Top half of freezer & fridge were not cooling. Freezer fan had been making unusually loud noises.
3 of 3 people
found this instruction helpful.
-
rich from PEMBROKE PNES, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver
Piece of cake. It took me longer to remove the food from the freezer, remove shelves and back panel than to do the repair. I heard the fan making some noises so I replaced both the fan and defrost thermostat. I used the instructions submitted by a another customer. My 20+ year old fridge is like new now.
Was this helpful?
Thank you for voting!
Compressor making excessive noise
5 of 9 people
found this instruction helpful.
-
chester from Tampa, FL
- Easy
- 30 - 60 mins
-
Nutdriver, Socket set
One front roller was flat on one side. Decided to replace all rollers at same time. Placed shims under unit and removed mounting screws for one front and one rear roller. With new rollers in place, I was able to level the refrigerator side to side, but unable to do so, front to back. Left the new front roller in place and reinstalled
... Read more
the old rear roller. Have decided to replace refrigeratorin the near future. This is one of my few repair failures!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Broken Freezer Door Cams
3 of 3 people
found this instruction helpful.
-
Dennis from Corona, CA
- Easy
- 30 - 60 mins
-
Socket set
1. Put pieces of wood under door to support it.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver ... Read more through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
2. Unscrew three screws holding door hinge.
3. Disconnect water line.
4. Unscrew screw holding each cam. One to door and one to hinge.
5 Replace cams.
6. Retrieve plate with threaded holes behind frame that the hinge attaches to.
7. Use thin philips screwdriver ... Read more through the hinge bracket, shim, frame and screw plate to align it for the other two screws.
8. Replace all three hinge screws.
9. Connect water line fitting.
10. Remove wood for door support.
11. Check door for smooth movement and strong pressure when closed.
Read less
Was this helpful?
Thank you for voting!
light on inside, fridge and freezer warm up after initially cooling
3 of 4 people
found this instruction helpful.
-
paul from patterson, CA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Fridge/freezer warm. After unpluging and plug in again, both would get cold. Then, ice would partially melt in the freezer only to refreeze later. Noted large temperature swings in freezer-up to 48 degrees during defrost cycle. Finally after a day or two, both sides warming up permanently to room temp. Tapping inside the fridge near th
... Read more
e cold control (thermostat) would cause the warm fridge/freezer to cool again. Installation is simple. Remove knobs and snap on face plate in front top of fridge. Remove screws allowing plastic cover to drop down which houses the thermostat at the inside top of fridge. loosen two mounting hex head screws from thermostat mount. Remove two plastic covers concealing thermostat wire that travels to vent at back of fridge. Remove thermostat. remove plastic tube over wire on old thermostat by slipping it forward and slide tube on to new thermostat wire. Install is the same in reverse. A thermometer in the freezer confirms very little temperature variation after install (3-4degrees); ice no longer melts, unit stays on!
Read less
Was this helpful?
Thank you for voting!
freezer section freezing up ( not defrosting )
3 of 4 people
found this instruction helpful.
-
John from COLUMBIA, LA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
ordered the parts ,defrost timer and bi-metal thermostat,assumed it would be more practical to replace both than take a chance . watched a video on how to disassemble the control panel and remove the the timer and the back panel of freezer for the bi-metal thermostat,very clear instructions provided .took about 25 minutes to replace both
... Read more
parts and now is working properly again,,Thanks Again PartSelect for the fast service and delivery
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people
found this instruction helpful.
-
anthony from HAVELOCK, NC
- Really Easy
- 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
the light socket broke apart
4 of 7 people
found this instruction helpful.
-
Elyse from Skokie, IL
- Really Easy
- 15 - 30 mins
-
Screw drivers
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this helpful?
Thank you for voting!
Refrigerator would not stay cold and freezer would thaw.
3 of 4 people
found this instruction helpful.
-
Michael from SYLVA, NC
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
I watched the repair video and did exactly as described. Excellent video and step by step instructions. Follow them and you cannot go wrong.
Was this helpful?
Thank you for voting!
shelf stud had broken
3 of 4 people
found this instruction helpful.
-
cal from lakeside, CA
- A Bit Difficult
- 30 - 60 mins
-
Pliers, Screw drivers
pryed out old stub of stud with the tip of a flat head screw driver. It really did not want to come out because of the metal wings on the side of the stud. When I finally got it out the hole was a little rough but the new stud fit in the old hole and was not to wobbley. The shelf is heavy enough to make it stable. The new stud is also lon
... Read more
g enough to support the shelf even though the hole was not really in new condition after the old stud was pried out.
Read less
Was this helpful?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
3 of 4 people
found this instruction helpful.
-
George from ENDWELL, NY
- A Bit Difficult
- 30 - 60 mins
-
Screw drivers
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when
... Read more
you try and remove the cable assembly. Hope this is helpful.
Read less
Was this helpful?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
3 of 4 people
found this instruction helpful.
-
Richard from Blue Ridge, TX
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end
... Read more
cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Read less
Was this helpful?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
3 of 4 people
found this instruction helpful.
-
David from Hemet, CA
- Really Easy
- Less than 15 mins
-
Pliers, Screw drivers
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull t
... Read more
he connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Read less
Was this helpful?
Thank you for voting!
Refrigerator door on a side by side unit would not stay closed.
3 of 4 people
found this instruction helpful.
-
John from Conyers, GA
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
First empty the shelves on the refrig. door. Then removed the upper hing cover and removed the three screws holding the hinge to the body of the refrigerator. Lifted the door off the bottom hinge and placed it clear of the unit.
Inspected the bottom hinge and cleaned off the screw holding the closing cam, then with a nutdriver remove ... Read more d the screw holding the cam and removed the cam from the hinge. Installed a new cam closer, secured the cam with a screw. Hanged the door back on the lower hinge and re-installed the upper hinge. Job Complete!
Inspected the bottom hinge and cleaned off the screw holding the closing cam, then with a nutdriver remove ... Read more d the screw holding the cam and removed the cam from the hinge. Installed a new cam closer, secured the cam with a screw. Hanged the door back on the lower hinge and re-installed the upper hinge. Job Complete!
Read less
Was this helpful?
Thank you for voting!
defective light switch
3 of 4 people
found this instruction helpful.
-
THOMAS from WILLARD, OH
- Really Easy
- Less than 15 mins
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this helpful?
Thank you for voting!
frame for top of drawer had plastic side rails cracked
4 of 7 people
found this instruction helpful.
-
Andrew from Rockville, MD
- Really Easy
- Less than 15 mins
just replaced the frame - easy to remove old broken frame and replace with new one
Was this helpful?
Thank you for voting!