Ice Maker quit working, I could manually cycle unit but then the water would overflow when unit was re-filling.
596 of 639 people
found this instruction helpful.
-
Max from Green Castle, IN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I backed out the 2 top screws about a quarter inch and then removed bottem screw with a quater inch nut driver. I then lifted Ice Maker clear of the two top screws and lowered it enough to unclip the power connection with a small screwdriver. The new Ice Maker was wired correctley for my refrigeator so all I had to do wea reconnect the
... Read more
power connection and mount new Ice Maker on the two top screws and install the bottem screw. It took e while for the new Ice Maker to start it's cycle but after it did, it worked GREAT. Part Select service was OUTSTANDING, ordered part one day and received the next. THANKS!!!!
Read less
Was this helpful?
Thank you for voting!
No ice
567 of 688 people
found this instruction helpful.
-
Daniel from Suwanee, GA
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Was this helpful?
Thank you for voting!
The frost free feature of the freezer was freezing over with ice and cooling coils were being insulated with thickening frost which caused the cooling air to rise in temperature from -5 degrees to 20 degrees.
430 of 518 people
found this instruction helpful.
-
Lawrence from Grahamsville, NY
- A Bit Difficult
- 1- 2 hours
-
Nutdriver
I troubleshot the problem by reading the electrical schematic and concluding the heating elements (defrost cables) were either defective or the bi-metal temp sensor was open. When closed the temp sensor completes the circuit for the current to flow through the heaters to defrost the cooling coils every 8 hours and then when the bimetal o
... Read more
pens at 55 degrees the circuit is open and the coils are cooled because the refridgeration motor is in run mode. A timer between the motor and heater elements also was defective. The timer controls the cooling period and the defrost period. I ohmed out each part according to the spec sheet of normal resistance of parts and thus the bimetal and timer were defective. I gather a surge of some duration and amplitude affected these parts because a storm 24 hours prior to refridgerator problem had passsed through the area and the AC electrical power had oscillated several times during that event. I used hand tools to do the repair. If you are not mechanically inclined a step by step proceedure would be moot. It is a matter of disassembly and assembly paying close attention to fragile parts.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
My refrigerator stopped cooling and the freezer section stopped freezing
439 of 554 people
found this instruction helpful.
-
garth from forest lake, MN
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck le
... Read more
t's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
Read less
Was this helpful?
Thank you for voting!
We were getting ice forming in the freezer compartment and water in the frig compartment
211 of 238 people
found this instruction helpful.
-
Teri from West Valley City, UT
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers, Socket set
A. remove food from freezer and store in cooler etc.
B. turn off frig with dial in main compartment, then pull frig out away from wall and unplug and remove the cover ( It is located at the bottom of the frig and may be cardboard and contains a handfull of 1/4" screws) exposing the compressor and drain tube (this is a good time to ... Read more vacume the compressor and coil area)
c. Take false back off from freezer by removing two 1/4 inch screws.
Next,
1. we made sure that the drain tube that runs down to a drain pan near the evaporator coil was clear, we did this by using a small aount of rock salt to speed up the melting of the ice then poured small amounts of hot water (boiling into the drain hole and soon the water flowed down the tube and into the pan below.
2. We then pushed a #12 standed electrical wire (with its end stripped back 1-1/2" then folding the strands back to create a broom) down the tube to the pan to push out any debree that may be present i.e. tin foil plastic bag particles, food chunks etc.
Making sure that this drain tube is clear is the first thing that could be causing the ice build up and water in the lower compartment!
However, I performed this several times and didn't change the problem so I chose to change the parts associated with defrost:
1. defrost heater, which is very easy to change. it is mostly plug and play but does require a pair of needle nose pliers to open a couple of metal fins to remove heater from its mounts, just be gentle with the process.
2. defrost thermostat, which is also very easy to change (Simply pull it off of a copper tube) but requires you to cut two wires near the old part and wire nut the new part wires to the remaining original wires, I added some anti oxident to the wires inside the wire nut to prevent a bad connection from developing do to moisture in this area (You can buy wire nuts with this already inside them, do this)and I taped the wire nut with a few inches of ELECTRICAL TAPE CLOSING OFF THE OPENING OF THE WIRE NUT.
You can then put his cabinet back together!
3. I also decided to change the defrost timer which is located inside a cover where the frig temperture setting dial is located. It is held to this cover by two phillips screws the cover is held in place by one 1/4" screw.
once you have the cover off and the defrost timer unscrewed you must remove a plug from the timer!
