The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people found this instruction helpful.
  • Jorge from Miami, FL
  • Easy
  • 15 - 30 mins
  • Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Was this helpful?
Thank you for voting!
Ice getting stuck, and water flowing over everything
7 of 7 people found this instruction helpful.
  • Randal from Wakefield, RI
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The on-line video and the hard-copy instructions with the replacement part made it very easy. Just loosened the 2 upper screws and took out the bottom one. Eased the ice maker out a bit and disconnected the plug at the back (power was off). Checked the replacement part had exactly the same wiring harness - it did. Fitted the bail arm from the old one. So simply did the same process in reverse. So 15-20 minutes after I started, the job was compelete. It takes a while for ice to start coming, but it did, and after 24 hours I threw out the ice and started again to make sure the ice came from fresh water.
Was this helpful?
Thank you for voting!
Ice maker leaked into ice reservoir
7 of 7 people found this instruction helpful.
  • joe from hilliard, OH
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
The ice mold has a coating on it. Over time the coating deteriorates. If your ice maker leaks water into the ice reservoir inspect the mold to see if the coating is compromised. If so, replace with new.

Remove the ice maker assembly. 3 small hex screws. Unplug power cord. Disassemble ice maker assembly. Remove ice mold/h eater. Replace with new. Reassemble.
Was this helpful?
Thank you for voting!
The Freezer was cold but the refrigerator was warm. The Fan motor had gone out.
7 of 7 people found this instruction helpful.
  • Thomas from GATESVILLE, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver
It was very easy and I'm not a handyman by any stretch of the imagination. I just removed the back inside panel of the freezer. The I unscrewed the fan mounting bracket. Unclipped the wires. Removed the old fan blade and put it on the new motor. I then attached the wires to the new motor and secured it with the old mounting brackets. I then replaced the back panel. The fridge is working like new now.
Was this helpful?
Thank you for voting!
Freezer No Longer Cools
7 of 8 people found this instruction helpful.
  • STEPHEN from FENTON, MO
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.

I emptied the refrigerator completely, removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.

I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.

After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.

** Side Notes **

Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.

** For the PartSelect Website Maintainers **

If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Was this helpful?
Thank you for voting!
broken end cap
10 of 17 people found this instruction helpful.
  • Stefanie from Sycamore, IL
  • Really Easy
  • Less than 15 mins
Simple....snapped it right on...the important thing is that we ordered it for a reasonable price, and it arrived quickly...within 3 days. thanks!!!
Was this helpful?
Thank you for voting!
light not working in fridge
7 of 8 people found this instruction helpful.
  • Michael from East Meadow, NY
  • Really Easy
  • Less than 15 mins
  • Screw drivers
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Was this helpful?
Thank you for voting!
Black flecks in ice
6 of 6 people found this instruction helpful.
  • Anthony from Billings, MT
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
The lining of the ice mold (Whirlpool) started flecking off (black flecks in the ice cubes), so I decided to replace the mold.
Loosen the two 1/4 inch upper nuts and remove the lower nut to remove the ice maker from the freezer. The hardest part was getting it unplugged. I used a small blade screwdriver to release the catch on the c onnector and pull it out.
Remove the ice maker front cover. If you have a skinny enough phillips screw driver, there are two deep set screws through two holes on the lower portion of the control module (otherwise, remove the three screws on the controller, unlatch the shut-off arm from the control module, and separate the controller to access the mold screws). Unhook the shut-off wire from the end of the tray. Unscrew the two screws holding the mold and remove the mold.
Remove the plastic hardware from the old mold and install on the new mold.
Attach the new mold on to the control module.
WARNING WARNING WARNING!!! The mold I bought already had the alumilastic on it for the contact point to the thermostat. When I installed it and tightened the screws, the alumilastic was dried out, didn't squash down, and dented the bi-metal thermostat on the controller, ruining it. I had to buy a new thermostat. Be sure to check that the alumilastic is pliable. If not, take it off and buy some fresh to put on there.
Re-install the ice maker. It took a while to get the first batch of ice because the ice maker was at room temperature and I had the freezer door open for several minutes. So the freezer had to get cold and the ice maker had to chill down. Once everything got cold, it started making ice again.
Was this helpful?
Thank you for voting!
No ice was being made
11 of 21 people found this instruction helpful.
  • Reinhold from Cheshire, CT
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Wrench (Adjustable)
I looked up the refrigerator on the internet and found this website. I got the diagram of the parts of the icemaker and found that the valve must be defective because no water was coming up to the icemaker.
I ordered the part which came the next day. Took out the screws, conected the water line to the new part. moved the electrical connection to the new part and we had ice. Saved a lot of money that the plumber would have cost.
Was this helpful?
Thank you for voting!
fan made lots of noise
7 of 9 people found this instruction helpful.
  • jim from bedford, KY
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
unplugged refrig.
removed screws on back panel of freezer compartment

removed fan motor cover

removed fan

broke ends off support bracket in accordance with directions

had to pull more of old ground wire out of back of refrigerator to get it to reach ground clip on new fan

plugge d all 3 wires into fan motor

replaced covers

every thing works fine now.

part was delivered quite promptly

refrigerator was over 30 years old and a sears model but mfg by whirlpool
Was this helpful?
Thank you for voting!
fan not working
7 of 9 people found this instruction helpful.
  • Gary from Erving, MA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
unpluged unit, removed 2 panel screws, removed 4 fan screws, disconnected wires, reassembled
Was this helpful?
Thank you for voting!
no power to the ice maker
11 of 21 people found this instruction helpful.
  • Thomas from Indianapolis, IN
  • Really Easy
  • Less than 15 mins
  • Nutdriver
The wiring harness was a straightfoward plug in replacement after depressing the securing tabs, and did provide power to the icemaker. However, the icemaker would continually cycle, with the mold heater on at all times. I suspect this is what caused the thermal fuse to blow in the first place. Rather than spend more time replacing individ ual components, I eneded up replacing the full ice maker assy. The new ice maker works properly.
Was this helpful?
Thank you for voting!
old valve was not shutting off fully, flooding ice-maker, creating a glacier
6 of 6 people found this instruction helpful.
  • duncan from HOWELL, NJ
  • Very Easy
  • Less than 15 mins
  • Nutdriver, Wrench (Adjustable)
Shut off water supply, removed old valve (two screws, 1/4' nut driver), disconnect electrical plug, remove water lines (adjustable wrench). Cut fitting off tube to ice-maker (new unit has a push-to-connect fitting). Replace water lines and electrical connector. Mount valve back on cabinet. Turn water back on.
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people found this instruction helpful.
  • David from Choctaw, OK
  • Easy
  • 30 - 60 mins
  • Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people found this instruction helpful.
  • Peter from Herndon, VA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!