Icemaker not working
7 of 8 people
found this instruction helpful.
-
Hal from Virginia Beach, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Wrench (Adjustable)
Started the replacement of the existing dual outlet valve by removing cardboard covering the lower back of the refrigerator exposing the outlet valve. Closed the water supply valve at the wall. Removed the hose bibb water supply connection on the outlet valve by hand as it is only hand-tight. I used a small plastic container to catch the
... Read more
minimal amount of water left in the copper line. I removed the electrical connection on each solenoid valve (one for the in-door water supply and one for the icemaker supply). I removed the plastic supply lines from the outlet valve. I removed the screws on the bracket attaching the dual outlet valve to the refrigerator vertical rail. I reconnected the electrical connectors to the valve. I reattached the plastic supply lines to the valve, but did not tighten them fully at this point. I secured the bracket on the new valve to the existing screwholes on the refrigerator rail. The new outlet valve does not have a hose bibb connector, it has a compression fitting for the supply. I reused the existing copper supply line from the wall angle-stop valve to reconnect to the new outlet valve. (It would have been best to have cut the copper line and used a new furrel on the copper line). Note that the supply line now comes into the outlet valve from the top, not the rear as on the old valve, so now the dual outlet valve sticks out beyond the frame of the refrigerator. I tightened the nuts on the plastic supply lines on the valve. I had to cut the cardboard cover around the new outlet valve. Resecured the cardboard cover to the back of the frig. Checked for leaks, turned the icemaker on by lowering the shutoff arm, and after a few moments, the outlet valve opened, water flowed into the icemaker, and all is well.
Read less
Was this helpful?
Thank you for voting!
Refigerator would freeze up and stop cooling, I would turn off defrost over a 24 hour period by leaving the freezer door open. Then turn it back on and it would cool like crazy for about a week and then it would freeze up agian. This went on for about a month then I knwe the problem was in the defro
7 of 8 people
found this instruction helpful.
-
Charles from Dripping Springs, TX
- Difficult
- More than 2 hours
-
Nutdriver, Pliers, Screw drivers
The first thing to do was determine what part of the defrost circuit was bad. (it could have been the defrost timer assembly or the defrost heater or a bad wire in the circuit). To do this I took the cover off of the refrigerator temp control to see the timer. Taking a large screw driver I rotated the timer (clockwise) until I heard the c
... Read more
ompressor cut off. Then I placed a mark on the timer to note its location and waited to see if the mark moved( this indicated the motor was running). After 20 minutes the compressor kicked back on and the timer had rotated, this told me the timer was at least rotating. The next step was to see if there was voltage going to the defrost heater around the freezer evaporation coil. (The heater is what melts the frost of the evaporation (cooling) coils
This requires the removal of all the shelves, ice maker, and all the covers in the freezer section to expose the evaporation coil.
The defrost heater wraps around the outside edges of the evaporation coil. The heater is suppose to come on for 20 minutes every 8 hours to keep the evaporation coil from becoming covered with frost which will prevent the air from circulating into the refrigerator section.
I found where the heater leads plug into the back wall of the freezer and with the power on and in the defrost cycle (turn or index the timer around with the large screw driver until the compressor cuts off again). Carefully read across these two heater leads and check for 120 VAC. Noting there was 120vac across these two leads I then turned the refrigerator off and unplugged the refrigerator from the wall.
Now with the Volt Meter set to the Ohms setting I unplugged the two heater leads with the needle nose pliers and read the ohm value across the two wire leads of the heater element. (I got lucky and found a schematic folded up and stuck just behind the front grill at the bottom of the freezer). The schematic told me the ohm value should have been 22 ohms. However, my value was 0 ohms this told me the heater had an open circuit (it had a broken wire inside the heater element). I located the correct part using the model # on the Part Select website and ordered the defrost heater element for my model refrigerator. I received the part in three days.
Now for the fun part, of removing and installing the new element.
This is not brain surgery but … it is not for the faint at heart either, you must be able to work in tight areas and be agile enough to sit on the floor while reaching the back of the freezer and be patient and deliberate with your moves. (kind of like playing the Milton Bradley game “Operation” as a kid)
Next step is to remove the two top screws holding the evaporation coil to the back of the freezer, then remove the cover to expose the refrigerant lines inside the freezer, remove the two foam side supports holding the coil centered in the back of the freezer and then VERY carefully lift the evaporation coil straight up to un- hook it from the bottom clips which hold the bottom of the coil stationary. Then gently remove the two aluminum side plates from the coil by bending the tabs that hook these plates to the curved refrigerant coils they are hooked around. With the side plates removed then carefully un- hook the 4 clips which hold the heater in place around the evaporation coil. Using a pair of needle nose pliers unplug the heater leads from the back wall contact point (Remember to be sure and unplug refrigerator before doing this) At this point VERY carefully lift up slightly and gently pull the bottom of the coil out (trying to keep the top of the coil at the same elevation and parallel to the back wall pull the bottom out to a point where the heater element can be slid down and out of the evaporation coil as it is basically woven thru the coil assembly to efficiently defrost the coil.
