10666765 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Refrigerator quit refrigerating
15 of 21 people
found this instruction helpful.
-
William from Hudson, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit ... Read more is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
Read less
Was this helpful?
Thank you for voting!
I had frost build-up in the freezer.
15 of 21 people
found this instruction helpful.
-
David from Arnold, ME
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
Was this helpful?
Thank you for voting!
Noise coming from defrost timer
12 of 14 people
found this instruction helpful.
-
Thomas from Pottstown, PA
- Really Easy
- 15 - 30 mins
-
Nutdriver
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in
... Read more
the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
Read less
Was this helpful?
Thank you for voting!
would not cycle
12 of 16 people
found this instruction helpful.
-
Maxine from Birmingham, AL
- Really Easy
- 15 - 30 mins
-
Nutdriver
removed the defrost timer and replaced with new unit now i have a refrigerator again
Was this helpful?
Thank you for voting!
condenser fan stopped working
10 of 12 people
found this instruction helpful.
-
Steven from Brigham City, UT
- Really Easy
- 15 - 30 mins
-
Nutdriver
1. Removed the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
2. Removed the terminal block and unplugged the old motor.
3. Removed three screws that held old motor to the bracket.
4. Removed the fan blade from the old motor.
5. Installed the fan blade (after cleaning) to the new motor.
6. Crimped on new wire terminals onto the leads on ... Read more the new motor.
7. Installed the new motor using the fasteners provided.
8. Plugged the new motor wires onto the proper terminals in the terminal block.
9. remounted the terminal block.
10. reinstalled the cardboard cover.
Read less
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
Condenser fan motor seized
9 of 9 people
found this instruction helpful.
-
Benjamin from Daytona Beach, FL
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Tot ... Read more al time of ice maker water leak repair and fan replacement about 1 hour.
Read less
Was this helpful?
Thank you for voting!
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
10 of 13 people
found this instruction helpful.
-
JAMES from Middleboro, MA
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
Unplug
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Remove entire back panel (both chipboard and metal fan grill)
Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in
When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip hold ... Read more ing the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black)
Unplug both fan wire connects from circuit block to release the fan power cable.
Remove the fan mounting plate
Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades
Unscrew motor from brackets - note alignment of motor on brackets
Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire)
Connect new plug wire to the circuit block keeping wires connected to the proper terminals
Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser
Plug wire harness into motor and re-mount fan mount plate
Reattach fan blade and secure using blade mount kit
Replace back panels
Read less
Was this helpful?
Thank you for voting!
No water in icemaker tray.
9 of 10 people
found this instruction helpful.
-
Robert from Myrtle Beach, SC
- Really Easy
- 15 - 30 mins
-
Nutdriver
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no wate
... Read more
r was getting through. Replacing the valve was a snap.
Read less
Was this helpful?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
9 of 11 people
found this instruction helpful.
-
paul from madison, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker ha
... Read more
s been working flawlessly since the repair.
Read less
Was this helpful?
Thank you for voting!
fan had stopped-freezer not performing etc.
8 of 8 people
found this instruction helpful.
-
George from Glenwood, MN
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws
... Read more
and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Read less
Was this helpful?
Thank you for voting!
water pump for ice maker would not shut off
7 of 8 people
found this instruction helpful.
-
Lawrence from Clio, MI
- Really Easy
- Less than 15 mins
-
Screw drivers, Wrench (Adjustable)
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Was this helpful?
Thank you for voting!
freezer will not freeze or cool the ice box
8 of 13 people
found this instruction helpful.
-
David from Choctaw, OK
- Easy
- 30 - 60 mins
-
Socket set
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not workin
... Read more
g correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Read less
Was this helpful?
Thank you for voting!
Condenser Fan Motor seized up
6 of 7 people
found this instruction helpful.
-
Peter from Herndon, VA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!
Service and shipping were fantastic! I would definitely use Partselect again!
Service and shipping were fantastic! I would definitely use Partselect again!
Was this helpful?
Thank you for voting!
Ice maker slowed down, then stopped producing
5 of 5 people
found this instruction helpful.
-
Paul from Sharpsburg, GA
- A Bit Difficult
- 30 - 60 mins
-
Socket set, Wrench set
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing wit
... Read more
h two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Read less
Was this helpful?
Thank you for voting!