fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
Our ice maker did not work.
10 of 15 people found this instruction helpful.
  • Jay from Flower Mound, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Socket set
I turned off the water supply and disconnected the power. Then I removed the back cover plate and the two water lines. Fortunately the water lines are a different size so it is not confusing which line goes on each outlet. Then I loosened the two screws that fasten the valve assembly. It requires a nut driver with a flexible drive or a 1/4" socket set with a "U" joint. We were then able to disconnect the third water line on the back side of the valve assembly. I then reversed the sequence to install the new valve. The only difficulty is getting the screws started on the valve assembly.
The trouble shooting guide in the Kitchen-aid user manual is totally inadequate. I bought and replaced the whole icemaker unit when all I needed was the valve.
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Would restart when thermostat was tapped, but would stop again within minutes.
8 of 9 people found this instruction helpful.
  • Charles from Chatsworth, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Instructions were simple and clear. Removed knob, snapped off plastic control panel. Then removed five 1/4" head sheetmetal screws to remove metal bracket holding thermostat. Two more 1/4" head screws held the thermostat to the bracket. Then pulled off the three fast-on electrical connections and pulled the thermostat and thermocouple tube out. Reversed the process to install new thermostat. My 33 year old garage refrigerator now works perfectly again! NOTE: searching for "thermostat" on the site didn't work.. It's called a "cold control thermostat" for some reason. That's redundant; other than cold, why would a themostat be in a refigerator, for heaven's sakes!?
Was this helpful?
Thank you for voting!
35 year old water tube became brittle and cracked; leaking water
8 of 10 people found this instruction helpful.
  • Melvin from OPELIKA, AL
  • Very Easy
  • Less than 15 mins
  • Screw drivers
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Was this helpful?
Thank you for voting!
The fan quit
11 of 19 people found this instruction helpful.
  • donn from Ranier, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I took the old one out and put the new one in. EASY!
Was this helpful?
Thank you for voting!
Ice getting stuck, and water flowing over everything
7 of 7 people found this instruction helpful.
  • Randal from Wakefield, RI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Was this helpful?
Thank you for voting!
ice maker leaking or overflowing into ice bend
9 of 13 people found this instruction helpful.
  • LARRY from DYER, TN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Wrench set
first bought new ice maker installed it-didn`t fix the problem. next bought fill tube kit and dual outlet vale -installed those ice maker works GREAT no leaks -no ice froze together in bend. thanks for the help GUYS.
Was this helpful?
Thank you for voting!
Icemaker not working
7 of 8 people found this instruction helpful.
  • Hal from Virginia Beach, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Started the replacement of the existing dual outlet valve by removing cardboard covering the lower back of the refrigerator exposing the outlet valve. Closed the water supply valve at the wall. Removed the hose bibb water supply connection on the outlet valve by hand as it is only hand-tight. I used a small plastic container to catch the minimal amount of water left in the copper line. I removed the electrical connection on each solenoid valve (one for the in-door water supply and one for the icemaker supply). I removed the plastic supply lines from the outlet valve. I removed the screws on the bracket attaching the dual outlet valve to the refrigerator vertical rail. I reconnected the electrical connectors to the valve. I reattached the plastic supply lines to the valve, but did not tighten them fully at this point. I secured the bracket on the new valve to the existing screwholes on the refrigerator rail. The new outlet valve does not have a hose bibb connector, it has a compression fitting for the supply. I reused the existing copper supply line from the wall angle-stop valve to reconnect to the new outlet valve. (It would have been best to have cut the copper line and used a new furrel on the copper line). Note that the supply line now comes into the outlet valve from the top, not the rear as on the old valve, so now the dual outlet valve sticks out beyond the frame of the refrigerator. I tightened the nuts on the plastic supply lines on the valve. I had to cut the cardboard cover around the new outlet valve. Resecured the cardboard cover to the back of the frig. Checked for leaks, turned the icemaker on by lowering the shutoff arm, and after a few moments, the outlet valve opened, water flowed into the icemaker, and all is well.
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
Refrig Door Cams wore out and made noises when opening and closing.
6 of 7 people found this instruction helpful.
  • Michael from Lewisville, TX
  • Easy
  • Less than 15 mins
  • Pliers, Socket set
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two y ear old Frig. This is a design problem, as the cams should last longer than 22 months.
Was this helpful?
Thank you for voting!
No tempersture control, it was either onand freezing or off and hot.
7 of 10 people found this instruction helpful.
  • loy from Pahrump, NV
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
A simple job to remove the plastic cover held by two screws. Then one screw which held the old controller frame. Then remove two screws which held controller. Putting it back was just the reverse.
I did not have to adjust the new control position but with the wrench in the kit it would have been no trouble to do that either. ... Read more > The instructions were just fine and anyone with a little mechanical knowledge could do it
Was this helpful?
Thank you for voting!
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
7 of 10 people found this instruction helpful.
  • Antonio from San Antonio, TX
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
Ice maker stopped working after less than six months
8 of 13 people found this instruction helpful.
  • Claude from Oakdale, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After checking all connections I determined the ice maker which had been replaced on 01/2007 stopped making ice. I had serviceman from a local company return and check the ice maker. He rinsed the ice maker under warm water, melting the ice build-up and re-installed the ice maker. I watched him do the re-installation, then waited for two days to see if the ice maker was functioning. Since the ice maker wasn't working, I called the serviceman, who in turn informed me that the replacement ice maker had increased in price from $170.00 to $274.00. That is when I contacted your web site, ordered the replacement ice maker.
I was totally amazed and pleased by the fast,
easy, and efficient way my order was processed and the ice maker was delivered.
I followed the instructions included with the ice maker, and installed the replacement ice maker in about 20 minutes. I can't thank you enough for the great service. I only wish I had checked my computer after the first ice maker broke down and found your web site.
Was this helpful?
Thank you for voting!