part of a freezer support bracket was missing
9 of 10 people
found this instruction helpful.
-
peter from saint augustine, FL
- Really Easy
- Less than 15 mins
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people
found this instruction helpful.
-
Robert E. from Darien, IL
- A Bit Difficult
- Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people
found this instruction helpful.
-
Jorge from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn
... Read more
ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Read less
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people
found this instruction helpful.
-
Michael from East Meadow, NY
- Really Easy
- Less than 15 mins
-
Screw drivers
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
fan not working
7 of 9 people
found this instruction helpful.
-
Gary from Erving, MA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
unpluged unit, removed 2 panel screws, removed 4 fan screws, disconnected wires, reassembled
Was this helpful?
Thank you for voting!
fan made lots of noise
7 of 9 people
found this instruction helpful.
-
jim from bedford, KY
- Really Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
unplugged refrig.
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugge ... Read more d all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
removed screws on back panel of freezer compartment
removed fan motor cover
removed fan
broke ends off support bracket in accordance with directions
had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan
plugge ... Read more d all 3 wires into fan motor
replaced covers
every thing works fine now.
part was delivered quite promptly
refrigerator was over 30 years old and a sears model but mfg by whirlpool
Read less
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people
found this instruction helpful.
-
Peter from Herndon, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people
found this instruction helpful.
-
David from Choctaw, OK
- Easy
- 30 - 60 mins
-
Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin
... Read more
g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Read less
Was this helpful?
Thank you for voting!
Ice maker broken
6 of 7 people
found this instruction helpful.
-
Gloria from Folsom, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I had already removed the old Ice maker, so it was no longer in.
When the new ice maker arrived, I simply pluged it in, replaced the screws that hold it in place and turned the water back on to the ice maker.
It was that easy.
When the new ice maker arrived, I simply pluged it in, replaced the screws that hold it in place and turned the water back on to the ice maker.
It was that easy.
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people
found this instruction helpful.
-
Antonio from San Antonio, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
ice tray was leaking water
5 of 5 people
found this instruction helpful.
-
Brenda from Henderson, NV
- Really Easy
- Less than 15 mins
-
Nutdriver
Unplugged wire, loosened two screws on top took out lower screw.Lifted the ice maker up and out it came. The wiring that came with the new part was to short so we unplugged ours from the old part and used it:) was really easy and works great now no leaks
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people
found this instruction helpful.
-
Duncan from Metairie, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!