water was leaking under the frig ,wasnt sure what the problem
4 of 4 people found this instruction helpful.
  • stephen from ROCKLEDGE, PA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
decided to take a chance and replace the ice maker,so far no water leaking.feels nice to know the problem is fixed.thanks for the video on how to replace it, thanks again very easy repair
Was this helpful?
Thank you for voting!
Freezer making loud whining noise-Fridge not cooling well
7 of 13 people found this instruction helpful.
  • Dale from Blaine, MN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was befo re. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this helpful?
Thank you for voting!
would shut off and not restart without tapping on knob
4 of 4 people found this instruction helpful.
  • Brad from RAINIER, OR
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
replaced the cold control thermostat . The new one was oriented 90 degrees off (on the bracket mount) so I had to turn it (in the bracket) to line up better with the wire connections and temp sensor tube. The power wires can be connected to either terminal however, and I suppose you could leave it as is if your wires can reach. Turning it will make the knob off 90 deg. off from original markings (off to coldest) but I simply remarked the position with a marker. (make sure you connect all terminals before mounting the bracket, it's much easier that way. .Note: this was a 40+ year old Sears "Coldspot" refridg. and it works like a dream since I changed out this original cold control. Love these old mechanical appliances that are much more reliable than the new brokered ones. Glad whirlpool has made many parts interchangeable through many years...kudos to them
Was this helpful?
Thank you for voting!
The water in the door dispenser would run for several seconds and then start clunking. This resulted in no more water flow.
5 of 7 people found this instruction helpful.
  • Richard from Novi, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I guessed that the water dispenser solenoid was getting weak.
A quick web search led me to PartSelect's website where it was so easy to pull up my refrigerator model with diagrams. I ordered the valve kit, and in 5 days it was in my hands.

Installation was literally 10 minutes. It took longer than that to vacuum all the du st from under and in back of my refrigerator !
Was this helpful?
Thank you for voting!
Ice maker was leaking
6 of 10 people found this instruction helpful.
  • Thomas from San Diego, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
This is an incredibly easy repair.

1) Remove the three screws holding the old icemaker

2) Disconnect the electrical connection (I used a spoon to get in and undo the connector clip

Do the opposite to install the new icemaker.

Total elapsed time was about 5 minutes.
Was this helpful?
Thank you for voting!
Making a god awful racket.
5 of 7 people found this instruction helpful.
  • Michael from Locust Grove, VA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Ok its the garage "adult " Beverage chiller.

Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this helpful?
Thank you for voting!
Light in my refrigerator didn't work.
5 of 7 people found this instruction helpful.
  • Joseph from Byron Center, MI
  • Really Easy
  • Less than 15 mins
  • Screw drivers
At first I went to a local part supplier and they didn't have it in stock but could order it for me for $55.00 plus $10.00 to ship it. I told them I would have to think about it. I went home and got on the computer and found your web site and was I shocked when I saw the same part listed for $6.98 and $7.00 to ship it. You guys saved m e $50.00. The part arrived in two day and took 5 min. to install. I now have light in my refrigerator. Thank you.
Was this helpful?
Thank you for voting!
frig stopped running and everything ruined
7 of 13 people found this instruction helpful.
  • allen from Dickson, TN
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The frig was already empty....removed the plastic control knobs and loosened the hex head screws to remove the cover . The wires were the same at each contact point, so, it took about 15 minuets to adjust the control knob to match the old one and reinstall the thermostat and place the cover...The other 15 minuets I spent finding my wife t o show her the frig was back to work...Just a walk in the park...
Was this helpful?
Thank you for voting!
Ice maker not working
6 of 11 people found this instruction helpful.
  • Raoul from Thousand Oaks, CA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
take out Ice maker tray, remove three screws holding the ice maker, unplug electrical connector. Replace with new Ice maker,Ice started to fill the tray. ENJOY!!
THANKS.
Was this helpful?
Thank you for voting!
Fan motor stopped working.
5 of 8 people found this instruction helpful.
  • John from Clifton Heights, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Was this helpful?
Thank you for voting!
Filler tube broken and old tube frozen over
4 of 5 people found this instruction helpful.
  • Alan from Chino, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Was this helpful?
Thank you for voting!
Refrigerator light would not turn on.
5 of 8 people found this instruction helpful.
  • Suzanne from STERLING HTS, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom. The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
Was this helpful?
Thank you for voting!
Ice maker did not work
4 of 5 people found this instruction helpful.
  • Judy from Galveston, IN
  • Easy
  • Less than 15 mins
  • Nutdriver
Took the old one out and plug the new one in, simply as 1 2 3. Order the part one morning,it was here the next afternoon, the ice maker was fixed in less than a half hour. we will order from you the next time.
Was this helpful?
Thank you for voting!
Ice Maker didn't produce ice cubes.
4 of 5 people found this instruction helpful.
  • Michael from Long Valley, NJ
  • Easy
  • 30 - 60 mins
  • Nutdriver
It was not complicated but it took more squeezing and reaching into the narrow space than actually removing three screws and unplugging the electrical harness. But that was all that was necessary, to install, three screws held the unit in place and re-connect the electrical harness. It saved me about $100 in labor and the inconvenience of scheduling a service call and waiting for a week or so. The best part was that I ordered the unit on line on Tuesday eveining and it was at my home by Friday afternoon with no extra shipping charges. Great service!.
Was this helpful?
Thank you for voting!
Evaporator Fan in Freezer Making Load Noise
4 of 5 people found this instruction helpful.
  • Ralph from SAINT PAUL, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
Was this helpful?
Thank you for voting!