Refrigerator and freezer was not "working " ,ice machine not working.
11 of 12 people
found this instruction helpful.
-
Guy from MUNSTER, IN
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers, Socket set
Removing the panels inside the freezer section was the most difficult ,because it is narrow,hard to fit your body inside compartment, in order to cut wires and to splice Bi-metal Defrost Thermostat wires (2 ) Watch the videos on the web site so you know where to start. First time I ever "repaired " a large appliance, s
... Read more
aved me over $ 600.00 (that's what the people I bought the Refrigerator from wanted to charge me.) My parts cost 65.00 !!!!! My younger brother turned me onto the web site... , I'll be returning to the site and telling my friends about it. It's a total "rip off" what service organizations charge the general public these days from Car Dealer ships to the stores we purchase our appliances from. !!! Glad I still have my health and faculties to repair the essentials we have around our homes. !!!!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people
found this instruction helpful.
-
Maxine from Birmingham, AL
- Really Easy
- 15 - 30 mins
-
Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people
found this instruction helpful.
-
Thomas from Brunswick, OH
- Really Easy
- 15 - 30 mins
-
Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Shut off water supply line, and turn of ... Read more f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.
Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Read less
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people
found this instruction helpful.
-
Robert E. from Darien, IL
- A Bit Difficult
- Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
part of a freezer support bracket was missing
9 of 10 people
found this instruction helpful.
-
peter from saint augustine, FL
- Really Easy
- Less than 15 mins
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people
found this instruction helpful.
-
dominique from COMPTON, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working
... Read more
like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Read less
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people
found this instruction helpful.
-
Jorge from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn
... Read more
ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Read less
Was this helpful?
Thank you for voting!
Freezer No Longer Cools
7 of 8 people
found this instruction helpful.
-
STEPHEN from FENTON, MO
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people
found this instruction helpful.
-
Michael from East Meadow, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
fan not working
7 of 9 people
found this instruction helpful.
-
Gary from Erving, MA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
unpluged unit, removed 2 panel screws, removed 4 fan screws, disconnected wires, reassembled
Was this helpful?
Thank you for voting!
fan made lots of noise
7 of 9 people
found this instruction helpful.
-
jim from bedford, KY
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
unplugged refrig.
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugge ... Read more d all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugge ... Read more d all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
Read less
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people
found this instruction helpful.
-
Antonio from San Antonio, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people
found this instruction helpful.
-
Duncan from Metairie, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?