Once the heater is carefully slipped down and out of the evaporation coil, replace the heater element with the new one by feeding the wires bac
This requires the removal of all the shelves, ice maker, and all the covers in the freezer section to expose the evaporation coil.
The defrost heater wraps around the outside edges of the evaporation coil. The heater is suppose to come on for 20 minutes every 8 hours to keep the evaporation coil from becoming covered with frost which will prevent the air from circulating into the refrigerator section.
I found where the heater leads plug into the back wall of the freezer and with the power on and in the defrost cycle (turn or index the timer around with the large screw driver until the compressor cuts off again). Carefully read across these two heater leads and check for 120 VAC. Noting there was 120vac across these two leads I then turned the refrigerator off and unplugged the refrigerator from the wall.
Now with the Volt Meter set to the Ohms setting I unplugged the two heater leads with the needle nose pliers and read the ohm value across the two wire leads of the heater element. (I got lucky and found a schematic folded up and stuck just behind the front grill at the bottom of the freezer). The schematic told me the ohm value should have been 22 ohms. However, my value was 0 ohms this told me the heater had an open circuit (it had a broken wire inside the heater element). I located the correct part using the model # on the Part Select website and ordered the defrost heater element for my model refrigerator. I received the part in three days.
Now for the fun part, of removing and installing the new element.
This is not brain surgery but … it is not for the faint at heart either, you must be able to work in tight areas and be agile enough to sit on the floor while reaching the back of the freezer and be patient and deliberate with your moves. (kind of like playing the Milton Bradley game “Operation” as a kid)
Next step is to remove the two top screws holding the evaporation coil to the back of the freezer, then remove the cover to expose the refrigerant lines inside the freezer, remove the two foam side supports holding the coil centered in the back of the freezer and then VERY carefully lift the evaporation coil straight up to un- hook it from the bottom clips which hold the bottom of the coil stationary. Then gently remove the two aluminum side plates from the coil by bending the tabs that hook these plates to the curved refrigerant coils they are hooked around. With the side plates removed then carefully un- hook the 4 clips which hold the heater in place around the evaporation coil. Using a pair of needle nose pliers unplug the heater leads from the back wall contact point (Remember to be sure and unplug refrigerator before doing this) At this point VERY carefully lift up slightly and gently pull the bottom of the coil out (trying to keep the top of the coil at the same elevation and parallel to the back wall pull the bottom out to a point where the heater element can be slid down and out of the evaporation coil as it is basically woven thru the coil assembly to efficiently defrost the coil.
Once the heater is carefully slipped down and out of the evaporation coil, replace the heater element with the new one by feeding the wires bac
Read less
Was this helpful?
Thank you for voting!
Chirping sound coming from the freezer-old gasket on food door causing air leakage r
10 of 17 people
found this instruction helpful.
-
JAMES from WAUPACA, WI
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Removed shelving,ice maker & other air deverters to get at fan motor. Disconnected power, then removed motor by removing screws holding motor assembly in place. Push fan blade on to motor reconnect wiring.
Chirping stopped and ice cream is now rock hard.
Food door gasket was more time consuming than hard. Loosen old ... Read more gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Chirping stopped and ice cream is now rock hard.
Food door gasket was more time consuming than hard. Loosen old ... Read more gasket screws with not driver. Gasket is then easily removed. Reinstall gasket, but keep retaining strips loose so you can adjust gasket for a correct fit.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people
found this instruction helpful.
-
Peter from Herndon, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people
found this instruction helpful.
-
David from Choctaw, OK
- Easy
- 30 - 60 mins
-
Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin
... Read more
g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Read less
Was this helpful?
Thank you for voting!
Ice maker stopped working after less than six months
8 of 13 people
found this instruction helpful.
-
Claude from Oakdale, CA
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
After checking all connections I determined the ice maker which had been replaced on 01/2007 stopped making ice. I had serviceman from a local company return and check the ice maker. He rinsed the ice maker under warm water, melting the ice build-up and re-installed the ice maker. I watched him do the re-installation, then waited for two
... Read more
days to see if the ice maker was functioning. Since the ice maker wasn't working, I called the serviceman, who in turn informed me that the replacement ice maker had increased in price from $170.00 to $274.00. That is when I contacted your web site, ordered the replacement ice maker.
I was totally amazed and pleased by the fast,
easy, and efficient way my order was processed and the ice maker was delivered.
