Freezer Cold - Refrigerator Warm
3 of 7 people found this instruction helpful.
  • William from Fairfield Glade, TN
  • Easy
  • Less than 15 mins
  • Screw drivers
After searching online to diagnose the issue with my refrigerator being warm and the freezer being cold and not shutting off to defrost I decided to get the defrost timer kit. The kit arrived within 2 day. With the directions included, after unplugging the appliance for safety, I installed it relatively quickly with only a screwdriver . I then plugged it back in and it immediately went to defrost. I thought, wow I have it fixed. Well unbeknownst to me it still didn't cool in the fridge area. After doing more internet research I found a suggestion to unplug the fridge for 24 hours to unthaw ice that may be lodged between the freezer and fridge that is blocking the distribution of cold air into the fridge. After doing this, it now works like a charm.
Was this helpful?
Thank you for voting!
fridge making bad noise
2 of 4 people found this instruction helpful.
  • Kevin from LEVAN, UT
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
Removed cover change mounting bracket on fan put it back in works great
Was this helpful?
Thank you for voting!
Condenser fan motor froze up
2 of 4 people found this instruction helpful.
  • Douglas from Mesa, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
Was this helpful?
Thank you for voting!
Condenser fan making noise
2 of 4 people found this instruction helpful.
  • Richard from North Easton, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Wrench set
I removed 7 screws hold the heavy cardboard cover on the rear of the fridge. The dificult part was taking the screws that hold the 3 fan motor braces on the fan out. After that it was a matter of making the wire conections and putting it back in. I did not have enough room to laydown to do the work, If i had it would have been a lot easi er to see the screws that had to be removed. All in all an easy job, and the part was a perfect fit.
Was this helpful?
Thank you for voting!
Freezer made lots of Ice and Refrigerator didn't cool
4 of 10 people found this instruction helpful.
  • Cecelia from Garden City, TX
  • Really Easy
  • 30 - 60 mins
  • Screw drivers
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator bran d new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.
Was this helpful?
Thank you for voting!
original motor stopped
2 of 4 people found this instruction helpful.
  • Paul from Lowell, MI
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Socket set
removed old and instaslled new. biggest problem was getting to one of the screws.
Was this helpful?
Thank you for voting!
fan motor had gone bad
1 of 2 people found this instruction helpful.
  • william from whitwell, TN
  • Easy
  • 30 - 60 mins
  • Screw drivers, Socket set, Wrench set
I removed the nuts that held the motor mount, then removed fan blade, cut the wires, and slid the motor pass the mounts and the coil shroud, Installed motor in reverse order. worked out ok.
Was this helpful?
Thank you for voting!
freezer and food section too warm
1 of 2 people found this instruction helpful.
  • William from Milford, MA
  • Easy
  • 30 - 60 mins
  • Socket set
removed lower back cover. diconnected fan ass'y electrical connection, removed fan housing (3 screws). removed fan motor from housing. cut old connector from fan and installed on new fan with wire nuts included. re-installed new fan to housing and re-installed housing to frame.
Was this helpful?
Thank you for voting!
Condenser Fan Failure
2 of 5 people found this instruction helpful.
  • Al from Tonka Bay, MN
  • Easy
  • 30 - 60 mins
  • Socket set
Partition between Freezer and Fridge was running very hot. (Warm is normal). Oiling fan did not work. The only problems encountered in the replacement were getting fan out and in through coolant lines, cut plug off to accomodate generic fan wiring, getting the screws back in without cooking your hand on a hot compressor. Unit works great !
Was this helpful?
Thank you for voting!
Refrigerator compartment warm
1 of 2 people found this instruction helpful.