Now if you got the exact part you simply reinstall the defrost timer plug in the same postion on the new timer and screw the timer back onto its mount etc. However you may need to determine if the new timer is in the "DEFROST" position and you will need to take it out of that position by I assume rotating the timer mechanism (Ask a tech person about this)!!!!!!!!!
Then with all that done plug your frig vack in reposition it turn it on and be proud of yourself.
Now, if you recieved the timer I did it may look the same as the old one, but it may contain a black wire!!!
You will need to know which type of defrost timer application you frig uses:
1. Continuous run
2. version 1 Cumulative compressor run.
or
3. version 2 Cumulative compressor run.
I found a wiring diagram folded up and stored in the grill in the bottom of the front of the frig that helped me determine this. you will need to be able to read a wiring diagram but I found this situation to be simply a matter of matching examples of pictures (line diagrams). It is important though as you must determine which timer application your frig has because the black wire must be placed on a certain terminal for proper operation.
I replaced a three parts and may have, through trouble shooting, been able to save some money by not replacing all these parts. However , I found that when I went for guidance on trouble shooting that i.e. with the heater that ohmic values of the old part may be near the new part that it may still not be conclusive!? so for a hundred bucks my frig may last 5-10
B. turn off frig with dial in main compartment, then pull frig out away from wall and unplug and remove the cover ( It is located at the bottom of the frig and may be cardboard and contains a handfull of 1/4" screws) exposing the compressor and drain tube (this is a good time to ... Read more vacume the compressor and coil area)
c. Take false back off from freezer by removing two 1/4 inch screws.
Next,
1. we made sure that the drain tube that runs down to a drain pan near the evaporator coil was clear, we did this by using a small aount of rock salt to speed up the melting of the ice then poured small amounts of hot water (boiling into the drain hole and soon the water flowed down the tube and into the pan below.
2. We then pushed a #12 standed electrical wire (with its end stripped back 1-1/2" then folding the strands back to create a broom) down the tube to the pan to push out any debree that may be present i.e. tin foil plastic bag particles, food chunks etc.
Making sure that this drain tube is clear is the first thing that could be causing the ice build up and water in the lower compartment!
However, I performed this several times and didn't change the problem so I chose to change the parts associated with defrost:
1. defrost heater, which is very easy to change. it is mostly plug and play but does require a pair of needle nose pliers to open a couple of metal fins to remove heater from its mounts, just be gentle with the process.
2. defrost thermostat, which is also very easy to change (Simply pull it off of a copper tube) but requires you to cut two wires near the old part and wire nut the new part wires to the remaining original wires, I added some anti oxident to the wires inside the wire nut to prevent a bad connection from developing do to moisture in this area (You can buy wire nuts with this already inside them, do this)and I taped the wire nut with a few inches of ELECTRICAL TAPE CLOSING OFF THE OPENING OF THE WIRE NUT.
You can then put his cabinet back together!
3. I also decided to change the defrost timer which is located inside a cover where the frig temperture setting dial is located. It is held to this cover by two phillips screws the cover is held in place by one 1/4" screw.
once you have the cover off and the defrost timer unscrewed you must remove a plug from the timer!
Now if you got the exact part you simply reinstall the defrost timer plug in the same postion on the new timer and screw the timer back onto its mount etc. However you may need to determine if the new timer is in the "DEFROST" position and you will need to take it out of that position by I assume rotating the timer mechanism (Ask a tech person about this)!!!!!!!!!
Then with all that done plug your frig vack in reposition it turn it on and be proud of yourself.
Now, if you recieved the timer I did it may look the same as the old one, but it may contain a black wire!!!
You will need to know which type of defrost timer application you frig uses:
1. Continuous run
2. version 1 Cumulative compressor run.
or
3. version 2 Cumulative compressor run.
I found a wiring diagram folded up and stored in the grill in the bottom of the front of the frig that helped me determine this. you will need to be able to read a wiring diagram but I found this situation to be simply a matter of matching examples of pictures (line diagrams). It is important though as you must determine which timer application your frig has because the black wire must be placed on a certain terminal for proper operation.
I replaced a three parts and may have, through trouble shooting, been able to save some money by not replacing all these parts. However , I found that when I went for guidance on trouble shooting that i.e. with the heater that ohmic values of the old part may be near the new part that it may still not be conclusive!? so for a hundred bucks my frig may last 5-10
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
No Ice in the Ice Maker
201 of 237 people
found this instruction helpful.
