Plastic bits dispensed from Ice Dispenser in Door
205 of 254 people
found this instruction helpful.
-
john from seaford, VA
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers, Socket set
Removed Ice bin from Fridge
Removed all bolts on bin with nut driver...about six
Removed housing...be careful with spring on crusher/cube control rod
Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.
Removed plastic nut on end of auger shaft
Remov ... Read more ed Ice crusher jaws and laid them out in the correct order
Removed Ice propeller and installed new part
Put back together in opposite order
Easy
Removed all bolts on bin with nut driver...about six
Removed housing...be careful with spring on crusher/cube control rod
Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.
Removed plastic nut on end of auger shaft
Remov ... Read more ed Ice crusher jaws and laid them out in the correct order
Removed Ice propeller and installed new part
Put back together in opposite order
Easy
Read less
Was this helpful?
Thank you for voting!
Fridge was getting too warm, ice buildup on coils.
159 of 188 people
found this instruction helpful.
-
Cathy from Winter Park, FL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ... Read more ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.
Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket
Steps:
1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.
2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.
3: Un-clip the bi-metal strip from the evaporator coils.
4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.
5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.
6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.
7: Do the same for the ends of the wires on the (new) bi-metal strip.
8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.
9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.
10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.
11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.
12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).
13: Replace the panel that covers the coils.
14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
Read less
Was this helpful?
Thank you for voting!
Broken light switch
81 of 133 people
found this instruction helpful.
-
Randy from Hays, KS
- Really Easy
- 15 - 30 mins
-
Socket set
Took all the screws out of the plastic shroud that encloses the switch .There only four that I needed to remove, were the two in front where the switches that go,they go in horizontally and two in the back with large washers on them that hold the back to the top of the box that go in vertically.The switch was a snap ( make that two snaps
... Read more
) the wiring is almost self explanatory. then it gos back to the way you took it off. OH! and don't forget to turn the light bulb all the way back in to the socket , so the light will work after you take the time to install it yourself.I had the water supply line from under the box to the water dispenser in the door and the total bill on that was one hundred thirty seven and a hand full of change.Don't be afraid to do it yourself the savings is enough on one one item to make several months payments on a new one Randy the "Handy Man'
Read less
Was this helpful?
Thank you for voting!
plastic Ice bin auger broke and needed to be replaced
56 of 67 people
found this instruction helpful.
-
Suzanne from Colorado Springs, CO
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
The repair was actually easy; however I have an ice dispencer/crusher attached and the which the diagram supplied with the part did not include. I had to make several calls before I was e-mailed the diagram.
Suggestions: note that the screw at the end of the auger goes in the reverse direction (this took me about 20 minutes to fi ... Read more gure out even though it was shown in the diagram). Also, be sure to keep the ice crusher parts in order and be sure the white plastic tab on the crusher fits into a depression in the housing. I did not notice this and had to take it all apart and redo the install. It works great!!!
Suggestions: note that the screw at the end of the auger goes in the reverse direction (this took me about 20 minutes to fi ... Read more gure out even though it was shown in the diagram). Also, be sure to keep the ice crusher parts in order and be sure the white plastic tab on the crusher fits into a depression in the housing. I did not notice this and had to take it all apart and redo the install. It works great!!!
Read less
Was this helpful?
Thank you for voting!
Worn out door plastic cam
36 of 38 people
found this instruction helpful.
-
ROGER from WAXHAW, NC
- Really Easy
- 15 - 30 mins
-
Nutdriver
Replaced the door cam on bottom of fridge door. ONE THING TO UNDERSTAND- THERE ARE 2 CAMS ON THE DOOR, LOWER AND UPPER, BUT THE UPPER CAM IS NOT LISTED ON THE "DOOR HARDWARE" DRAWING, ITS LISTED ON THE MAIN BODY DRAWING! BE SURE TO GET BOTH CAMS! (PARTSELECT COULD MAKE A NOTE THAT WHEN PEOPLE LOOK UP LOWER CAM, PUT A NOTE IN THERE SAYING
... Read more
Y0U NEED UPPER TOO!)So I had to order the upper cam later and install later. BUT it is quite easy to replace, unlike the video, I only needed 1 tool! The nut driver (electric screwdriver w nut driver head). Thanks -RF
Read less
Was this helpful?
Thank you for voting!
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
38 of 48 people
found this instruction helpful.
-
James from Ringoes, NJ
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat.
... Read more
Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
-James
Read less
Was this helpful?
Thank you for voting!
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
38 of 50 people
found this instruction helpful.
-
Robert from Doral, FL
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of
... Read more
the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
Read less
Was this helpful?
Thank you for voting!
Had to replace a hose connector at the base of my refrig/frreezer
47 of 81 people
found this instruction helpful.
-
Leo from Salem, SC
- Really Easy
- Less than 15 mins
Perhaps a helpful hint:
When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.
LG
When aI received the hose adapter/connector, I inserted the 2 hose ends only to have water drip from the connection.
I used a utility knife to remove an inch from each side, then reinserted the hoses. That made the differnce. Dry as a bone.
LG
Was this helpful?
Thank you for voting!
Ice maker would only deliver crushed ice not cube's
36 of 54 people
found this instruction helpful.
-
MICHAEL from NORTH PORT, FL
- Easy
- 15 - 30 mins
-
Screw drivers, Socket set
Switched Electric breaker to off. Removed all food and ice cube tray from freezer. Remove 4 screws on soleniod cover in rear of freezer. Removed two screws, two elec connectors from old soleniod and removed. Installed new soleniod. Reinstalled elec connectors and screws, ice cube tray and food. Turned breaker on . Ice maker worked properl
... Read more
y.
Read less
Was this helpful?
Thank you for voting!
Old filter and water line to cold water line
28 of 37 people
found this instruction helpful.
-
James from Phelan, CA
- Easy
- 15 - 30 mins
Cut a 1/4 inch off both lines and connect. Changed water filter. Found the water filter at Home Depot for 1/2 The price. Look befor you buy.
Other Parts Used:
Was this helpful?
Thank you for voting!
broken meat and vegatable draw
25 of 28 people
found this instruction helpful.
-
douglas g. from roanoke, VA
- Really Easy
- Less than 15 mins
a simple replacement
Was this helpful?
Thank you for voting!
motor coupling weld broken
24 of 26 people
found this instruction helpful.
-
HAROLD from SPRING HOPE, NC
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers
Removed four screws from ice maker motor/light support.Then unplugged electrical plug from side of freezer.Used two slip joint pliers to remove coupler from motor shaft. installed new coupler to shaft hand tight as will tighten as motor is run.Then reversed tear down order.
Ice dispenser works better than when we first got the refrig ... Read more erator
Ice dispenser works better than when we first got the refrig ... Read more erator
Read less
Was this helpful?
Thank you for voting!
Cracked Evaporation tray was leaking water on kitchen floor
26 of 34 people
found this instruction helpful.
-
Jerrel from REDDING, CA
- A Bit Difficult
- 30 - 60 mins
-
Socket set, Wrench (Adjustable)
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the
... Read more
panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
Read less
Was this helpful?
Thank you for voting!
Refrigerator door failing to close without being pushed shut
25 of 32 people
found this instruction helpful.
-
Kenneth from Greeley, CO
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver, Pliers
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
Other Parts Used:
Was this helpful?
Thank you for voting!
broken drawer
22 of 24 people
found this instruction helpful.
-
Jason from Farmland, IN
- Really Easy
- Less than 15 mins
Put new drawer in fridge.
Was this helpful?