Your search term must have 3 or more characters.
Ice Door Leaking
13 of 19 people found this instruction helpful.
  • Steve from Metairie, LA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Remove the unit cover by unsnapping from the bottom. Remove the face plate on the switches. The ice door simply snaps off the closing mechanism. The problem I have is that the original door included a heat trace element (keeps the back of the door warm to limit condensation). The new part was simply a new seal. I clipped the leads to the het trace (turn off the fridge before you do that) and put in the new door. When the heat ids on in the house there is no problem with condensation but on warmer days its pretty bad. I cannot find a replacement part with the heating element and have contacted Whirpool. THey haven't responded as of yet.
Was this helpful?
Thank you for voting!
refrigerator door was making a popping noise when opening and closing
10 of 10 people found this instruction helpful.
  • Vincent D from Blackwood, NJ
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Not being a handyman I found this job realtively easy.I took most of stuff off fridge door, to make door easier to handle. I then undid top hinge door screws, 3 of them, lifted door out., replaced 2 cams.When putting door back on fridge, you have to make sure door is in exact position and top hinge is lined up exactly, or door will contin ue to pop a little.It took me a couple of times to get top hinge lined up exactly.
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people found this instruction helpful.
  • Maxine from Birmingham, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people found this instruction helpful.
  • Thomas from Brunswick, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.

Shut off water supply line, and turn of f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.

Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Was this helpful?
Thank you for voting!
Would not dispence ice
14 of 24 people found this instruction helpful.
  • Mike from Chickasha, OK
  • Easy
  • 15 - 30 mins
  • Socket set
Removed screws from front of ice container,replaced drum.
The hardest part was assembly of ice crusher,lucky the arms were lettered as to how they went back together.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
Freezer/refrigerator no air flow
10 of 12 people found this instruction helpful.
  • Jim from Au Sable Forks, NY
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
Using a 1/4" nut driver and a philips screwdriver I removed all the screws in the shelf brackets and coil cover and removed coil cover. Removed fan blade and then faulty motor (held in with clips) Installed new motor-two wires (power) and ground (green) pushed fan blade back on and tested, then reinstalled all panels and shelf brackets.
Was this helpful?
Thank you for voting!
auger blades broken
11 of 15 people found this instruction helpful.
  • Michael from Ponchatoula, LA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed ice bin then pulled front cover with nut driver . Pull small rod from side ( one screw holding rod and spring). Pull auger out. Take plastic nut off end ( CLOCKWISE) LEFT HAND THREAD. Keep all ice crusher blades in order when you pull them off. Install new auger and reverse steps. web site has exploded view. It looks difficult but it isn't.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
Compressor would not kick on automatically
10 of 12 people found this instruction helpful.
  • Robert from Brooklyn Center, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I removed the two screws that were readily in view. I then figured out the there was a faceplate which I was able to pry off after removing the temp control knobs. The temp control unit was easily accessible and was held by two screws which I removed with the nut driver. The only difficult part was replacing the plastic tubing which co vered the sending unit.
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!
Worn out door chute
14 of 25 people found this instruction helpful.
  • Murali from Rochester, MN
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
Pry open the front dispenser outer cover. Remove a screw holding ice door dispenser unit, remove old door chute, remove and place coil kind of stuff (connecting to panel) old chute to new one and reinstall.
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people found this instruction helpful.
  • dominique from COMPTON, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Was this helpful?
Thank you for voting!
ice maker was leaking water
13 of 22 people found this instruction helpful.
  • Sandra from Temecula, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Parts went right into place as the pictures showed and was working again in about 30 minutes. The only thing that wasn't working was the ice took forever to make, but solved that problem by turning up the temp in the freezer.
Was this helpful?
Thank you for voting!
All Instructions for the 1069552620