-
Chris from Duluth, GA
- Really Easy
- Less than 15 mins
-
Socket set
I am NOT a handyman, and my family laughed at me when I said I was going to fix the ice maker all by myself. I ordered a replacement ice maker. When it arrived, I opened the box and read the instructions. It seemed easy. I removed the old ice maker, with a socket set. I then took off the shut off lever from the old one and placed it
... Read more
on the new one, since the new one didn't come with it. I then put the new one in place. All the parts fit perfectly. The ice machine was making ice within an hour. My family was amazed... and I got the last laugh!
Read less
Was this helpful?
Thank you for voting!
Ice Maker stopped working
135 of 154 people
found this instruction helpful.
-
Robert from Port Washington, NY
- Really Easy
- 15 - 30 mins
-
Screw drivers, Socket set
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.
Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)
However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.
... Read more />
Unscrewed the motor assembly (3 screws) with phillips head screw driver.
Screwed in the new unit.
Placed ice maker back into location and tightend the bacing srews.
1 hour later ice was falling!
Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)
However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part.
... Read more />
Unscrewed the motor assembly (3 screws) with phillips head screw driver.
Screwed in the new unit.
Placed ice maker back into location and tightend the bacing srews.
1 hour later ice was falling!
Read less
Was this helpful?
Thank you for voting!
Inlet valve broken from freezing in Storage
109 of 122 people
found this instruction helpful.
-
John from Lincoln, NE
- Really Easy
- Less than 15 mins
-
Nutdriver
Simply remove 5 or 6 self tapping screws to lower the cardboard backing with a 5/16 nut driver. Loosen two screws that hold the valve to the metal lip low on the back. Push 3 easy-connect fittings towards the valve while pulling the poly tube out at the same time. Replace the tubes by simply pushing into the fitting. I did these one a
... Read more
t a time so I wouldn't get them mixed up. Fasten the valve back onto the metal lip, and screw the cardboard back on. Move the Fridge back and the job was all done~!
Read less
Was this helpful?
Thank you for voting!
Fridge was warm. No air circulating at all. Food was spoiling Fridge was just over 1 year old
107 of 122 people
found this instruction helpful.
-
Brian from Smock, PA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
First I removed the two screws that secure the guard in bottom back of the freezer and removed it . Next I removed the two screws that secure the guard on the back wall of the freezer and removed it. There are three wires connected to the motor, I unplugged those and removed the two screws that secure the motor and removed it. I swapped t
... Read more
he grommets, blade and support bracket from the old motor. I put it back together in reverse steps and its working great. My mother-in-law can,t stop thanking me ! I saved her at least $400 to buy a new fridge. Thank You, Brian Miner
Read less
Was this helpful?
Thank you for voting!
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
110 of 140 people
found this instruction helpful.
-
David from Chester, CA
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing
... Read more
the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
Read less
Was this helpful?
Thank you for voting!
icemaker leaking infreezer compartment
103 of 131 people
found this instruction helpful.
-
John from Oberlin, LA
- Really Easy
- Less than 15 mins
-
Nutdriver
first I backed off top two screws and removed bottom screw. unplugged wire harness. removed old icemaker. harness on new icemaker was the same. plugged in hung new icemaker on top two screws installed bottom screw. turned water on job complete and very easy. I was very satisfied with the whole process.
Was this helpful?
Thank you for voting!
Lights inside refrigerator not working
136 of 255 people
found this instruction helpful.
-
Clint from Rayville, MO
- Really Easy
- Less than 15 mins
-
Screw drivers
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
Was this helpful?
Thank you for voting!
Drawers were cracked, trim had fallen off.
84 of 102 people
found this instruction helpful.
-
Julie from Oak Park, MI
- Really Easy
- Less than 15 mins
No need for tools.
Other Parts Used:
Was this helpful?
Thank you for voting!
No water feed to icemaker
81 of 101 people
found this instruction helpful.
-
Robert from Abingdon, MD
- Easy
- 15 - 30 mins
-
Nutdriver, Wrench set
To troubleshoot - Check water supply to valve. It f that's good - remove back plate, remove water valve reconnect inlet line, disconnect electrical connector, place valve over a pan with outlet fitting disconnected, temporarily connect 110 VAC with clipleads to water valve solenoid. No water flow means valve is not opening. To install ne
... Read more
w valve, connect outlet line, and wiring connector, then insert in cabinet and install 2 screws, reinstall back plate, connect water inlet line.
Read less
Was this helpful?
Thank you for voting!
Icemaker made a clicking noise then quit making ice
77 of 96 people
found this instruction helpful.
-
Ryan from Layton, UT
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.
Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that ... Read more covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that ... Read more covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
Read less
Was this helpful?
Thank you for voting!