  • alfonso from Fairfield, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
first confirm that freezer is cold. if is frozen solid it needs to be defrosted. take the freezer items out,take shelf out, bottom cover, 2 screws. then ice maker, 3 screws and unplug wires. then back panel 2 screws. In refrigerator compartment were the controllers are located, look under it you will see 1 hole, insert a flat end screw dr iver and turn clockwise till it stops. this action will turn on your defroster, also the compressor will stop. is the heater melting the ice? if so soak up water and clean tray, use hair dryer in drain hole to aid in the defrost, check tray under fridge and if its dry keep defrosting. it should take half an hour. now take the flat head screw driver and turn the defrost timer clock wise out of defrost mode a quarter turn or so. the compressor should come back on, soon after the fan in the freezer compartment should also come on. this steps lets you no that the defrost heater works, fan works and drain hole is clear. if its defrosted place parts back in the reverse order. if not defrosted replace heater or mother board. in refrigerator compartment were the dials are located their are 2 screws, one on the left and the other on the right side take them out, the cover will drop down, you will find wiring schematics you will need them to install defrost timer. is timer making ticking sound? if no replace timer. new timer will be different from original so follow instructions that come with it. timer is above were the hole is located. the plastic hold downs will break when you try to take them off, unplug fridge, lift timer out and remove from wire harness. the new timer has a black wire that slips over either 1 or 2 depending on color of wire on the wire harness. check schematics. some silicone adhesive will keep unit in place, ad some into the plastic shaft prior to installation, plug wire harness return wiring instruction along with new one inside of cover, plug in fridge, turn defrost timer clock wise with flat head screw driver making sure that you hold timer from above so it wont move. did compressor come on?. put all paper work inside of cover before installing cover
Was this helpful?
Thank you for voting!
cooling fan quit
1 of 2 people found this instruction helpful.
  • George from Belhaven, NC
  • Easy
  • 30 - 60 mins
  • Nutdriver
Ordered new fan motor on line took out old motor and replaced with new one
Was this helpful?
Thank you for voting!
Motor noise while running and clicking when shutting off
1 of 2 people found this instruction helpful.
  • Curtis from Sedona, AZ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
The instruction sheet supplied with the new motor described the steps to take very good. Replaced the rubber grommets for the three motor mounts also. A flashlight or light source was needed or was very helpful.
Was this helpful?
Thank you for voting!
The freezer worked but the refrigerator wouldn't cool.
1 of 2 people found this instruction helpful.
  • ROBERT from KIRKWOOD, MO
  • Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
When we got the part, we read the instructions, which were easy and very clear step by step. Taking the old part off took most of the time, it was attached a little differently than was described in the video and the instructions for the part. Once we detached that, the replacement part went in very easily and quickly. It took a short w hile for the cycle to start, we were actually a little worried that it wasn't going to work. Then it started cycling. After the first day the freezer had started icing up, we took a blow dryer and melted it and waited. It hasn't started freezing up again. The refrigerator is keeping the proper temperature and the freezer is also working properly, it's been a week. We seem to be obsessed with going out and checking to see if it's working but I think it's a success. Doing this ourselves only cost $26.00. A huge savings if we had hired someone else to repair it for us. We will definitely choose this option with any other appliance that needs repair. It was easy and simple to find the correct part thanks to the website. And the video tutorial was very informative and helpful.
Was this helpful?
Thank you for voting!
refrigerator stopped cooling due to condenser over-heating
1 of 2 people found this instruction helpful.
  • Kevin from COVINGTON, LA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers
Pull refrigerator out to access back, unplug unit and remove the 3 .25" screws cut the power leads to motor and install new with easy to understand instructions provided with new motor. Plug refrigerator back in and enjoy your cold beverages once more. EASIEST REPAIR EVER.
Was this helpful?
Thank you for voting!
Refrigerator would not stay cold
2 of 6 people found this instruction helpful.
  • Jeremy from State College, PA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Wrench set
Removed rear cover to see non-operating fan - removed three mounting screws on the motor that were a challenge to access. Swapped fan from old motor onto new motor - one threaded nut on the motor shaft. Spliced new fan wires into fan wires of the wiring harness and mounted with three self-tapping screws supplied with new fan motor. Repl aced rear cover and plugged it in! Now the refrigerator cools like new (1981 model side-by-side Admiral)
Was this helpful?
Thank you for voting!
All Instructions for the 1067382
46 - 60 of 129