Freezer was icing up and leaking. Refrigerator side would not keep cold.
3 of 3 people found this instruction helpful.
  • Camille from Glen Ellyn, IL
  • Easy
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers
We emptied out both sides, refrigerator and freezer, and followed the instructions in your video. We turned it off and disconnected the power. We took off the freezer door first. It made it much easier to get the shelves out and reach way back into the freezer. We removed the light and cover, then the ice auger motor. The back panel wa s easy to lift and remove. The wire assembly was a little hard to understand at first, but when we figured it out it was easy to remove and replace the bimetal defrost thermostat. We did check the video when we had the wire harness out, to make sure we got it right. We reassembled the freezer's inside parts and reattached the door. Before we turned the power back on, we scrubbed down the entire refrigerator. When we turned the power back on, the refrigerator and freezer were operating quietly - no sparks or explosions or shorting out - hooray! And the problems were solved.
The most important resource is your video. It looked like something we could do, and then ordered the parts. Our repair took a long time because we checked the video so many times. Thank you so much for the great information and the excellent parts. We could not have done it without you.
Was this helpful?
Thank you for voting!
Freezer would stop operation either during defrost cycle or normal operation and would intermittently start after the fridge thawed out.
3 of 3 people found this instruction helpful.
  • Jeffrey from HOLLYWOOD, MD
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
I took apart the thermostatic switch and cleaned the contacts (noticed carbon or corrosion dust beneath the switch). I installed the old switch back in the fridge until new switch arrived. This seemed to solve the problem. I ordered a new thermostatic switch and a new defrost timer since these two items if defective, cause similar sympt oms to my problem. I replaced both items and the refrigerator has worked normally since. Replacing both parts was straight forward process. Hope this helps.
Was this helpful?
Thank you for voting!
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
3 of 3 people found this instruction helpful.
  • Richard from STATEN ISLAND, NY
  • Easy
  • 1- 2 hours
  • Nutdriver, Screw drivers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator.
First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them.
Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
Was this helpful?
Thank you for voting!
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
3 of 4 people found this instruction helpful.
  • George from ENDWELL, NY
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
Was this helpful?
Thank you for voting!
Refrigerator would not stay cold and freezer would thaw.
3 of 4 people found this instruction helpful.
  • Michael from SYLVA, NC
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I watched the repair video and did exactly as described. Excellent video and step by step instructions. Follow them and you cannot go wrong.
Was this helpful?
Thank you for voting!
freezer section freezing up ( not defrosting )
3 of 4 people found this instruction helpful.
  • John from COLUMBIA, LA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
ordered the parts ,defrost timer and bi-metal thermostat,assumed it would be more practical to replace both than take a chance . watched a video on how to disassemble the control panel and remove the the timer and the back panel of freezer for the bi-metal thermostat,very clear instructions provided .took about 25 minutes to replace both parts and now is working properly again,,Thanks Again PartSelect for the fast service and delivery
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people found this instruction helpful.
  • anthony from HAVELOCK, NC
  • Really Easy
  • 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
3 of 4 people found this instruction helpful.
  • Richard from Blue Ridge, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Was this helpful?
Thank you for voting!
shelf stud had broken
3 of 4 people found this instruction helpful.
  • cal from lakeside, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers
pryed out old stub of stud with the tip of a flat head screw driver. It really did not want to come out because of the metal wings on the side of the stud. When I finally got it out the hole was a little rough but the new stud fit in the old hole and was not to wobbley. The shelf is heavy enough to make it stable. The new stud is also lon g enough to support the shelf even though the hole was not really in new condition after the old stud was pried out.
Was this helpful?
Thank you for voting!
light on inside, fridge and freezer warm up after initially cooling
3 of 4 people found this instruction helpful.
  • paul from patterson, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Fridge/freezer warm. After unpluging and plug in again, both would get cold. Then, ice would partially melt in the freezer only to refreeze later. Noted large temperature swings in freezer-up to 48 degrees during defrost cycle. Finally after a day or two, both sides warming up permanently to room temp. Tapping inside the fridge near th e cold control (thermostat) would cause the warm fridge/freezer to cool again. Installation is simple. Remove knobs and snap on face plate in front top of fridge. Remove screws allowing plastic cover to drop down which houses the thermostat at the inside top of fridge. loosen two mounting hex head screws from thermostat mount. Remove two plastic covers concealing thermostat wire that travels to vent at back of fridge. Remove thermostat. remove plastic tube over wire on old thermostat by slipping it forward and slide tube on to new thermostat wire. Install is the same in reverse. A thermometer in the freezer confirms very little temperature variation after install (3-4degrees); ice no longer melts, unit stays on!
Was this helpful?
Thank you for voting!
the light socket broke apart
4 of 7 people found this instruction helpful.
  • Elyse from Skokie, IL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this helpful?
Thank you for voting!
frame for top of drawer had plastic side rails cracked
4 of 7 people found this instruction helpful.
  • Andrew from Rockville, MD
  • Really Easy
  • Less than 15 mins
just replaced the frame - easy to remove old broken frame and replace with new one
Was this helpful?
Thank you for voting!
defective light switch
3 of 4 people found this instruction helpful.
  • THOMAS from WILLARD, OH
  • Really Easy
  • Less than 15 mins
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Was this helpful?
Thank you for voting!
Refrigerator door on a side by side unit would not stay closed.
3 of 4 people found this instruction helpful.
  • John from Conyers, GA
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First empty the shelves on the refrig. door. Then removed the upper hing cover and removed the three screws holding the hinge to the body of the refrigerator. Lifted the door off the bottom hinge and placed it clear of the unit.
Inspected the bottom hinge and cleaned off the screw holding the closing cam, then with a nutdriver remove d the screw holding the cam and removed the cam from the hinge. Installed a new cam closer, secured the cam with a screw. Hanged the door back on the lower hinge and re-installed the upper hinge. Job Complete!
Was this helpful?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
3 of 4 people found this instruction helpful.
  • David from Hemet, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull t he connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this helpful?