Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people
found this instruction helpful.
-
Florentino from Windsor Locks, CT
- Easy
- 30 - 60 mins
-
Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people
found this instruction helpful.
-
W from Nellysford, VA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns
... Read more
crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Read less
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people
found this instruction helpful.
-
Bob from Hesston, KS
- Easy
- 15 - 30 mins
-
Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova
... Read more
l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Read less
Was this helpful?
Thank you for voting!
compressor didnt turn on
24 of 41 people
found this instruction helpful.
-
gerardo from el monte, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
changed the starter connected to the compressor
Was this helpful?
Thank you for voting!
Door not swinging freely and not closing automatically
15 of 18 people
found this instruction helpful.
-
Harold from Sun City, CA
- Really Easy
- 30 - 60 mins
-
Socket set
replaced lower door closing cams and shim and cleanded and lubricated top and bottom hinge. Took about 30 minutes. Hardest part was unloading the door and finding a place to put all the bottles and stuff. Door works just fine now.
Other Parts Used:
Was this helpful?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
14 of 16 people
found this instruction helpful.
-
David from Cedarville, OH
- A Bit Difficult
- More than 2 hours
-
Screw drivers, Socket set
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Was this helpful?
Thank you for voting!
Unit Was Not Self Defrosting
15 of 19 people
found this instruction helpful.
-
mary from lodi, NJ
- Really Easy
- 15 - 30 mins
-
Screw drivers
A very easy job. Heater was broken and needed to be replaced and since the freezer was over 30 years old I also replaced the timer. Now the freezer is good for another 30 years thanks to parts silect and there speedy shipment of my parts
Other Parts Used:
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people
found this instruction helpful.
-
bill from escondido, CA
- Easy
- 15 - 30 mins
-
Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
My Fan in the Freezer was making a loud noise
15 of 21 people
found this instruction helpful.
-
Michael from Imperial, MO
- A Bit Difficult
- 1- 2 hours
-
Screw drivers
I went on the web to search for parts, did my screening of companies, and chose Partselect.com
They gave me accurate information, very nice, and double checked the part numbers, and the latest replacement part. I received it in a couple of days, followed the directions, and it's working just fine! I saved a lot of money through Parts ... Read more elect, instead of buying a new refrigerator.
NICE JOB Partselect!!
Thanks,
Michael
They gave me accurate information, very nice, and double checked the part numbers, and the latest replacement part. I received it in a couple of days, followed the directions, and it's working just fine! I saved a lot of money through Parts ... Read more elect, instead of buying a new refrigerator.
NICE JOB Partselect!!
Thanks,
Michael
Read less
Was this helpful?
Thank you for voting!
Refrigerator quit refrigerating
15 of 21 people
found this instruction helpful.
-
William from Hudson, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Read less
Was this helpful?
Thank you for voting!
The refrigerator door made a terrible bang every time it was opened.
13 of 15 people
found this instruction helpful.
-
Hank from Seattle, WA
- Really Easy
- 15 - 30 mins
-
Nutdriver
The hardest part was unloading all the food from the refridgerator door! Once done, pry shroud off top door hinge, remove 3 screws and hinge plate. Lift door off bottom hinge. Remove one screw from bottom of door, remove and discard old lifter cam and spacer. Clean up a bit. Install new spacer and lifter cam. Tighten new screw firml
... Read more
y. Replace the lifter cam and spacer on bottom hinge pin (affixed to refridgerator body) using the same method. Replacing the door is easiest if 2 people do it. One person to lift and steady the door, the other has to lie on the floor and guide the door onto the hinge pin. Replace top hinge plate and screws. Snap shroud back over top hinge plate. Replace food in refridgerator. Close door. Done!
Read less
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people
found this instruction helpful.
-
David from Arnold, ME
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!
The old door gasket was hard and frequently didn't seal and caused evaperator to ice up and contents of freezer to thaw out.
12 of 13 people
found this instruction helpful.
-
Vernon from Clayton, NC
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver
Using a nut driver on a cordless drill I took out the screws that held the metal strips on, which held the seal in place. I installed the new seal with a hand driven nut driver so as not to strip the screw holes in the door. It came out well and the new seal works very well. Getting the seal positioned properly was the most tedious par
... Read more
t.
Read less
Was this helpful?
Thank you for voting!
Old Door Gasket had been destroyed by animals while in storage
13 of 17 people
found this instruction helpful.
-
Peter from Gloucester, MA
- Easy
- 30 - 60 mins
-
Nutdriver
I removed all of the nuts around the door that held the gasket on, removed the old gasket, and then placed the new gasket on the door. Easy as pie! No special skills or knowledge required. Just a little patience to make sure the new gasket is sitting properly on the door before the nuts are tightened.
Was this helpful?
Thank you for voting!
Noise coming from defrost timer
12 of 14 people
found this instruction helpful.
-
Thomas from Pottstown, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in
... Read more
the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Read less
Was this helpful?
Thank you for voting!