Both freezer and refrigerator stopped cooling
224 of 281 people found this instruction helpful.
  • Laune from Front Worth, TX
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Compressor Start Divice kit, I took off back lower panel with the 1/4 inch nut driver, on the compressor their was a wire hook that held the starter in place used my plyers to unhook, pulled the unit off plug the new unit in reappled the clip it was so easy I had to exame it severl to time to make sure that was all their was to it. put th e cover back on and turn the refrigerator on and it has work great, I did not install the Bi-Metal Defrost Thermostat it was not needed.
Was this helpful?
Thank you for voting!
Seven year old condenser fan was making noise when it was running.
199 of 211 people found this instruction helpful.
  • Josue from Jacksonville, NC
  • Really Easy
  • Less than 15 mins
  • Screw drivers
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
Was this helpful?
Thank you for voting!
No Ice in the Ice Maker
201 of 237 people found this instruction helpful.
  • Chris from Duluth, GA
  • Really Easy
  • Less than 15 mins
  • Socket set
I am NOT a handyman, and my family laughed at me when I said I was going to fix the ice maker all by myself. I ordered a replacement ice maker. When it arrived, I opened the box and read the instructions. It seemed easy. I removed the old ice maker, with a socket set. I then took off the shut off lever from the old one and placed it on the new one, since the new one didn't come with it. I then put the new one in place. All the parts fit perfectly. The ice machine was making ice within an hour. My family was amazed... and I got the last laugh!
Was this helpful?
Thank you for voting!
Plastic bits dispensed from Ice Dispenser in Door
205 of 254 people found this instruction helpful.
  • john from seaford, VA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers, Socket set
Removed Ice bin from Fridge

Removed all bolts on bin with nut driver...about six

Removed housing...be careful with spring on crusher/cube control rod

Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.

Removed plastic nut on end of auger shaft

Remov ed Ice crusher jaws and laid them out in the correct order

Removed Ice propeller and installed new part

Put back together in opposite order

Easy
Was this helpful?
Thank you for voting!
Ice Maker would not stop making ice.
194 of 222 people found this instruction helpful.
  • Vince from El Cajon, CA
  • Really Easy
  • Less than 15 mins
  • Screw drivers
First, I tested the ice maker "switch" that actually just covers the beam that regulates the ice maker. In the "off" position, it still made ice. Then, I removed the three screws on the cover over the transmitter and disconnected the circuit board at the wire connector. It stopped. After ordering and receiving the new transmitter and rece iver boards, I replaced both boards. They are located on either side of the freezer compartment under panels held in place by three screws. Probably saved 150 to 200 bucks.
Was this helpful?
Thank you for voting!
Clicking from underneath the fridge, and compressor engaging only intermittently
198 of 239 people found this instruction helpful.
  • Michael from Manvel, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I diagnosed the problem as a bad relay. I detached the two sets of wires leading to the relay and compressor, then pulled the relay off the compressor. It rattled and small bits of detritus fell out from inside of the relay. The new relay came the next day. It did not rattle. It was identical and I simply did the reverse to reinstall.
Was this helpful?
Thank you for voting!
External Ice Guide Broke a Tooth and Fell Off
170 of 186 people found this instruction helpful.
  • Tracy from Jacksonville, FL
  • Really Easy
  • Less than 15 mins
We waited two years to do this because we didn't want to hassle with a repair man to come out and charge us arm+leg for something so simple. Finally we searched and found the part on line. It came two days FASTER than promised. Kudos to Part Select.
Snapping it on was a breeze, although you do have to apply more pressure than feels comfortable with plastic clips. We can know get ice out of the external door system again.
Was this helpful?
Thank you for voting!
Ice maker would't fill with water
169 of 185 people found this instruction helpful.
  • Jerry from Cooper City, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
I first read your forum which was extremely helpful! I checked the continuity of the electromagnetic valve and got a 0 reading on the ice fill valve. The valve next to it which is for the water in the door had a 300ohm reading on my meter. This meant there was a broken wire somewhere in the coil which confirmed the valve was bad. I tried to get the part locally but was told it was on back order! Ordered it thru Part Select at the regular shipping rates and to my surprise it arrived the very next day!
The valve was the new style where you push in the tubing until it locks. I carefully trimmed each tube square with a sharp razor knife, the old valve used plastic compression fittings which had to be cut off.One of the inlet tubes was smaller than the opening on the valve. I then noticed that there was a reducer in the box that snapped into place making the line a perfect fit! Even though the inlet valve looked different than the original it was an easy installation. After replacing it, I had ice again! Totally impressed with the service and how quickly they shipped the parts on the same day! I will never again run around town trying to find parts! Thanks to all of the hard working employees at Part Select!
Was this helpful?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
159 of 188 people found this instruction helpful.
  • Cathy from Winter Park, FL
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Was this helpful?
Thank you for voting!
The Water Dispensor Tubing Had Become Brittle And Broke .
209 of 347 people found this instruction helpful.
  • Conrad from Tucson, AZ
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
Removed the face plate. Removed a few screws and unpluged a few electrical connectors and pulled apart. Removed the holding bracket and clear tubing from door. Cut new tubing at an angle to push through conduit. Reinstalled new bracket and re-installed electrical connectors. Snapped face trim on and bleed air out of system. . W ater ran great.
Was this helpful?
Thank you for voting!
Pur Water filter ruptured could not remove from housing
191 of 305 people found this instruction helpful.
  • George from Hernando, MS
  • Easy
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
Removed two screws holding the filter housing. Pulled filter and housing out far enough to remove inlet and outlet lines.Replaced inlet and outlet lines( precautionary) in filter housing, installed new filter.
Was this helpful?
Thank you for voting!
Refrigerator Door quit closing on it's own......
140 of 153 people found this instruction helpful.
  • T.w. from Batesville, AR
  • Easy
  • 15 - 30 mins
  • Pliers, Socket set
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
Was this helpful?
Thank you for voting!
Ice Maker stopped working
135 of 154 people found this instruction helpful.
  • Robert from Port Washington, NY
  • Really Easy
  • 15 - 30 mins
  • Screw drivers, Socket set
With socket wrench un-screwed the 3 screws and pulled out the ice maker assembly.

