1067627413 Kenmore Refrigerator - Instructions

All Instructions for the 1067627413
31 - 45 of 179

Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!

Search filter:
Clear Filter
Your search term must have 3 or more characters.
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
water leaked when the paddel was pushed
6 of 8 people found this instruction helpful.
  • Monica from EDMOND, OK
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Was this helpful?
Thank you for voting!
Ice maker slowed down, then stopped producing
5 of 5 people found this instruction helpful.
  • Paul from Sharpsburg, GA
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench set
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing wit h two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Was this helpful?
Thank you for voting!
Ice Maker Quit Making Ice
5 of 6 people found this instruction helpful.
  • WILLIAM from Altamonte Springs, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Screw drivers, Wrench (Adjustable)
Ice make was still working but no water coming in to make ice . Pulled refrigerator back and found water valve at bottom of refrig close to the floor. I disconnected water line and electric plug - went to whirlpool web site - no help at all to confusing - found partselect and compaired picture of old valve with picture of new valve . When I got it in mail it took 30 min to install - working fine now hint - mark top of electric plug so you install correctly
Was this helpful?
Thank you for voting!
refrigerator not cooling properly
6 of 9 people found this instruction helpful.
  • Ernie from Windsor, CA
  • Really Easy
  • 1- 2 hours
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Was this helpful?
Thank you for voting!
wasn't making ice. The ice bin actually filled up with water.
5 of 6 people found this instruction helpful.
  • Bob from Middlefield, CT
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the r efrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Was this helpful?
Thank you for voting!
Making a god awful racket.
5 of 7 people found this instruction helpful.
  • Michael from Locust Grove, VA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Ok its the garage "adult " Beverage chiller.

Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Was this helpful?
Thank you for voting!
My U-line ice maker quit filling.
5 of 7 people found this instruction helpful.
  • Anne from Arlington, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bra cket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Was this helpful?
Thank you for voting!
Freezer making loud whining noise-Fridge not cooling well
7 of 13 people found this instruction helpful.
  • Dale from Blaine, MN
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Removed the 3 screws in the back of the freezer, pulled back the metal back plate on the freezer. Removed 4 nuts on the plastic housing that holds the fan and pulled the housing down. Disconnected the wires, unscrewed the 2 screws holding the fan to the housing. Replaced old fan motor with new fan motor onto housing just as it was befo re. Reconnected the wires. And tested the motor. Worked great. Re-assembled everything as it was and it was done.
Was this helpful?
Thank you for voting!
Fan motor stopped working.
5 of 8 people found this instruction helpful.
  • John from Clifton Heights, PA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Was this helpful?
Thank you for voting!
Broken filler tube at threaded connection
4 of 5 people found this instruction helpful.
  • Matthew from Phoenix, AZ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Was this helpful?
Thank you for voting!
nosiy fan operation
4 of 5 people found this instruction helpful.
  • TOM from GRANVILLE, MA
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Was this helpful?
Thank you for voting!
Filler tube broken and old tube frozen over
4 of 5 people found this instruction helpful.
  • Alan from Chino, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Was this helpful?
Thank you for voting!
Evaporator Fan in Freezer Making Load Noise
4 of 5 people found this instruction helpful.
  • Ralph from SAINT PAUL, MO
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Removed freezer shelving. Removed 3 shelving brackets (dovetailed) by sliding them up off of the small square mounted on the freezer wall. This was a stumbling block until
I figured out how to remove these brackets. Removed three Philips head screw in freezer back panel (24) with nut driver. Removed light bulb cover to get some grip on back panel. Lifted the back panel up slightly and then folded in down a bit then rotated it to the left. Removed 4 hex head (1/4in) screws on fan shroud (23) and brought down into the freezer. Disconnected electrical spade connectors from motor and removed entire unit from freezer to work on motor. Removed two hex head screws (18) holding motor to the brackets. Pushed new fan on to new motor using a 1/4 nut driver and hammer. Mounted motor to old brackets with two screws (18). Placed motor/fan/shroud unit in freezer and reconnected electrical spade connectors. Replaced motor/fan/shroud in freezer with the 4 hex head screws (15), dropping one behind the coils. Just replaced it with a look alike. Turned power back on to check if the fan was operating normally. Put back panel in place and screwed it in place then put shelving clips back into place and then all the shelving. Appears to operating quietly so far. About 30 minutes to complete the job.
Was this helpful?
Thank you for voting!
Fan motor
3 of 3 people found this instruction helpful.
  • Bonnie from DETROIT LAKES, MN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Remove bottom of freezer by sliding out the gaskets on each side.

Remove back of freezer. 6 screws.

Remove fan cover. 4 screws.

Remove fan. 3 wires to disconnect. 2 screws to take out.

Install the fan. Connect the 3 wires. Fastened with 2 screws.
Put fan cover back on. 4 screws. ... Read more >Put back of freezer back on. 6 screws.
Put bottom of freezer back in. Slide gaskets in on each side.
Was this helpful?
Thank you for voting!
All Instructions for the 1067627413
31 - 45 of 179