power surge killed the fan motor
27 of 35 people found this instruction helpful.
  • Joe from Arnold, MD
  • Easy
  • 1- 2 hours
  • Nutdriver, Pliers
Removed back panel in the freezer. Removed old fan. Installed new fan and reinstalled back panel.
Was this helpful?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
27 of 36 people found this instruction helpful.
  • Florentino from Windsor Locks, CT
  • Easy
  • 30 - 60 mins
  • Nutdriver
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Was this helpful?
Thank you for voting!
plastic gear broke off - cubes not getting kicked out
23 of 25 people found this instruction helpful.
  • Laurence from Middleton, WI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
removed the three screw holding the broken unit - pulled off the old module.

Before I could install new module I had to loosen some fasteners on ice maker so I could turn shaft to align with new module.

Then push on new unit and three screws. Had tumbling ice in about an hour. My wife thinks I'm a hero. (I am)
Was this helpful?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
22 of 23 people found this instruction helpful.
  • W from Nellysford, VA
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also uns crewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Was this helpful?
Thank you for voting!
Ice Magic Plus stopped making ice
25 of 35 people found this instruction helpful.
  • George from Hammond, LA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First I removed the icemaker from the freezer by removing two horizontal screws holding it to the side wall, and one vertical screw holding the front to a bracket coming off the side wall. Then I used a flat screwdriver to unlock the electrical plug. (After doing this, I realized that this wasn't necessary at all, and this part could have been changed just as easily without removing the icemaker.) On the front, there is a white cover with Ice Maker Plus. Use a flat screwdriver to unlock the tangs and remove the cover. There are three screws in the corners that once removed, will allow the motor assy. to be gently pulled straight out. On the back of the part, you will see many gold lands that the timer touches. I don't think there was anything wrong with my motor. I had two spots where the gold plating was worn off, so I suspect it was not making contact, and the whole process would stop. Slide the new part in place making sure the teeth on the gears line up (not a big deal), and secure with the screws. Install cover and you're done. Mine has been making ice like it was brand new.
Was this helpful?
Thank you for voting!
The old motor wouldn't turn the fan.
24 of 32 people found this instruction helpful.
  • Bob from Hesston, KS
  • Easy
  • 15 - 30 mins
  • Socket set, Wrench set
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Remova l of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Was this helpful?
Thank you for voting!
Refrigeator would not drfrost...
27 of 44 people found this instruction helpful.
  • Curtis from Pikeville, KY
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Socket set, Wrench set
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.

Thank you
Curtis Hall
Was this helpful?
Thank you for voting!
ice would not fall from ice maker
22 of 30 people found this instruction helpful.
  • Greg from Cary, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
Was this helpful?
Thank you for voting!
Water was overflowing into ice bin.
22 of 31 people found this instruction helpful.
  • Russell E from Rome, PA
  • Really Easy
  • 1- 2 hours
  • Nutdriver, Pliers
First I ascertained that valve was faulty. Ordered replacement and installed without issue. Water now overflowed only during fill and found that filler neck had ice in it as a result of initial leakage. Defrosted with a hair dryer, removed ice plug and it now works as advertised.
Was this helpful?
Thank you for voting!
Ice maker would not fill with water
20 of 25 people found this instruction helpful.
  • William from Springville, AL
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Wrench (Adjustable)
Turn off the water supply.
Remove the two screws with a nut driver.
Disconnect the electrical connector.
Disconnect the water supply lines from the old valve.
Reconnect the water supply lines to the new valve.
(be sure to push the water line into the quick connect securely)
Reconnect the electrical connector .
Re-install the valve with the two screws.
Turn water supply on.
Was this helpful?
Thank you for voting!
Over flowing Icemaker
21 of 29 people found this instruction helpful.
  • Thomas from Flower Mound, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray.
After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later.
Over flowed and iceberg would form at rear.
Replaced icemaker unit and works fine now.
Was this helpful?
Thank you for voting!
We broke the rail. :(
17 of 19 people found this instruction helpful.
  • heather from union bridge, MD
  • Really Easy
  • Less than 15 mins
We decided to use our crisper drawers to store sodas. Duh..bad plan. The rail that holds the drawers up cracked in half. So we just had the drawers sitting on the bottom of the fridge. So, I got the new rail THE DAY AFTER I ORDER IT! I just recycled the old one, and slid the new one in. Presto. Perfect fit. Actually, better then perfect. There must have been a defect with my old one, because the new one actually SNAPPED into place, instead if just sitting in the frame. So..I am really pleased.
Was this helpful?
Thank you for voting!
compressor didnt turn on
24 of 41 people found this instruction helpful.
  • gerardo from el monte, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
changed the starter connected to the compressor
Was this helpful?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
21 of 32 people found this instruction helpful.
  • jesse from hacienda heights, CA
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Pliers, Screw drivers
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Was this helpful?
Thank you for voting!
Refrigerator No Longer Cooling Properly
15 of 15 people found this instruction helpful.
  • Elizabeth from DELRAY BEACH, FL
  • A Bit Difficult
  • More than 2 hours
  • Nutdriver, Screw drivers
Approximately:

1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi -mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.

This worked! Yahoo.

p.s. I am a 65+ year old mechanically minded woman. :-)