My refrigerator ran constantly and never got cold!
11 of 12 people found this instruction helpful.
  • Brandon from Fort Wayne, IN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
On a whim I looked into what it would take to fix my garage older 2nd fridge. I was thinking I needed a new seal, but when I checked the website there was a great troubleshooter. I would have never guessed that the defrost timer was what would cause it not to ever get cold. After a fairly simple repair the freezer is colder than ever a nd I actually had to turn it down. The only complication was the fridge was stuck in a defrost cycle so I had to reset the timer to get the refrigerator running. Thanks so much for a super helpful site for a do-it-yourselfer like me.
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people found this instruction helpful.
  • Maxine from Birmingham, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
No water to the ice maker
11 of 13 people found this instruction helpful.
  • Ron from Ferndale, WA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I s ent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.

Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Was this helpful?
Thank you for voting!
installed ice maker
13 of 19 people found this instruction helpful.
  • Dennis from Spring Valley, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers, Wrench set
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small p ierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
Was this helpful?
Thank you for voting!
Loud noise
11 of 13 people found this instruction helpful.
  • Britney from Wilmington, OH
  • Easy
  • 15 - 30 mins
  • Socket set
There was a loud noise coming from the fridge - we ordered the new part it came a lot sooner than we excepted and we replaced it in about 20 minutes- the hardest part was my husband getting his hand in there to put the screws in- but a very easy fix.
Was this helpful?
Thank you for voting!
Didn't know if I needed Left or Right.
11 of 14 people found this instruction helpful.
  • Joyce from Kerrville, TX
  • Really Easy
  • Less than 15 mins
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people found this instruction helpful.
  • martin l. from JACKSONVILLE,, IL
  • Really Easy
  • Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people found this instruction helpful.
  • Steven from Brigham City, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people found this instruction helpful.
  • Benjamin from Daytona Beach, FL
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot al time of ice maker water leak repair and fan replacement about 1 hour.
Was this helpful?
Thank you for voting!
Ice maker stopped working
9 of 9 people found this instruction helpful.
  • Martin from DESOTO, TX
  • Really Easy
  • 30 - 60 mins
  • Nutdriver
Our ice maker had been overfilling and causing a big block of ice in the bin for some time, but it finally stopped working completely. In trying to determine the problem, I read the comments on the PartSelect website from other customers and thought I needed either a new valve or a new ice maker. I replaced both because when I took the old ice maker out, it had a lot of mineral deposits in it and looked very unappetizing. The videos on how to replace the valve and ice maker were very helpful. Other customers comments on replacing the valve were also great. The only thing I would add is that after getting the parts installed and the water line and electricity reconnected, it takes an hour or so for the ice maker to to fill. I suppose there is a temperature sensor that won't fill it until gets down to a certain point. I am very pleased with the outcome of this project on our 28 year old refrigerator.
Was this helpful?
Thank you for voting!
Freezer was working fine but refrigerator would not go below 45 degrees
9 of 9 people found this instruction helpful.
  • Christopher from CASTAIC, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed back panel inside freezer replaced fan motor reinstalled panel and was done in about 40 minutes the video on part select explains the repair very accurately
Was this helpful?
Thank you for voting!
Broken shelf support
9 of 10 people found this instruction helpful.
  • Arthur from West Chicago, IL
  • Really Easy
  • Less than 15 mins
snapped in. The best part was the ease that i identified the part due to your website.
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people found this instruction helpful.
  • Lori from Chuluota, FL
  • Easy
  • Less than 15 mins
  • Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
Freezer working, not cold enough in fridge area.
9 of 10 people found this instruction helpful.
  • Ralph from ALVORD, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
Top freezer, remove fan cover on back panel in side top freezer, remove back panel inside top freezer, remove fan and fan motor, unplug electric from fan (PS unplug fridge first). Install new motor, replace ever thing in reverse. works great.
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people found this instruction helpful.
  • JAMES from Middleboro, MA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Was this helpful?
Thank you for voting!