socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people found this instruction helpful.
  • George from Glenwood, MN
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Was this helpful?
Thank you for voting!
The fan quit
11 of 19 people found this instruction helpful.
  • donn from Ranier, MN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I took the old one out and put the new one in. EASY!
Was this helpful?
Thank you for voting!
fan not working
7 of 9 people found this instruction helpful.
  • Gary from Erving, MA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
unpluged unit, removed 2 panel screws, removed 4 fan screws, disconnected wires, reassembled
Was this helpful?
Thank you for voting!
fan made lots of noise
7 of 9 people found this instruction helpful.
  • jim from bedford, KY
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
unplugged refrig.
removed screws on back panel of freezer compartment

removed fan motor cover

removed fan

broke ends off support bracket in accordance with directions

had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan

plugge d all 3 wires into fan motor

replaced covers

every thing works fine now.

part was delivered quite promptly

refrigerator was over 30 years old and a sears model but mfg by whirlpool
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
Refrig Door Cams wore out and made noises when opening and closing.
6 of 7 people found this instruction helpful.
  • Michael from Lewisville, TX
  • Easy
  • Less than 15 mins
  • Pliers, Socket set
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two y ear old Frig. This is a design problem, as the cams should last longer than 22 months.
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people found this instruction helpful.
  • Ronald from Martinsville, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
door would not stay closed
5 of 5 people found this instruction helpful.
  • David from Chagrin falls, OH
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
Removed the top plastic hinge cover, remove (2) bolts from top hinge. Lifted door up and off of lower hinge, removed both halves of door cam, replaced cam halves and re-installed door. Super easy and effective. Door now opens and closes (stays closed) properly.
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people found this instruction helpful.
  • Carl from RIVERSIDE, CA
  • Very Difficult
  • More than 2 hours
  • Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!