Pulled off white plastic end-cap and noticed the plastic gear disk had snapped off (sub part # R0167202)

However, it is all-one-part of the motor assembly unit # w10190935 (part # PS2341896) which must be ordered as a complete part. ... Read more />
Unscrewed the motor assembly (3 screws) with phillips head screw driver.

Screwed in the new unit.

Placed ice maker back into location and tightend the bacing srews.

1 hour later ice was falling!
Was this helpful?
Thank you for voting!
Broken elbow on icemaker water fill tube.
130 of 142 people found this instruction helpful.
  • Charles from Orland Hills, IL
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Removed 2 screws holding water fill tube to rear of refrigerator and pulled out, matched old part with new to make sure of proper match. Guide new fill tube thru hole, making sure it is aligned with slot in ice cube tray on inside of freezer. Install new plastic line from water pump outlet to water fill tube, check for leaks, job done.
Was this helpful?
Thank you for voting!
Refrigerator too warm, freezer fine
145 of 197 people found this instruction helpful.
  • Bill from Andover, MA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Screw drivers
I replaced the Diffuser and the Thermistor (the one in the refrigerator) at the same time. I was not sure what the problem was ahead of time except for the fact that no air was coming in from the freezer section; this is where the air diffuser is. I probably only needed to replace the diffuser.

I turned the circuit breaker fo r the refrigerator off. There was a small section of plastic covering the wires that run from the top console inside the refrigerator to the back of the refrigerator where the diffuser is. I took this off (one screw) and then the diffuser is connected in the refrigerator side with one screw. To push the diffuser from the freezer, I needed to take off a piece of plastic directing the flow of air from the freezer. I needed to move the ice maker forward a little; it moves forward easily (it sort of clips into place). Once the diffuser was visible from the freezer, I pushed it out or disconnected the four clips holding it in and it came right out. Once this is done, you simply unplug the old and plug in the new and put back in place. This took less than 15 minutes total time. Online diagrams makes ordering parts and fixing easy.

Once the new diffuser was in, I could tell I was golden because I was getting cold air. I guess this piece goes bad from time to time based on others experiences.
Was this helpful?
Thank you for voting!