The old condenser fan was rattling and driving everyone nutts.
  • William from Salem, WI
  • Really Easy
  • Less than 15 mins
  • Wrench set
I surfed partselect and read that a reader had a similar problem with a rattling fan. I then removed the back panel, after I had unplugged the unit, and was able to feel the slop in the fan shaft. I then watched the video of how to replace the fan and ordered the part soon after. The part arrived 3 days later! Easy to do. I was finis hed in 12 minutes and the fridge runs silently. The part of the job that took the longest was vaccuming the undercarriage. There was alot of dust! Couldn't have helped the efficiency on the fridge. Keep it clean.
Was this helpful?
Thank you for voting!
Noisy fan motor
  • eBooks4u from Wimberley, TX
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
Before I began I unplugged the electrical at the wall outlet. 1. Unscrewed the 4 mounting screws. 2. disconnected electrical at the motor. 3. removed the assembly. 4. mounted the new motor on the assembly as described in the instructions. Installed the assembly and reconnected the electrical. Works great, easy job!
Was this helpful?
Thank you for voting!
condenser fan would not come on, and when it did, made loud noise.
  • Sean from Simi valley, AL
  • Really Easy
  • 15 - 30 mins
  • Socket set
Repair was so simple, I didn't even need instructions. Removed old fan with motor, installed new one, installed harness that converted plugs, done. Saved hundreds of dollars doing the repair myself.
Was this helpful?
Thank you for voting!
My undercounter ice machine grid cutter wire broke
  • Ronnie from Corpus Christi, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I removed the two screws that hold the shield in front of the grid and put them aside allowing access to the grid. I then removed the two screws that hold the grid in place. I unplugged the connector and then pulled it out. I reversed the process to reassemble and powered up the unit. I now have ice again. This whole process probably took me 15-20 minutes to do the install.
Was this helpful?
Thank you for voting!
Wire in ice cutter assembly had broken
  • Paul from Metairie, LA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Removed old assembly by disconnecting 2 wiring harness connections and loosening 2 screws with nutdriver. Installed new assembly using same process. Had ice in about an hour. Very easy.
Was this helpful?
Thank you for voting!
After 5 years the pump gave out, but much cheaper to replace than buy new ice maker
  • Drew from Birmingham, AL
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Socket set
1 Turn off ice maker and drain water reseviour (cap at bottom of reseviour) 2. Remove internal ice storage door to give you more working room 3. Remove water resevious (two screws on either side of reseviour) and disconnect plastic tubing in reseviour 4. Remove cover shield at top that covers the ice cutting mechanism (two screws at botto m of cover 3. Remove cover shield covering pump (1 screw) 4. Remove small plastic tubing on side of pump (this part is a little tricky) 5. Remove the three screws holding pump to unit (one at back and two on the side (one in front of pump and one in back of pump) 6. Disconnect power supply to pump 7. Remove pump and replace
Was this helpful?
Thank you for voting!
Kit did not match up to existing bracket
  • John from Severna Park, MD
  • Difficult
  • 30 - 60 mins
  • Nutdriver, Socket set, Wrench (Adjustable)
fan motor housing had to be drilled through both sides of housing to attach to existing bracket. Possible damage to wiring inside the unit may disable condensor fan motor when motherboard is replaced. (Motherboard on order.)
Was this helpful?
Thank you for voting!
removing broken cutter grid
  • Juergen from Belle Chasse, LA
  • Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the inst ructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Was this helpful?
Thank you for voting!
Condensor fan stopped working, refrigerator got hot.
  • Jon from Mount Juliet, TN
  • Easy
  • 30 - 60 mins
  • Socket set
1. Unplug the refrigerator. 2. Remove the back cover at the bottom of the refrigerator. 3. Remove the two screws holding the vertical black bracket the fan is mounted to. This allows the bracket to move easily. The bracket does not have to be removed. 4. Removed the four screws holding the fan bracket to the vertical bracket. 5. Unpl ug the power connector from the fan motor. 6. Remove the entire fan bracket assembly from the refrigerator. 7. Remove the 4 screws holding the fan motor to the fan motor bracket and unmount the fan motor. 8. Remove the nut holding the fan blade to the fan motor and remove the fan blade. 9. Reverse the process, mounting the fan blade to the new motor, screw the motor to the bracket, screw the bracket to the vertical bracket, screw the vertical bracket to the refrigerator and plug the power connector back into the motor. I did not have to use any of the extra mounting hardware or electrical hardware provided with the kit. It might be a good idea to purchase a new fan blade with the motor kit, the fan blade can get pretty grungy. I cleaned the fan blade with some degreaser before remounting it.
