Refrigerator too warm, freezer coil iced up
52 of 64 people found this instruction helpful.
  • Jim from Lynn, IN
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers, Socket set
Unplug the refrigerator first,then Remove shelves and back inside cover from the freezer. Cut old bi-metal thermostat off and installed a new one. This fixed the problem. Ordered a new timer also which I didn,t need but installed it any way. On the fridge side ,top front, removed the knobs and cover, R&R timer, ins talled cover and knobs. Pay close attention to the instructions on where to put the black wire on the new timer. My refrigerator works great now. This was easy to repair if you are handy with electrical and mechanical repairs, if not get some help.
Was this helpful?
Thank you for voting!
took out the bottom glass shelf to clean and it just exploded on me when I went to dry it.
46 of 51 people found this instruction helpful.
  • suzanne from cheektowaga, NY
  • Really Easy
  • Less than 15 mins
Glass sheet came in perfect condition, just put back in refrigerator and has been fine ever since. Not the first time I had ever taken out to clean, but it will be the last. From now on, I clean it in the refrigerator.
Was this helpful?
Thank you for voting!
refrigerator stopped cooling, otherwise fine
48 of 59 people found this instruction helpful.
  • Roger from Bethesda, MD
  • Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
Well first of all, I was afraid that the compressor was shot and I'd need a whole new refrigerator (ack $1000!!!). After googling/reading, I figured out that the starter relay mounted on the compressor was burned out. (loud click as thermal cutout shuts down compressor.) So, I ordered a replacement part, overnight shipping. Unfortunately, this was on a Friday night, so I had to figure out how to keep the fridge cold all weekend (til Tuesday). I'd already moved frozen stuff to a chest freezer, but the inside of the fridge compartment was now nearly warm at this point, so I got 10 lb of dry ice. That got things cooled down initially. Well, turns out that with a short piece of wire, you can momentarily jump across the terminals of the relay and kick start the compressor. It then runs until either the defrost cycle stops it or the thermostat kicks it off. Anyway, all weekend, every six hours or so, I turned off the fridge for a minute to cool down the overheated, stalled compressor, then turned it on and jumped the terminals to start it up. Kind of a pain, but saved lots of food. Overall, the $30+$30 (shipping) for the part saved me from having to get a new refrigerator, so I'm quite pleased. I've used Part Select many times now. Very fast service and shipping, great website/database. I shop around and every time end up buying from them again.
Was this helpful?
Thank you for voting!
The freezer section was working fine. Not properly cooling the refrigerator
45 of 52 people found this instruction helpful.
  • Donald from Waco, TX
  • Easy
  • 30 - 60 mins
  • Screw drivers
I looked on line to see what was causes of the problem and determined that it was probably the fan in the freezer not working. I took the back section of the freezer apart and saw the fan was not running. I checked the parts on line and found that it was availiable and ordered a new fan motor. The blade looked fine, but I ordered a gro mmet anyway to ensure that there was no vibration problems causing the fan motor to go out. When the fan motor arrived, I began disconnecting the old one after unpluging the refridgerator and noting the terminals for the wires. The wire terminals were in a slightly different location, but reasoned out which wire belonged to the correct location. I pulled the old fan motor out, switched out the fan blade and grommet and re-incerted the new fan motor. I reconnected the wires and re-assembled the rear wall of the freezer. I plugged in the refridgerator and wa-la! It worked.
Was this helpful?
Thank you for voting!
old condenser fan motor shaft was loose and it made the spinning fan blades shake and cause noise
40 of 44 people found this instruction helpful.
  • Christopher from Snow Camp, NC
  • Easy
  • 15 - 30 mins
  • Screw drivers, Wrench set
The procedure was straightforward. I removed the cardboard backing on the lower back of the refrigerator to expose the fan unit. I then undid the electrical harness at the fan. I then removed the three screws securing the fan motor to the metal bracket. This is the hardest part in that I had to reach through and get to the screws with my small tools. I then removed the old motor and blades and placed the new motor and blades. Again, a bit tricky trying to get the three screws mounted into the bracket...small tools and hands helps. After that I used the electrical harness supplied with the kit to plug into the new motor and I was done.
Was this helpful?
Thank you for voting!
freezer froze up refridge not cold
39 of 45 people found this instruction helpful.
  • Benjamin from Mahanoy Plane, PA
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I unplugged the fridge.Removed the thermostat casing located in the lower part of the refridgerator by removing a few screws. disconnected the wiring plug from the relay board-connected the new board-screwed the new board inplace-put the casing back and replaced those screws. turned fridge back on and HOORAY off we went. i want to add fri nding the part and recieving it so quickly was also part of a great savings to me!
Was this helpful?
Thank you for voting!
