frosted evaperator
  • Burton from Mount ShaSTA, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
I was a Sears repair man for fourty eight years , so I don"t think I should say how easy this was.
Was this helpful?
Thank you for voting!
Loud noise from freezer when running
  • Joseph from Cottsge Grove, WI
  • Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
Pulled the electric plug! Removed the freezer shelf and the rear shelf supports by pulling straight up. Swung rear panel out of the way after taking out the two phillips head screws at the top. Removed the plastic deflector grill to which the motor is attached with a nut driver. Removed motor from grill and disconnected wire prongs (pul l off). Attach new motor. Only issue - the ground prong has been moved to the front of the motor so the wire just reaches and has to be gently bent back so the fan blade clears it. Reattach deflector grill. Push on fan blade, but not too far to hit wire. Reassemble the rest in reverse order.
Was this helpful?
Thank you for voting!
No Light
  • Mary from Jefferson Township, PA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
Took socket out and replace it with new one. Very easy. W saved alot of money doing it ourself.
Was this helpful?
Thank you for voting!
The Refrigerator Was Running But Blowing Hot Air, Everything In Freezer Had Defrosted.
  • Jeanne from Fairview Heights, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
First I watched the video on your website, it was quite helpful. It showed me the location of the part to be replaced. Then I used the nut driver to remove a couple of screws, and slowly pulled the cover off . Once I pulled the cover down I could see the part that needed replacing, it had a couple of phillips head screws holding it in place, I removed those screws and unplugged the defrost timer, taking note of the color of the wires. Then I took the new defrost timer and attached the loose wire to the correct terminal according to the directions(this is where the color of your wires comes in), then I plugged in the new defrost timer and replaced the screws. I then reattached the cover making sure not to pinch any of the wires, and replaced the screws. It was so easy I was sure I did something wrong and it wouldn't work, but I plugged the refrigerator back in and let it sit for about 20 minutes and then when I checked it was running cool. I'm 55 years old and never had the nerve to try anything like this before but since my husband passed away I've had to try things myself or replace a lot of appliances. If I can do it anyone can.
Was this helpful?
Thank you for voting!
Water was running into refrig from freezer and ice cream was soft
  • William from Delano, MN
  • Really Easy
  • Less than 15 mins
  • Nutdriver
We wasted time looking for the electrical schematic on our refrigerator (the first step in the instructions). By skipping that and reading further in the instructions, the type of cooling that the refrigerator has can easily be determined by the colors of the wires that go to the defrost timer. You need to know this to set up the timer properly for your specific refrigerator. Had I just started there, the entire repair would have taken less than 10 minutes. Very simple repair and it works like a charm, no more water coming into the refrigerator and the ice cream is rock hard. Glad we didn't have to spend lots on a new appliance. Thanks Part Select.com! BH
Was this helpful?
Thank you for voting!
Evaporator Would Freeze Up And The Food Section Could'nt Cool
  • michael from buchanan, TN
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I just followed the enclosed instructions
Was this helpful?
Thank you for voting!
fan motor did not run all the time
  • Charles from Marion, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
unpluged refrigerator. removed panel in front of fan. Removed the fan motor. Installed the new fan kit. Replaced the panel in front of fan. Pluged the refrigerator back in. The refrigerator runs a 100 percent better
Was this helpful?
Thank you for voting!
evaporator fan, noisy
  • John from Iselin, NJ
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Remove freezer shelves, panel, and change fan.
Was this helpful?
Thank you for voting!
Light bulb failure
  • Grant from Alexandria, VA
  • Really Easy
  • Less than 15 mins
Received the part the day after ordering. Appreciated the quick service and repair took less than a minute.
Was this helpful?
Thank you for voting!
Protective cover for bulb had melted
  • Lee from Brooklyn, NY
  • Very Difficult
  • 15 - 30 mins
  • Screw drivers, Wrench (Adjustable)
I tried to just replace the cover rather than the whole unit but it was impossible - the cover would not go/stay on. I tried to remove the old unit completely but it would not unplug it was practically fused to the back of the fridge and the liner was cracking. I ended up breaking the cover and jerry rigging it over the bulb to prevent i tems in the fridge from being able to touch. Bad solution.
Was this helpful?
Thank you for voting!
How to get timer out of defrost cycle?
  • David from Virginia Beach, VA
  • A Bit Difficult
  • 15 - 30 mins
  • Socket set
Talked to local appliance repair tech, who explained how to manually turn timer with a screw driver and listen to the switch go from on to off.
Was this helpful?
Thank you for voting!
Evap Fan Motor went bad
  • Aaron from Metz, WV
  • A Bit Difficult
  • 30 - 60 mins
  • Pliers, Screw drivers, Socket set
This was an easy part to find thanks to its universality. The only difficulty was the electric snap-on connection - had to use the old one and tie the wires to the new motor - that was easy. Hardest part was the new screws to mount to bracket weren't long enough. Had to find one in my screw jar to match threads that was long enough. W orks Great!!!
Was this helpful?
Thank you for voting!
Freezer was not Defrosting
  • Andrew from Pinckney, MI
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
I have an Amana freeze and I followed the procedure in the video. Which is very good! However on the Amana Model there two slight differences in the procedure that I felt I needed to do. The first one is, the condenser fan bracket is attached to the Freezer chassis with 4 screws, not three. The removal and installation of the back screw b y the fan is a bear. I removed the other three and it allowed me to rotate the fan slightly to get more access to the fourth and did same on installation by just starting the 4th screw and then tightening it later. The second issue was my new fan hit the housing when I spun the fan. When I looked at the old one. It had a phenolic washer, between the fan and motor which spaces the fan out about a washer thickness from the motor. When I tried to remove the old one it broke in four pieces due to age. So, I made my own with a washer that I super glued to the motor housing after carefully centering it on and clearing the motor shaft . Seemed to work with out any more noise or balance issues...Thanks, your delivery was blindly fast and video was great!
Was this helpful?
Thank you for voting!
Evaporator motor squeal.
  • Steven from Hilliard, OH
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
After finding an almost obsolete part( thanks PartSelect!) the installation was rather easy. Remove the back panel of the freezer and vent with a screwdriver and a nut driver. Disconnect the three wires, green, white and red.Remove motor from mounting and replace with new motor. I had to make a slight adjustment to the ground wire on the new motor that required adjusting the position of the contact-no big deal. The motor fit perfectly. Popped fan on and assembled. 20 minutes max.
Was this helpful?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
  • John from LAS CRUCES, NM
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Was this helpful?
Thank you for voting!
All Instructions for the 106726