socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!
Freezer not coolling properly. Lower temp. 2 degrees upper temp. 60 degrees.
10 of 12 people
found this instruction helpful.
-
John from Blairsville, GA
- Really Easy
- 15 - 30 mins
-
Nutdriver
Take bottom racks and baskets out of freezer. Remove back sheet metal panel, 8 screws. Remove motor and bracket, 2 screws. Umplug wires on motor. Remove two more screws to take mounting bracket off motor. Install in reverse order. Simple job. Maybe 20 minutes. Besure to shut freezer off before startin work.
Was this helpful?
Thank you for voting!
Blower motor expired
10 of 12 people
found this instruction helpful.
-
Raymond from Cedar Falls, IA
- Really Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Pulled off the interior panel, removed the old blower, reinstalled the new one, plugged the frig in to make sure it ran and replaced the interior panel.
Was this helpful?
Thank you for voting!
No water in icemaker tray.
9 of 10 people
found this instruction helpful.
-
Robert from Myrtle Beach, SC
- Really Easy
- 15 - 30 mins
-
Nutdriver
Confirmed that the solenoid controlled water valve (Part # PS358631) between the water source and the back of ice maker was defective. I did this by removing the valve and plastic hose from the back of the refrigerator and pointed the end that went into the icemaker towards the sink. I applied 110 volts to the valve and noted that no wate
... Read more
r was getting through. Replacing the valve was a snap.
Read less
Was this helpful?
Thank you for voting!
There was no light on in refrig area
12 of 19 people
found this instruction helpful.
-
Lori from Chuluota, FL
- Easy
- Less than 15 mins
-
Screw drivers
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Was this helpful?
Thank you for voting!
The refrigerator leaked water every time the ice maker filled.
11 of 16 people
found this instruction helpful.
-
Robert E. from Darien, IL
- A Bit Difficult
- Less than 15 mins
The problem was discovered to be a cracked fill tube head, This part extends behind the refigerator and is VERY vulnerable to breakage when the box is pushed backagainst a wall space! Placing a shim under the vertical part of the fill tube fixed the problem even without replacing it with the new part. So, now I have a spare!
Was this helpful?
Thank you for voting!
Broken shelf support
9 of 10 people
found this instruction helpful.
-
Arthur from West Chicago, IL
- Really Easy
- Less than 15 mins
snapped in. The best part was the ease that i identified the part due to your website.
Was this helpful?
Thank you for voting!
THERMOSTAT
9 of 10 people
found this instruction helpful.
-
dominique from COMPTON, CA
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working
... Read more
like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Read less
Was this helpful?
Thank you for voting!
water collecting under the vegatable drawers
9 of 10 people
found this instruction helpful.
-
Gary from BILLERICA, MA
- Very Easy
- 30 - 60 mins
-
Screw drivers
I replaced the bi-metal thermostat. Very easy fix. It took a couple of days and the water stopped collecting at the bottom.I am very pleased with the web site.
Was this helpful?
Thank you for voting!
ice maker, intermittent hollow cubes, then no ice
9 of 11 people
found this instruction helpful.
-
paul from madison, WI
- Really Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers, Wrench (Adjustable)
I was not sure what was causing the problem, I thought at first it was low water pressure causing the hollow ice cubes. After some trial and error testing I figured a likely cause could be the water valve in the ice maker itself. I replaced that part rather easily using the existing fasteners in about 15 or 20 minutes. The ice maker ha
... Read more
s been working flawlessly since the repair.
Read less
Was this helpful?
Thank you for voting!
Ice buildup on the bottom of the freezer, water dripping into the refrigerator
8 of 9 people
found this instruction helpful.