I followed the instructions included with the ice maker, and installed the replacement ice maker in about 20 minutes. I can't thank you enough for the great service. I only wish I had checked my computer after the first ice maker broke down and found your web site.
I was totally amazed and pleased by the fast,
easy, and efficient way my order was processed and the ice maker was delivered.
I followed the instructions included with the ice maker, and installed the replacement ice maker in about 20 minutes. I can't thank you enough for the great service. I only wish I had checked my computer after the first ice maker broke down and found your web site.
Read less
Was this helpful?
Thank you for voting!
No tempersture control, it was either onand freezing or off and hot.
7 of 10 people
found this instruction helpful.
-
loy from Pahrump, NV
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
A simple job to remove the plastic cover held by two screws. Then one screw which held the old controller frame. Then remove two screws which held controller. Putting it back was just the reverse.
I did not have to adjust the new control position but with the wrench in the kit it would have been no trouble to do that either.
... Read more > The instructions were just fine and anyone with a little mechanical knowledge could do it
I did not have to adjust the new control position but with the wrench in the kit it would have been no trouble to do that either.
... Read more > The instructions were just fine and anyone with a little mechanical knowledge could do it
Read less
Was this helpful?
Thank you for voting!
Light switch broke on refridgerator door.
10 of 19 people
found this instruction helpful.
-
Darlene from Holland, MI
- Really Easy
- 15 - 30 mins
-
Screw drivers
I measured the part then looked for a similar switch that might work. I was so happy to find the exact part we needed for our 24 year old refridgerator!! I was so impressed with your slection of parts and best of all I had the part in 2 days! You are in my "favorites" just in case I need you again!
Thank you
Thank you
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people
found this instruction helpful.
-
Antonio from San Antonio, TX
- Really Easy
- Less than 15 mins
-
Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
Refrig Door Cams wore out and made noises when opening and closing.
6 of 7 people
found this instruction helpful.
-
Michael from Lewisville, TX
- Easy
- Less than 15 mins
-
Pliers, Socket set
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two y
... Read more
ear old Frig. This is a design problem, as the cams should last longer than 22 months.
Read less
Was this helpful?
Thank you for voting!
Ice maker would not work.
6 of 7 people
found this instruction helpful.
-
Ed from Glendora, CA
- A Bit Difficult
- 1- 2 hours
-
Nutdriver
I replaced the dual outlet valve and deiced the filler tube going to the ice maker. I removed the filler tube and ran hot water on it. I believe the old filler valve was leaking letting water slowly into the filler tube where it eventually froze solid.
Was this helpful?
Thank you for voting!
In the ice storm in bootheel of Mo the power spiked a few times before it went off. When power came back on, my frige wouldn't stay working. I would have to touch the thermostat to make it cycle back on. Found exact parts on line at partselect needed to repair the fridge. thanks guys!
6 of 8 people
found this instruction helpful.
-
George from Gideon, MO
- Easy
- Less than 15 mins
-
Nutdriver
First I unplugged the appliance, then I took the two screws out that hold the cover over the temp. control knobs,then I removed the cover from the fan and thermocouple probe end. Then I unplugged the two hot wires from the thermostat,and then the ground wire. Then removed the two screws holding the thermostat in place and removed old ther
... Read more
mostat. Installed new thermostat following steps in reverse order.
Read less
Was this helpful?
Thank you for voting!
stop making ice
7 of 11 people
found this instruction helpful.
-
Ricky from Philadelphia, PA
- Easy
- Less than 15 mins
-
Nutdriver
1.removed 3 nut screws-2 on top &1 on bottom.
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in ... Read more about 2-3 hours
2.unplug ref. from outlet.
3.unplug the wires from ice maker to ref.
4.remove ice maker
5.rinse new ice maker
6.plug ice maker to ref. using included wires
7.screw 2 top nut screws first then the bottom.
8.plug ref. back to outlet
9.made first ice in ... Read more about 2-3 hours
Read less
Was this helpful?
Thank you for voting!
Refrigerator water nozzle broke
5 of 5 people
found this instruction helpful.
-
Sandra from RESTON, VA
- Really Easy
- Less than 15 mins
-
Screw drivers
The nozzle of the water dispenser broke. I ordered the part which arrived the next day. I did not use the white line, only the black. I turned the water off, then I removed the screw under the broken nozzle and cut off it off from the line. I took a new screw and cut off the top with pliers, then twisted half of a screw in the old li
... Read more
ne and inserted the other half in the new line and pulled the line from the bottom corner of the refrigerator and connected it to the white line under the grid. Screwed the new nozzle back to the lever, replaced the grid and turned water on.
Read less
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people
found this instruction helpful.
-
Duncan from Metairie, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?