wasn't making ice. The ice bin actually filled up with water.
5 of 6 people found this instruction helpful.
  • Bob from Middlefield, CT
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the r efrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Was this helpful?
Thank you for voting!
The icemaker in my freezer stopped producing ice
5 of 7 people found this instruction helpful.
  • Edward from Annapolis, MD
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
1. Removed the icemaker door
2. Removed the two screws from the underside of the icemaker unit
3. Removed the slide-on plastic cover that protects the power cable connector
4. Removed the icemaker unit
5. Removed the two screws from the control unit
6. Pulled the control unit from the icemaker unit
7. Installed the new control unit and reinstalled the icemaker assembly

A repairman wanted to charge me $250 to do what I did in about 20 minutes for about $120.
Was this helpful?
Thank you for voting!
3 inches of frost in Fridge, 72 degrees in Fridgerator
6 of 10 people found this instruction helpful.
  • Gerald from Orangeburg, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Was this helpful?
Thank you for voting!
Refrigerator light would not stay on
4 of 4 people found this instruction helpful.
  • Dave from Manchester Center, VT
  • Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Was this helpful?
Thank you for voting!
Water Fill Cup Broke
5 of 7 people found this instruction helpful.
  • Sam from Las Vegas, NV
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Was this helpful?
Thank you for voting!
Freezer making loud whining noise-Fridge not cooling well
7 of 13 people found this instruction helpful.
  • Dale from Blaine, MN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was befo re. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this helpful?
Thank you for voting!
water was leaking under the frig ,wasnt sure what the problem
4 of 4 people found this instruction helpful.
  • stephen from ROCKLEDGE, PA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
decided to take a chance and replace the ice maker,so far no water leaking.feels nice to know the problem is fixed.thanks for the video on how to replace it, thanks again very easy repair
Was this helpful?
Thank you for voting!
Bad module on icemaker
4 of 4 people found this instruction helpful.
  • Randy from LAFAYETTE, LA
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
First shut off water supply and unplug power. Unscrew icemaker assembly from side wall with 3 screws. Remove front cap and you can clearly see module. Unscrew and remove module ( only three screws). Install new module and revers procedure to finish up. Ice was ready in just a few hours. Video provided by this site was right on and left no questions.
Was this helpful?
Thank you for voting!
Removed the old parts then connected the new parts.
4 of 4 people found this instruction helpful.
  • Jonathan from OLIVE BRANCH, MS
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
The compressor immediately started when I plugged the refrigerator back in. Around 24 hours later the freezer compartment was at 0 degrees, and the refrigerator was at 35 degrees.
Was this helpful?
Thank you for voting!
My U-line ice maker quit filling.
5 of 7 people found this instruction helpful.
  • Anne from Arlington, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bra cket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Was this helpful?
Thank you for voting!
Lost shelf support bracket
4 of 4 people found this instruction helpful.
  • DAVID from LAFAYETTE, LA
  • Really Easy
  • Less than 15 mins
Ordered shelf support stud kit. Product was promptly delivered, and contained the parts as shown on website. Took longer to open the package than to replace the missing shelf support bracket. No problems. Would order from them again.
Was this helpful?
Thank you for voting!
Making a god awful racket.
5 of 7 people found this instruction helpful.
  • Michael from Locust Grove, VA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Ok its the garage "adult " Beverage chiller.

Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this helpful?
Thank you for voting!
Ice maker was leaking
6 of 10 people found this instruction helpful.
  • Thomas from San Diego, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
This is an incredibly easy repair.

1) Remove the three screws holding the old icemaker

2) Disconnect the electrical connection (I used a spoon to get in and undo the connector clip

Do the opposite to install the new icemaker.

Total elapsed time was about 5 minutes.
Was this helpful?
Thank you for voting!
Light in my refrigerator didn't work.
5 of 7 people found this instruction helpful.
  • Joseph from Byron Center, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved m e $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.
Was this helpful?
Thank you for voting!
Evaporator Fan in Freezer Making Load Noise
4 of 5 people found this instruction helpful.
  • Ralph from SAINT PAUL, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.