Was this helpful?
Thank you for voting!
Recirculating pump stopped working
  • Gene from Battle creek, MI
  • Easy
  • 30 - 60 mins
  • Nutdriver
Remove ice tray and guard over moter. Un plug the 3 plugs and pull the entire motor assembly out. Use a screw driver to gently pry motor out. Snap in the new motor(the wiring was on the wrong side and the power cord coloring backwards on the replacement motor, but I snapped it in with the colors criss crossed and it worked). Re plug in th e 3 plugs. Re mount mounting assembly, tray and then guard. Had a little trouble getting the tray back in. There is a little flap in the back that goes inside the tray. Other than that, a pretty easy fix.
Was this helpful?
Thank you for voting!
,making one cycle of ice ,then quit
  • william from winnsboro, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers
remove cutter grid (two screws in front)remove cover in front of water pan(two screws)thermister clamps on the line behind the water pan unclamp and replace with new one
Was this helpful?
Thank you for voting!
Water circulation pump not working
  • Peter from Groton, CT
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I determined the pump was not working by running the ice maker. After it started a cycle, I could fell the underside of the cold plate to insure it was indeed cold, but no water was flowing.
First, be sure the water pump electrical plug is in., it releases by pressing together the tabs at the ends, not sides.
To replace the pum p, turn off the water supply and cover the drain hole at the bottom of the ice bin so you don’t drop parts down it. The screw-plug at the bottom of the water tank or a quarter will do.
Remove the water tank below the pump by taking out the thumbscrews at both ends. You can then see the hose at the bottom of the pump. If it is off, that may be the problem.
To remove the pump, pull the fill hose to the left out of the slot and bend it behind the pump to get it out of the way. Unplug the electrical connector and the pump hose. There are three ¼” hex head screws, teo on the side wall, one in back. The middle one is the hardest to access. I used both a nut driver and a socket wrench with a 4” extension.
When installing the new pump, be sure to plug in the electrical connector, the discharge hose at the bottom and position the fill tube as you found it. Forget any of these and nothing works. Re-install the water tank, replace the drain plug and turn on the water supply, in that order.
Was this helpful?
Thank you for voting!
fridge started making an awful noise...still worked but noise occurred when fan kicked on
  • Diane from Rocky Mount, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers, Socket set
My husband watched the video on the repair and followed it step by step...works like a charm! The repair shop wanted 299.55 to fix it - the part was 79.00....big savings by doing it ourselves.
Was this helpful?
Thank you for voting!
Fan motor making noise then failed. Ice maker stopped making ice
  • John from Norman, OK
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench set
Once I determined easier access to the fan motor, I removed the three fan motor screws that held the motor on place. After removing the motor I remove the fan blade assembly held by one nut and reattached to the new motor. I then reattached the new motor with 3 new screws which were provide and reattached the power cord with the cord c lip and began reassembling the icemaker housing, then moved the unit back in place which was installed under counter. I could do this repair in less than 45 minutes now that I have done it once. I saved several hundred $ from the original estimate and the parts were delivered in 2 days after I ordered online. This is definitely a DIY project!!
Was this helpful?
Thank you for voting!
replacing condenser fan motor
  • Norman from Azle, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Socket set
Using a 1/4" ratchet removed the old motor, a bit difficult due to small space to get your hand and ratchet in position. Before installing the new motor I used one of the screws to tap the the 3 holes in the new motor so it would be easier to start the screws attaching motor to mounting bracket. Attached cable. plugged in the fridge. Grea t to hear a quit running refrigerator again.
Was this helpful?
Thank you for voting!