Timer "clicking", indicating worn gears
38 of 43 people found this instruction helpful.
  • John from Plano, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
1. Unplug refrigerator to remove power!
2. The timer is inside the control housing located at the top of the refrigerator compartment.
3. Remove two control knobs (the pull off).
4. Remove the front panel escutcheon. The panel is not held in place with screws, but can be gently pried off.
5. Remove two screws from the back that hold the housing in place.
6. Remove screws from the front that hold the housing in place.
7. Drop housing down (still attached by wires - do not detach). Timer is inside housing, located on right.
8. Follow the instructions provided to identify your particular wiring setup. You'll find the wiring diagram (on my model) at the bottom of the refrigerator, alongside the defrost catch pan, behind the airflow grille.
9. Remove connector from timer terminals (4).
10. Remove two screws/nuts that hold the timer in place.
11. Install replacement timer following included directions. Read and follow ALL instructions applicable to your particular model and wiring setup.
12. Reassemble by reversing the steps above.
13. Note: You may need to "jog" the replacement timer when you first plug the refrigerator back in, if the timer happens to be in a "defrost cycle" (the compressor won't start). This can be done by inserting a wide bladed screwdriver into the hole below the timer, aligning it with the timer shaft, and slightly turning the shaft CW. Don't force it, and don't turn it very far.
Was this helpful?
Thank you for voting!
Freezer was cold, refrigerator was not.
33 of 33 people found this instruction helpful.
  • Michael from Oak Creek, WI
  • Easy
  • 15 - 30 mins
  • Screw drivers
After noticing my freezer was ice cold and the refrigerator was luke warm, I figured there was an airflow problem due to either a fan that failed or the evaporator coil iced over. Just by opening the freezer door I could hear the fan blowing so it had to be the evap coil. Sure enough after removing a couple screws and the back panel I sa w the ice. I then unplugged the frige to let it thaw overnight. In the morning I inspected the coil and luckily noticed right away that this little piece didn't look right. The top of the bi-metal thermostat was raised up. Almost like it popped. I read the other reviews on this website reffering to using an ohm meter to see if it held continuity. Well it didn't because the piece really did "pop". The wire was severed. So the ohm reader read open even if the piece was warm. I ordered the part and in days was able to replace the part. NOTE TO BUYER. It did not come with electrical connecting nuts or whatever they are called. So you'll have to go to the hardware store and pick some up for about $2. Frige works fine now. Thanks parts select.
Was this helpful?
Thank you for voting!
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
38 of 48 people found this instruction helpful.
  • James from Ringoes, NJ
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
Was this helpful?
Thank you for voting!
Light Switch broke
48 of 78 people found this instruction helpful.
  • James Richard from St. Cloud, MN
  • Easy
  • Less than 15 mins
  • Socket set
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
Was this helpful?
Thank you for voting!
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
38 of 50 people found this instruction helpful.
  • Robert from Doral, FL
  • Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Was this helpful?
Thank you for voting!
Freezer wasen't cooling refrigerator
36 of 45 people found this instruction helpful.
  • Joann from ATCHISON, KS
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed the old defrost heater screws and connected the new one. I have 46 apartment units here and have had about 15 defrost heater's replaced by service repair person at a very expensive cost. To my surprise it was extremly easy and a lot less in cost.
Was this helpful?
Thank you for voting!
Water was dripping from the freezer into the non-frozen area, and the non-frozen area was not cooling
34 of 43 people found this instruction helpful.
  • A. M. from Bay Minette, AL
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I first disconnected the power cord and then removed all the panels and disconnected the Defrost Heater at the quick-disconnect, and cut the wires on the Defrost Themostat. (The Defrost Thermostat had been replaced about 10 years ago when the Defrost Heater was replaced.) One of the reasons it took longer than 15 minutes was because ther e was a buildup of ice in the freezer section. I then soldered the wires and covered them with a plastic sleeve and wrapped them in electrical tape. After replacing all the panels and re-connecting the power cord, I restarted the refrigerator. After one week, there is no water dripping from the freezer and everything is working properly. Your diagnosis of the problem was exactly right. Thanks for the info.
Was this helpful?
Thank you for voting!
Evaporator Motor burned out
30 of 35 people found this instruction helpful.
  • Max from Waco, TX
  • Easy
  • Less than 15 mins
  • Nutdriver
Very pleased with the delivery time. Was able to repair the refrigerator before the beer got hot. Replacement was easy.
Removed blower housing. Replaced motor. Put blower housing back in place.
Was this helpful?
Thank you for voting!
thermostat swicth
37 of 56 people found this instruction helpful.
  • lonnie from defiance, OH
  • Really Easy
  • Less than 15 mins
  • Screw drivers
change it
Was this helpful?
Thank you for voting!
All Instructions for the 106629