door hinge broke.
2 of 4 people
found this instruction helpful.
-
Bernard from DONALDSONVLLE, LA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Removed door and replaced bushing bracket was ok.
Was this helpful?
Thank you for voting!
Warm refrigerater
1 person
found this instruction helpful.
-
charles from REDDING, CA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Followed instructions from ideoo
Was this helpful?
Thank you for voting!
Condenser fan motor froze up
2 of 4 people
found this instruction helpful.
-
Douglas from Mesa, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this helpful?
Thank you for voting!
Freezer no longer frost free.
1 person
found this instruction helpful.
-
anthony from NORCROSS, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Reviewed Youtube video as a reference. Unplugged refrigerator. Removed old defrost timer. Matched the color of the wiring harness to the diagram that came with the part. Attach new part to wiring harness.
Was this helpful?
Thank you for voting!
compressor not running
1 person
found this instruction helpful.
-
Doug from Lancaster, CA
- Really Easy
- 15 - 30 mins
Removed the access panel on back of unit located the Run Capacitor on the compressor and removed the bad one and put the new one on and pugged refrigerator back in and it started up and works fine now
Was this helpful?
Thank you for voting!
No cold
1 person
found this instruction helpful.
-
Jacqueline from LEXINGTON PK, MD
- Very Easy
- Less than 15 mins
-
Nutdriver, Pliers
Like you video
Was this helpful?
Thank you for voting!
One of the front wheels was broken in half.
1 person
found this instruction helpful.
-
John from INNSBROOK, MO
- Very Easy
- 15 - 30 mins
-
Nutdriver
Very easy. Left the front of the refrigerator so it is approx. 4 inches of the floor. (used a two by four. Removed the screws (one for each roller). Removed the rollers and replaced with new rollers. Reinstalled the screws with secures the rollers to the refrigerator. Done
Was this helpful?
Thank you for voting!
Shelf studs broke several years ago and I had a problem locating them. Finally wised up and checked Part Direct and found them, ordered the kit w/ 12 pieces. Then quickly watched the installation video. Took less than 30 minutes to replace two different studs. Wife is very happy.
1 person
found this instruction helpful.
-
Karl from BIRDSBORO, PA
- Easy
- 15 - 30 mins
-
Pliers
Simply took broken pieces of old stud out and replaced with the new ones. Used pliers to adjust them. Replace a freezer stud and a fridge stud.
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people
found this instruction helpful.
-
Richard from North Easton, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi
... Read more
er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Read less
Was this helpful?
Thank you for voting!
freezer would not freeze
1 person
found this instruction helpful.
-
Michael from HELENDALE, CA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
inst said,"50 pct of the time this calls for new capacitor," so we changed the capacitor. Same prob. It also said,"25 pct of the time it's the bi-metal thermostat" So we ordered it. We removed the plastic rear panel from inside the freezer comp. using small nut driver. Here we found much ICE surrounding the defrost unit, three inches thic
... Read more
k. We thawed the whole mess. and the freezer has worked fine ever since. I think my habit of getting ice cubes from the inside container rather than from the ice cube dispenser, had kep t the freezer door open too much, interfering with the normal defrost cycle and allowing ice to build up over time so that it finally defeated the system. My new rule, "get ice cubes only from the front."
Read less
Was this helpful?
Thank you for voting!
Freezer made lots of Ice and Refrigerator didn't cool
4 of 10 people
found this instruction helpful.
-
Cecelia from Garden City, TX
- Really Easy
- 30 - 60 mins
-
Screw drivers
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator bran
... Read more
d new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
Read less
Was this helpful?
Thank you for voting!
original motor stopped
2 of 4 people
found this instruction helpful.
-
Paul from Lowell, MI
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this helpful?
Thank you for voting!
cooling fan quit
1 of 2 people
found this instruction helpful.
-
George from Belhaven, NC
- Easy
- 30 - 60 mins
-
Nutdriver
Ordered new fan motor on line took out old motor and replaced with new one
Was this helpful?
Thank you for voting!
Condenser Fan Failure
2 of 5 people
found this instruction helpful.
-
Al from Tonka Bay, MN
- Easy
- 30 - 60 mins
-
Socket set
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great
... Read more
!
Read less
Was this helpful?
Thank you for voting!
Refrigerator compartment warm
1 of 2 people
found this instruction helpful.
-
alfonso from Fairfield, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
first confirm that freezer is cold. if is frozen solid it needs to be defrosted. take the freezer items out,take shelf out, bottom cover, 2 screws. then ice maker, 3 screws and unplug wires. then back panel 2 screws. In refrigerator compartment were the controllers are located, look under it you will see 1 hole, insert a flat end screw dr
... Read more
iver and turn clockwise till it stops. this action will turn on your defroster, also the compressor will stop. is the heater melting the ice? if so soak up water and clean tray, use hair dryer in drain hole to aid in the defrost, check tray under fridge and if its dry keep defrosting. it should take half an hour. now take the flat head screw driver and turn the defrost timer clock wise out of defrost mode a quarter turn or so. the compressor should come back on, soon after the fan in the freezer compartment should also come on. this steps lets you no that the defrost heater works, fan works and drain hole is clear. if its defrosted place parts back in the reverse order. if not defrosted replace heater or mother board. in refrigerator compartment were the dials are located their are 2 screws, one on the left and the other on the right side take them out, the cover will drop down, you will find wiring schematics you will need them to install defrost timer. is timer making ticking sound? if no replace timer. new timer will be different from original so follow instructions that come with it. timer is above were the hole is located. the plastic hold downs will break when you try to take them off, unplug fridge, lift timer out and remove from wire harness. the new timer has a black wire that slips over either 1 or 2 depending on color of wire on the wire harness. check schematics. some silicone adhesive will keep unit in place, ad some into the plastic shaft prior to installation, plug wire harness return wiring instruction along with new one inside of cover, plug in fridge, turn defrost timer clock wise with flat head screw driver making sure that you hold timer from above so it wont move. did compressor come on?. put all paper work inside of cover before installing cover
Read less
Was this helpful?
Thank you for voting!