Ice maker would not work.
6 of 7 people found this instruction helpful.
  • Ed from Glendora, CA
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver
I replaced the dual outlet valve and deiced the filler tube going to the ice maker. I removed the filler tube and ran hot water on it. I believe the old filler valve was leaking letting water slowly into the filler tube where it eventually froze solid.
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people found this instruction helpful.
  • Monica from EDMOND, OK
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people found this instruction helpful.
  • Carl from RIVERSIDE, CA
  • Very Difficult
  • More than 2 hours
  • Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
In the ice storm in bootheel of Mo the power spiked a few times before it went off. When power came back on, my frige wouldn't stay working. I would have to touch the thermostat to make it cycle back on. Found exact parts on line at partselect needed to repair the fridge. thanks guys!
6 of 8 people found this instruction helpful.
  • George from Gideon, MO
  • Easy
  • Less than 15 mins
  • Nutdriver
First I unplugged the appliance, then I took the two screws out that hold the cover over the temp. control knobs,then I removed the cover from the fan and thermocouple probe end. Then I unplugged the two hot wires from the thermostat,and then the ground wire. Then removed the two screws holding the thermostat in place and removed old ther mostat. Installed new thermostat following steps in reverse order.
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people found this instruction helpful.
  • Duncan from Metairie, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
Had to bang on the Thermostat to get the compressor to kick in.
5 of 5 people found this instruction helpful.
  • Richard from O FALLON, MO
  • Really Easy
  • 15 - 30 mins
1.unplugged the refrigerator.and took off 2 knobs, and 2 screws to remove the cover from the back wall of the refrigerator.Next I unhooked 3 wires,and removed the mounting bracket by removing 1 screw. I had to use a file to slightly modify the bracket, since the thermostat was not the exact same model as the original,due to the age of the refrigerator.(40+years) I reassembled in the reverse order, and it works great
Was this helpful?
Thank you for voting!
The door light socket was broken and hanging down
6 of 9 people found this instruction helpful.
  • David from Roanoke, VA
  • Really Easy
  • Less than 15 mins
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this tim e, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Was this helpful?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people found this instruction helpful.
  • Wayne from Arlington, TX
  • A Bit Difficult
  • Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Was this helpful?
Thank you for voting!
Filler tube to the ice maker would freeze up
5 of 6 people found this instruction helpful.
  • Fred from Rockport, TX
  • A Bit Difficult
  • 1- 2 hours
  • Screw drivers, Socket set, Wrench (Adjustable)
Pulled the fridge (KitchenAid side by side) out from the wall for the 1st time in a few years and dealt with those issues. Followed the instructions which were pretty clear. I was lucky enough that I did not need to retro fit any of the connections - it was really a straight forward replacement. The ice maker and the water dispenser have never worked better. Took about an hour.
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!
Refrigerator light would not stay on
4 of 4 people found this instruction helpful.
  • Dave from Manchester Center, VT
  • Easy
  • 15 - 30 mins
  • Nutdriver, Socket set
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Was this helpful?
Thank you for voting!
would shut off and not restart without tapping on knob
4 of 4 people found this instruction helpful.
  • Brad from RAINIER, OR
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
replaced the cold control thermostat . The new one was oriented 90 degrees off (on the bracket mount) so I had to turn it (in the bracket) to line up better with the wire connections and temp sensor tube. The power wires can be connected to either terminal however, and I suppose you could leave it as is if your wires can reach. Turning it will make the knob off 90 deg. off from original markings (off to coldest) but I simply remarked the position with a marker. (make sure you connect all terminals before mounting the bracket, it's much easier that way. .Note: this was a 40+ year old Sears "Coldspot" refridg. and it works like a dream since I changed out this original cold control. Love these old mechanical appliances that are much more reliable than the new brokered ones. Glad whirlpool has made many parts interchangeable through many years...kudos to them
Was this helpful?
Thank you for voting!
Light in my refrigerator didn't work.
5 of 7 people found this instruction helpful.
  • Joseph from Byron Center, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved m e $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.