1068612 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people
found this instruction helpful.
-
Florentino from Windsor Locks, CT
- Easy
- 30 - 60 mins
-
Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people
found this instruction helpful.
-
W from Nellysford, VA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns
... Read more
crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Read less
Was this helpful?
Thank you for voting!
Just a trickle of water to icemaker and water dispenser
22 of 24 people
found this instruction helpful.
-
Bill from Hot Springs Village, AR
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
Turned refrig off, pulled it out for access to the valve, unplugged refrig and turned off water supply to the outlet valve. I made the installation a bit more difficult by over tightening the supply line connection which ruined the brass compression washer. I replaced it with a plastic compression washer which is probably better since t
... Read more
he supply line is plastic. The electrical connections were very simple. I was just guessing the old outlet valve was bad since I had checked the filter. After replacing the valve, the ice maker and water dispenser work like new on a 17 year old refrigeration. Also, I was very pleased with fast processing and delivery of the order.
Read less
Was this helpful?
Thank you for voting!
refrigerator would not keep running.I had to tap the cold control with the blunt end of a knife
23 of 28 people
found this instruction helpful.
-
gary from fort bragg, CA
- Really Easy
- Less than 15 mins
-
Nutdriver
first I unpluged the refrigerator, then removed the nob for the cold control thermostat. then I removed the plastic cover, and removed the lightbulb. this revealed the metal plate that holds the cold control. four screws held this in place.once theplate was loose I unpluged the three wires that plug into the cold control, and removed the
... Read more
two srews that held it in place. then I remved the cold control thermostat, replaced it with the new one hooked up the wires, replaced the metal plate and lightbulb,and the plastic cover. plugged the refrigerator back in, and turned it back on works great now. I hope this will help others to make their repairs easier thanks, gary
Read less
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people
found this instruction helpful.
-
Bob from Hesston, KS
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova
... Read more
l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Read less
Was this helpful?
Thank you for voting!
The old resevoir needed to be replaced
35 of 68 people
found this instruction helpful.
-
Fred from Martinsburg, WV
- Really Easy
- 15 - 30 mins
-
Pliers, Socket set
The repair was incredibly easy -
1. Turn off the water at the water line for the fridge
2. Disconnect the pressure fittings for both lines running to the resevoir.
3. Remove the old resevoir
4. Install the new resevoir and run the lines back to the orginal fittings.
5. Reconnect the fittings, turn on water.< ... Read more br />6. Drink water!
1. Turn off the water at the water line for the fridge
2. Disconnect the pressure fittings for both lines running to the resevoir.
3. Remove the old resevoir
4. Install the new resevoir and run the lines back to the orginal fittings.
5. Reconnect the fittings, turn on water.< ... Read more br />6. Drink water!
Read less
Was this helpful?
Thank you for voting!
Ice maker water outlet freezes and prevents flow
20 of 26 people
found this instruction helpful.
-
Alexander from Miami, FL
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Socket set, Wrench (Adjustable), Wrench set
Get refrigerator out away from the wall. Disconnect from power. Loosen 3 and remove 3 or 4 screws to uncover fan, compressor and water inlet valve (WIV). By hand remove plastic hoses that feed the water dispenser and ice maker feed. Unscrew 2 screws that hold WIV her you need the Spring U Joint (SUJ) or equivalent. Pull wires and make men
... Read more
tal note or picture the way they fit. They retain the memory the way they came out. With adjustable or wrench remove tube that comes from the filter. Remover black rubber protector from WIV. Install the last hose you removed. Tighten by hand and finish with the wrench used to remove it. Don't over tighten. Maybe 3/4 turn or less after hand tight will do. The difficult part is to re-install the screws that hold the WIV in place, again you need the SUJ. The alternative would be to empty the shelves from anything that will spill or break and have someone tilt the refrigerator and access from below. I used the 1st method as I didn't have the extra help. Install the water dispenser hose (by hand), blow compressed air to the ice dispenser hose to clear the ice. There is another plastic hose just above and behind the dispenser which must be removed to clear the ice that is being blown. After the ice is clear re-install the one in the freezer. That one is just pressure held be careful not to break when replacing it. Re-install by hand the ice dispenser hose to the WIV. Replace the cardboard cover that was 1st removed to access the components. Power the refrigerator and you are ready to make fresh ice. My ice maker lever was stuck at 1st. I released pressure from the metal wire lever and wiggled up and down several times to loosen up.
Read less
Was this helpful?
Thank you for voting!
freezer making a squealing sound
17 of 20 people
found this instruction helpful.
-
PAUL from Boiling Springs, SC
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
First I Removed the racks. Next 3 hex bolts that secured the ice maker. Undid the ponytail wiring. 3 Phillips screws to remove the metal back. unplugged the Evaporator Fan Motor. Replaced the new one. reassembled.
Was this helpful?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
21 of 32 people
found this instruction helpful.
-
jesse from hacienda heights, CA
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Was this helpful?
Thank you for voting!
Squealing evaporator fan
15 of 18 people
found this instruction helpful.
-
JOHN from BEAVER, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
Unplugged the fridge, emptied the freezer, removed the panel screws, removed the fan assembly retaining nuts, slid the spade wire connectors from the tabs, and performed these tasks in reverse to have the fridge up and running like new. I am not an appliance repair person, but I am not intimidated by simple repairs. Your instructions wer
... Read more
e easy to follow, and the cry in the kitchen of "we need a new refrigerator" was silenced for less than $50.00. Thanks!
Read less
Was this helpful?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people
found this instruction helpful.
-
David from Cedarville, OH
- A Bit Difficult
- More than 2 hours
-
Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people
found this instruction helpful.
-
bill from escondido, CA
- Easy
- 15 - 30 mins
-
Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
The Ice maker would not work.
22 of 42 people
found this instruction helpful.
-
Jerry from Boulder, CO
- Easy
- 1- 2 hours
-
Screw drivers
We rolled the refrigerator out away from the wall and it was obvious where the break was located. We took out the old water spout for the ice maker and replaced the tube and the tubing from the solenoid. We turned it on and soon we had water dripping everywhere. We unloaded and defrosted the freezer which got all of the remaining ice th
... Read more
at was stuck in there. We put everything back together. I read in some instructions in the manual that it might take 24 hours for the ice maker to reprogram itself and start producing ice. I was only about 12 hours and we had ice again and everything worked well. You really do not have to disconnect the water from the main line, the solinoid controls that part of operation and turns the water off until the ice trays are free and clear.
JLB
JLB
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator quit refrigerating
15 of 21 people
found this instruction helpful.
-
William from Hudson, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Read less
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people
found this instruction helpful.
-
David from Arnold, ME
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!