I had frost build-up in the freezer.
15 of 21 people found this instruction helpful.
  • David from Arnold, ME
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!
Refrigerator quit refrigerating
15 of 21 people found this instruction helpful.
  • William from Hudson, FL
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Was this helpful?
Thank you for voting!
Freezer compartment iced over, food thawing,
12 of 13 people found this instruction helpful.
  • Lawrence from New Bern, NC
  • Easy
  • Less than 15 mins
  • Nutdriver
I deenergized the refigerator, removed the storage tray, three screws that hold the ice maker, two screws that hold the lower portion of the freezer, two screws tjhat hold the back portion of the freezer. Removed the ice maker and disconnected the wire connector and ground, Removed lower portion of the freezer which allowed the back porti on to be lifted out. Once the back was out the bimetal defrost thermostat was located in the upper right corner clipped to a copper line. Using an ohm meter, I found the bimetal defrost thermostat to be electrically open, ordered part from information found on part, Once part arrived I deenergized the refrigerator and replaced bimetal thermostat by cutting the old thermostat wires (pink and brown), stripping the wires back about 5/8 inch and wire nutting the replacement parts like colored wires, clipped the bimetal part on the copper tube, replaced the covers in reverse order, and reenergized the refrigerator. Testing and replacing the part took about 15 minutes, waiting for the ice build up to thaw took considerably longer.
Was this helpful?
Thank you for voting!
water was leaking down from freezer section to bottom part of unit
13 of 16 people found this instruction helpful.
  • Eric from miami, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
First, unplugged the refrigerator. Then removed bottom plastic liner of the freezer, 2 screws with 5/16 nut driver. At this point the ice maker had to be removed 3 screws, two on the upper part and the other under the ice maker. Now the back wall of the freezer section was removed by unscrewing 2 screws with the nut driver. This gave me a ccess to remove the defective clip-on Bimetal defrost thermostat. It was located in the upper right corner on the back wall of the freezer. Cut off the 2 wires from the bad part( one pink the other brown)then used wire nut to replace with the new part and matched wires from freezer to new part( pink to pink and brown to brown) and clipped the part in one section of the coil. ( where the bad part was located) Put all back in place. And so far no more water leak inside the fridge.
Was this helpful?
Thank you for voting!
Noise coming from defrost timer
12 of 14 people found this instruction helpful.
  • Thomas from Pottstown, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Was this helpful?
Thank you for voting!
My refrigerator ran constantly and never got cold!
11 of 12 people found this instruction helpful.
  • Brandon from Fort Wayne, IN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever a nd I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people found this instruction helpful.
  • Maxine from Birmingham, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
Broken gooseneck on fill tube
10 of 11 people found this instruction helpful.
  • Thomas from Brunswick, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
The gooseneck on the icemaker fill tube extends out beyond the back cabinet of the refrigerator, and is easily broken. Luckily, this part is a piece of cake to replace. You'll literally spend more time pulling out your fridge and cleaning out behind it then you will replacing this part.

Shut off water supply line, and turn of f ice maker (lift the metal bar in the ice bucket all the way up). Loosen the hose fitting, and remove two screws. Pull out the old tube, and slide the new one in. You may have to wiggle the tube around from the inside to get the alignment correct. Replace screws and fitting. Turn water and ice maker back on, and check for leaks. It really is that easy! It took me longer to type this than to actually replace the part.

Only one potential catch. The instructions warn that you may have to cut the new tube to match the length of the old tube, so make sure you compare the length of the old and new tube. I didn't have to to do anything - the replacement part was the exact same length of the original. If by chance you do need to cut the tube, you'll need small saw of some sort, such as a coping or hack saw.
Was this helpful?
Thank you for voting!
Crisper Drawer cover broke.
10 of 11 people found this instruction helpful.
  • Monica from Greendale, WI
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
We removed the drawers and drawer cover
(after we'd unloaded that part of the refrigerator!), and
took the glass out of the drawer cover. Then we took
the gaskets off the old cover and put them on the new
one (that's what the screwdriver was for).
It was easy because of the very helpful diagram of all
t he parts that I had used on the web site to order the
part.
Getting the part was amazingly fast - thank you!
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
part of a freezer support bracket was missing
9 of 10 people found this instruction helpful.
  • peter from saint augustine, FL
  • Really Easy
  • Less than 15 mins
I wasn't sure the kit included the part I needed from the pictures, but it did. The part slipped over the flat plastic bracket attached to the right freezer wall and the shelf fit over it. No tools required.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people found this instruction helpful.
  • Robert E. from Darien, IL
  • A Bit Difficult
  • Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!