Condenser fan motor froze up
2 of 4 people
found this instruction helpful.
-
Douglas from Mesa, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people
found this instruction helpful.
-
Richard from North Easton, MA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi
... Read more
er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Read less
Was this helpful?
Thank you for voting!
Ice maker was not working.
1 person
found this instruction helpful.
-
GREGG from WEST CHESTER, PA
- Really Easy
- 30 - 60 mins
-
Nutdriver
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice
... Read more
maker. Gregg in PA.
Read less
Was this helpful?
Thank you for voting!
original motor stopped
2 of 4 people
found this instruction helpful.
-
Paul from Lowell, MI
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Socket set
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this helpful?
Thank you for voting!
cooling fan quit
1 of 2 people
found this instruction helpful.
-
George from Belhaven, NC
- Easy
- 30 - 60 mins
-
Nutdriver
Ordered new fan motor on line took out old motor and replaced with new one
Was this helpful?
Thank you for voting!
fan motor had gone bad
1 of 2 people
found this instruction helpful.
-
william from whitwell, TN
- Easy
- 30 - 60 mins
-
Screw drivers, Socket set, Wrench set
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this helpful?
Thank you for voting!
freezer and food section too warm
1 of 2 people
found this instruction helpful.
-
William from Milford, MA
- Easy
- 30 - 60 mins
-
Socket set
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this helpful?
Thank you for voting!
Condenser Fan Failure
2 of 5 people
found this instruction helpful.
-
Al from Tonka Bay, MN
- Easy
- 30 - 60 mins
-
Socket set
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great
... Read more
!
Read less
Was this helpful?
Thank you for voting!
Poor design leaves fitting vulnerable to damage. Part was broken when pushed to close to the wall.
1 of 2 people
found this instruction helpful.
-
Mike from Camas, WA
- Really Easy
- Less than 15 mins
-
Screw drivers
Simply removed the old and replaced with the new part.
Was this helpful?
Thank you for voting!
Water tubing was accidentally broken from the back of the freezer.
1 of 2 people
found this instruction helpful.
-
Lois from Thomasville, AL
- Really Easy
- Less than 15 mins
-
Screw drivers
Removed the two screws holding the funnel in place...removed the old one and replaced it witht he new tubing...screwed screws back in and the jov was complete. It actually took longer to get it out of the sack than it did to put it together
Was this helpful?
Thank you for voting!
Solenoid stem had seperated from valve seat.
1 of 2 people
found this instruction helpful.
-
Gary from Lewisburg, WV
- Really Easy
- Less than 15 mins
-
Nutdriver, Wrench (Adjustable)
Turn off water, removed two mounting screws, unplugged solenoid, removed incoming water connection and plastic pipe to ice maker. Installed new valve, connected water lines, reconnected plug, remounted with screws. Turned water back on, over rode power to ice maker and checked for leaks. Total time about 5 minutes. Very easy repair.
Was this helpful?
Thank you for voting!
Movers broke the icemaker water fill tube shoving my refrigerator through the front door.
1 of 2 people
found this instruction helpful.
-
Christopher from Valley Village, CA
- Really Easy
- Less than 15 mins
-
Screw drivers
I unscrewed the fill tube screws from the back of the fridge, and pulled the tube out.
Then I put the new tube in, screwed the screws back in and reconnected the waterline.
Then I put the new tube in, screwed the screws back in and reconnected the waterline.
Was this helpful?
Thank you for voting!
Motor noise while running and clicking when shutting off
1 of 2 people
found this instruction helpful.
-
Curtis from Sedona, AZ
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this helpful?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
1 of 2 people
found this instruction helpful.
-
Kevin from COVINGTON, LA
- Really Easy
- Less than 15 mins
-
Nutdriver, Pliers
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this helpful?
Thank you for voting!
light did not work on the refrigerator side
1 of 2 people
found this instruction helpful.
-
David from GROVESPRING, MO
- Easy
- Less than 15 mins
bulbs were not burnt out. received the new switch in a few days. watch the short video, was good to see how it comes out. used a putty knife to release the defective switch, removed wires put them on the new one and posed the new switch back in. Not bad Part cost $11.00 7 dollars shipping so for 17 bucks it works great. nice to see what i
... Read more
s inside the refer!
Read less
Was this helpful?
Thank you for voting!