-
Craig from Rockledge, FL
- Easy
- More than 2 hours
-
Nutdriver
After unplugging the refrigerator, I used a hairdryer to melt the ice sufficiently to be able to remove the freezer rear panel with a nutdriver. I also removed the ice-maker for easier access to the components behind the panel, using a nutdriver. Once the panel was removed I melted more ice at the bottom of the evaporator housing. Afte
... Read more
r partially melting the ice in the drain tube, I poured hot water down the drain tube until it cleared, signaled by the sound of the water dripping into the drain pan. I next removed the clip-on Bimetal thermostat from the copper line going into the evaporator and snipped the two wires to remove it. I installed the replacement thermostat with crimp-style connectors and pull-tested them. I also replaced the timer board that is located below the freezer, below the top shelf, using a nutdriver. I replaced the circuit board as a precaution that the thermostat may not have caused the problem. I didn't change the heater inside the freezer as it checked out to have the same resistance as a new one. I tested the removed thermostat using a glass of ice water but it remained in the open condition, using an ohmmeter. (I later checked that thermostat after the freezer was running and it did close, and returned it to the open position by heating it under the hot water faucet. I suspect that it didn't work properly, or the timer control board was faulty). After re-installing the back panel and ice-maker and plugging the refrigerator into the power receptacle, it worked very well, and has done so since the repair.
Read less
Was this helpful?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
10 of 16 people
found this instruction helpful.
-
Jorge from Miami, FL
- Easy
- 15 - 30 mins
-
Nutdriver
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burn
... Read more
ed. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Read less
Was this helpful?
Thank you for voting!
The Freezer was cold but the refrigerator was warm. The Fan motor had gone out.
7 of 7 people
found this instruction helpful.
-
Thomas from GATESVILLE, TX
- Easy
- 15 - 30 mins
-
Nutdriver
It was very easy and I'm not a handyman by any stretch of the imagination. I just removed the back inside panel of the freezer. The I unscrewed the fan mounting bracket. Unclipped the wires. Removed the old fan blade and put it on the new motor. I then attached the wires to the new motor and secured it with the old mounting brackets.
... Read more
I then replaced the back panel. The fridge is working like new now.
Read less
Was this helpful?
Thank you for voting!
fan making bad bearing noise
8 of 11 people
found this instruction helpful.
-
Bruce from Malvern, OH
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers, Socket set
r&r fan blade and motor. with the parts you supplied it was easy. the parts were perrrrfect. thank you very much. job well done. bruce
Was this helpful?
Thank you for voting!
Freezer No Longer Cools
7 of 8 people
found this instruction helpful.
-
STEPHEN from FENTON, MO
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Screw drivers
Our spare 25+ year old Kitchenaid refrigerator (side-by-side model) refused to produce cold air. I could hear mechanical sounds and things "clicking", but the temps kept raising. This specific unit only had cooling coils in the freezer, and some ducts that route cold air into the fridge.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
I emptied the refrigerator completely, ... Read more removed the ice cube bin and shelves, and left it unplugged for two days with the doors open. Once everything was dry, I plugged the unit back in -- within 8-10 hours, the unit was cold again. Lights worked, and fans in the freezer and back of unit worked. However... once the compressor turned off, it never came back on. This told me that the root cause lies with components that control when to turn off/on the cold flowing into the coils.
I looked up my model on PartSelect website, and looked through their "likely to fail" list for my model. The defrost thermostat and defrost timer were at the top of the list, and symptoms made sense. Those two parts arrived within a week. The defrost timer was easy to install -- unplug old, plug in new. The defrost thermostat involved cutting existing wires, stripping a small section of sheathing, and attaching the wires to the new part with crimp caps and electrical tape. The electrical tape was there to cover the exposed area of the crimp cap and bundle the wires together. (I used 3M's "Super 33+".) Finally, reattach the harness to the socket, and attach the other plugs and grounding clamp.
After re-attaching the rest of the required components, I plugged the unit back in. After about 24 hours, it had gone through at least one cycle and was appropriately cold. After letting it churn for another couple days and watching it closely, I felt confident that the problem had been fixed.
** Side Notes **
Definitely use caution around the fins on the coil. For my unit, the harness plug is directly above the fins, and required some effort to safely remove while not slicing up my hands. Extra long screwdrivers and patience helps a lot. Put a wedge behind the wheels of the refrigerator so that it doesn't back away from you while you work. And, of course, do all this while it is unplugged.
** For the PartSelect Website Maintainers **
If possible, please provide some better guidance on where to place the lead coming off the defrost timer. The Youtube video was nice, but some clarity on which pole/spade to attach it to (and where to find that info, besides "consult your manual") would help many people.
Read less