Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people
found this instruction helpful.
-
dominique from COMPTON, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working
... Read more
like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Read less
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
Contact in thermostat assembly was burned up, making the freezer irregular and the ice would melt, then freeze into a ball!
9 of 12 people
found this instruction helpful.
-
Jennifer from Schertz, TX
- Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
I took off the front cover with the controls. Pulled out the control knobs, unbolted the assembly (which was identical to my replacement part) and proceded to follow the old thermostat tube to the back of the fridge. The tube should be carefully removed, not pulled on, there's a couple of screws holding it in towards the back. I installe
... Read more
d the new part in reverse of how I took out the original part. I'm very happy with how the fridge has come back to life! It was much cheaper to fix it than to replace.
Read less
Was this helpful?
Thank you for voting!
Motor intermittently not working.. Warm Frig.
8 of 9 people
found this instruction helpful.
-
Joseph from Gurnee, IL
- Really Easy
- 30 - 60 mins
-
Screw drivers
Very easy. Take panel off and replace motor.. All wires matched fine. Easiest applance repair I've done..
Was this helpful?
Thank you for voting!
Refrigerator wouldn't kick on unless we tapped the thermostat knob and then the freezer would frost up because it wouldn't kick off
9 of 12 people
found this instruction helpful.
-
Yolanda B from Waterville, ME
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
Unplugged the refrigerator and then removed the knobs and face plate inside, by removing the screws. I then removed the screws holding the thermostat and unplugged the Thermostat assembly, and replaced it with the new one, then removed the defrost timer and replaced with the new one. I then replaced the screws and the face plate, then the
... Read more
knobs. I plugged the refrigerator and it kicked on right away. Within a half hour we had it running and at the right temperature. It was so easy I think my wife could have done it!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people
found this instruction helpful.
-
Jorge from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn
... Read more
ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Read less
Was this helpful?
Thank you for voting!
Shelf stud cracked
7 of 8 people
found this instruction helpful.
-
Jerome from Rochester Hills, MI
- Really Easy
- Less than 15 mins
-
Pliers
From a prior post, I learned that you simply turn the old stud one quarter turn to the left to pull it out. The new stud is then inserted and turned one quarter turn to the right and it locks in. Very easy repair.
Was this helpful?
Thank you for voting!
Freezer No Longer Cools
7 of 8 people
found this instruction helpful.
-
STEPHEN from FENTON, MO
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer wouldn't defrost/low temps in refrigerator
8 of 12 people
found this instruction helpful.
-
Troy from Kansas, OK
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
Was this helpful?
Thank you for voting!
freezer gets too cold then gets to regular tempetured
6 of 6 people
found this instruction helpful.
-
roberto from san Antonio, TX
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people
found this instruction helpful.
-
David from Choctaw, OK
- Easy
- 30 - 60 mins
-
Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin
... Read more
g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Read less
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people
found this instruction helpful.
-
Peter from Herndon, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
fridge and freezer stopped maintaining proper temp
5 of 5 people
found this instruction helpful.
-
Donald from CONWAY SPGS, KS
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed the repair videos that were provided by partselect and installed a bi-metal defrost thermostat in the freezer and a thermostat assembly in the fridge. The installation was not hard and everything is now working as it should. Thanks
Other Parts Used:
Was this helpful?
Thank you for voting!
The frig/freezer shut off too often and would not stay cold.
7 of 11 people
found this instruction helpful.
-
Ron from Eaton Rapids, MI
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy f
... Read more
ix.
Read less
Was this helpful?
Thank you for voting!