostat may not be typical, though. The video discussed the temperature ratings on thermostats. The temperature rating on both (old and new) thermostats is L8.9-16.7C. That converts to 48-63 degrees fahrenheit, which obviously are not freezing temperatures. I'm not convinced I needed a new thermostat, but I trusted the videos I consulted earlier.
I cleaned the fridge thoroughly, so at least now I have a nice clean fridge to show for my efforts.
Further internet research suggests the place-in-ice-water method of testing is not adequate. One YouTube video by Parts Dr says to place the part in a working freezer. I froze my old thermostat and tested it; still no continuity. This thermostat may not be typical, though. The video discussed the temperature ratings on thermostats. The temperature rating on both (old and new) thermostats is L8.9-16.7C. That converts to 48-63 degrees fahrenheit, which obviously are not freezing temperatures. I'm not convinced I needed a new thermostat, but I trusted the videos I consulted earlier.
I cleaned the fridge thoroughly, so at least now I have a nice clean fridge to show for my efforts.
Read less
Was this helpful?
Thank you for voting!
Shelf studs broke several years ago and I had a problem locating them. Finally wised up and checked Part Direct and found them, ordered the kit w/ 12 pieces. Then quickly watched the installation video. Took less than 30 minutes to replace two different studs. Wife is very happy.
1 person
found this instruction helpful.
-
Karl from BIRDSBORO, PA
- Easy
- 15 - 30 mins
-
Pliers
Simply took broken pieces of old stud out and replaced with the new ones. Used pliers to adjust them. Replace a freezer stud and a fridge stud.
Was this helpful?
Thank you for voting!
Freezer made lots of Ice and Refrigerator didn't cool
4 of 10 people
found this instruction helpful.
-
Cecelia from Garden City, TX
- Really Easy
- 30 - 60 mins
-
Screw drivers
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator bran
... Read more
d new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
Read less
Was this helpful?
Thank you for voting!
The frig was running too long. the frig was warm the freezer cold
1 person
found this instruction helpful.
-
MARY from S RICHMOND HL, NY
- Really Easy
- 30 - 60 mins
-
Nutdriver
Check for Video if any, watch 2X. The parts may look different (but not this time) Unplug.Defrost timer-dropped the control panel in the frig. the defrost timer sits right in the middle switch it out.Turn the timer to be set on the on cycle. Wasn't sure if the Bimetal thermostat was bad too so for a little over $20. I changed that too.-
... Read more
in the freezer- remove the metal panel and fan cover. its clipped on to the element tubing on the right. cut the wire. Splice the wire to connect the new one then cover with wire nuts. replace cover, plug in. use frig thermometer to verify temperature.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
freezer and refrigerator too warm
1 person
found this instruction helpful.
-
Lillian from AUSTIN, TX
- Really Easy
- 1- 2 hours
-
Nutdriver
followed directions
Other Parts Used:
Was this helpful?
Thank you for voting!
original motor stopped
2 of 4 people
found this instruction helpful.
-
Paul from Lowell, MI
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this helpful?
Thank you for voting!
broken end caps
1 person
found this instruction helpful.
-
Patrick from Narragansett, RI
- Really Easy
- Less than 15 mins
snapped the new ones on the aluminum bar and inserted into the freezer
Was this helpful?
Thank you for voting!
Freezer occasionally had a temperature alarm.Clicking noise also.
1 person
found this instruction helpful.
-
Barry from FORD CITY, PA
- Really Easy
- Less than 15 mins
Was told capacitor was problem 90% of the time.Capacior was not the problem.Bad start relay.
Was this helpful?
Thank you for voting!
Broken wheel on leveling roller
2 of 4 people
found this instruction helpful.
-
Max from Jonesboro, AR
- Really Easy
- Less than 15 mins
-
Socket set
I removed one bolt and took out the old roller after first blocking up the fridge. Then I was puzzled for a moment because the hole in the new assembly was not tapped. But then I saw that the old bolt was a self tapping bolt. I used it to tap the hole then removed it and installed the new assembly. No sweat job.
Was this helpful?
Thank you for voting!