Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people found this instruction helpful.
  • Florentino from Windsor Locks, CT
  • Easy
  • 30 - 60 mins
  • Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Cracked Evaporation tray was leaking water on kitchen floor
26 of 34 people found this instruction helpful.
  • Jerrel from REDDING, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench (Adjustable)
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
Was this helpful?
Thank you for voting!
plastic gear broke off - cubes not getting kicked out
23 of 25 people found this instruction helpful.
  • Laurence from Middleton, WI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
removed the three screw holding the broken unit - pulled off the old module.

Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.

Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people found this instruction helpful.
  • W from Nellysford, VA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Was this helpful?
Thank you for voting!
Fridge side freezing everything.
21 of 22 people found this instruction helpful.
  • David from Murfreesboro, TN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control bo x to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
Was this helpful?
Thank you for voting!
Refrigerator came with house my daughter purchased and needed new seals. Refrigerator is 17 years old.
23 of 28 people found this instruction helpful.
  • Barb from North Royalton, OH
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver
First, I read your instructions on line about how to replace a refrigerator gasket and freezer gasket. We replaced both. The information was extremely helpful since we had never done this before. We then loosed a few screws at a time starting with the outside door corner and worked our way around, replacing the seal as we took off the old seal. Leaving the old seal on as we worked our way around gave us the clearance we needed to insert the new gasket behind the metal plate which holds the gasket to the door. Your easy to use web site made ordering easy and delivery was unbelievably fast. Thanks.
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people found this instruction helpful.
  • Bob from Hesston, KS
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Was this helpful?
Thank you for voting!
refrigerator would not stay cold
21 of 26 people found this instruction helpful.
  • Allan from Allen, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
Was this helpful?
Thank you for voting!
greezer started to thaw and would not refreeze
21 of 27 people found this instruction helpful.
  • Christopher from Redmond, WA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
tested thermostat and defrost time but both tested as working...called a repairman who came in and said they were both working...got annnoyed for not trusting myself. Repairman did say that he had seen defrost timers simply slow down, allwoing them to tesat as good but not actually working correctly. I ordered both the thermostat and the timer to cover all bases...actual replacement was simple.
Was this helpful?
Thank you for voting!
ice would not fall from ice maker
22 of 30 people found this instruction helpful.
  • Greg from Cary, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
Was this helpful?
Thank you for voting!
Refrigerator stop working
23 of 33 people found this instruction helpful.
  • SAL from UPLAND, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First I removed the relay and over load and exam. Saw that the relay was burnt. Before I order the part I check to see if the compressor was still working by jumping the common start and run terminals.It did. I also checked the start capacitor with a capacitor tester it was good. I than order the part which came the very next day.Installe d the part
Was this helpful?
Thank you for voting!
Over flowing Icemaker
21 of 29 people found this instruction helpful.
  • Thomas from Flower Mound, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray.
After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later.
Over flowed and iceberg would form at rear.
Replaced icemaker unit and works fine now.
Was this helpful?
Thank you for voting!
Water leaking from under refrigerator.
17 of 18 people found this instruction helpful.
  • Ronald from DELRAN, NJ
  • Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for le ak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
Was this helpful?
Thank you for voting!
Unable to set the cold-control to a sufficiently cold setting.
36 of 75 people found this instruction helpful.
  • Leo from Lewisport, KY
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now .
Was this helpful?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
21 of 32 people found this instruction helpful.
  • jesse from hacienda heights, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Was this helpful?
Thank you for voting!
All Instructions for the 1068590413
46 - 60 of 1190