The refrigerator side of the appliance did not cool
22 of 27 people found this instruction helpful.
  • juan from Weslaco, TX
  • A Bit Difficult
  • 30 - 60 mins
  • Screw drivers
I discovered that the freezer was not defrosting automatically and the condenser coil was freezing up blocking the flow of cold air to the refrigerator side. I first replaced the thermostat thinking that it would be an easy fix but needless to say it didn't work. My indicator that it was not a successful repair was the continuing blinking of the filter change light on the control panel. Ultimately I had to replace the control board assembly to solve the issue.
Was this helpful?
Thank you for voting!
The auger drum had broken, not allowing any ice cubes to be crushed or dispenses through the door.
22 of 28 people found this instruction helpful.
  • Evan from Grand Rapids, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Initially I removed the cover to the auger and auger drum. Then the split ring locking washer had to be removed. I used a needle-nosed pliers and small screw-driver to pry that off. The auger arm could then be removed, and the auger blades removed. This proved to be the part that required the most patience. The blades need to removed and returned in their exact pattern. Someone else suggested taking a digital picture of them before removing them; this is a good suggestion that I failed to do. Once the blades are returned, all the other parts can be replaced in reverse order. Put the screws back in, and you are finished.
Was this helpful?
Thank you for voting!
Light cover was missing, Lite socket loose
19 of 20 people found this instruction helpful.
  • Wayne from Helendale, CA
  • Really Easy
  • Less than 15 mins
The light cover was missing so the shelf allowed for anything that was pushed back to hit the light, so the light socket broke out of the rear wall. I used expanding foam behind the light socket to glue it back into position, held really good. Then replaced the missing light cover. Another company told me the light cover was discontinued and no known supplies but Parts Select had it in stock no problems!
Was this helpful?
Thank you for voting!
Refrigeator would not drfrost...
27 of 44 people found this instruction helpful.
  • Curtis from Pikeville, KY
  • A Bit Difficult
  • 1- 2 hours
  • Pliers, Screw drivers, Socket set, Wrench set
I just removed a few screews and took the cover out of the ice box. Put my voltage meter to the refrigeator and realized the the unit was not defrosting...I then got the part number and entered it in on your web site. A few days later my part arrived. I put the part on and in just about 20 minutes I was up an running again...Thank you Part Select for fast and great service. I own 35 rental properties and having a online appliance parts store really saves me a lot of time and money.

Thank you
Curtis Hall
Was this helpful?
Thank you for voting!
refrigerator would not stay cold
21 of 26 people found this instruction helpful.
  • Allan from Allen, TX
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The wife found if we tapped the knob for the cold control the appliance would turn on. Upon further inspection I found what looked to be carbon particles under the part. I found the part easily with partselect.com, ordered it, installed it and its like we have a new appliance.
Was this helpful?
Thank you for voting!
The old resevoir needed to be replaced
35 of 68 people found this instruction helpful.
  • Fred from Martinsburg, WV
  • Really Easy
  • 15 - 30 mins
  • Pliers, Socket set
The repair was incredibly easy -
1. Turn off the water at the water line for the fridge
2. Disconnect the pressure fittings for both lines running to the resevoir.
3. Remove the old resevoir
4. Install the new resevoir and run the lines back to the orginal fittings.
5. Reconnect the fittings, turn on water.< br />6. Drink water!
Was this helpful?
Thank you for voting!
Smelled Electrical Burning / Smoke
26 of 42 people found this instruction helpful.
  • Stephen from Holt, MI
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver
Removed cardboard back from refrig. Found source of smell/burn. Removed part. Ordered several replacement parts as the diagram was not clear as to which part would be needed. New parts arrived, matched with old. Cleaned carbon from contacts, installed new part. Cleaned dust from refrigeration coils, installed back. Returned unused p arts.
Was this helpful?
Thank you for voting!
ice would not fall from ice maker
22 of 30 people found this instruction helpful.
  • Greg from Cary, NC
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I ran all the ice maker module tests that I could find online, I tried cleaning the contacts inside the ice maker control module, nothing worked...so I finally decided to purchase a new control module. I had already had the module out and taken apart a few times, so the new one was very easy to install. Just removed the entire icemaker from the fridge, removed a few screws, took off the old module, put on the new one, replaced the screws, re-installed the icemaker in the fridge (it just slides in and out similar to a shelf). And 30 minutes later I heard the first batch of ice cubes drop! And by morning the bucket was nearly full. After two weeks of no ice and trying to fix it myself - the family was glad to have ice again (it was July in NC!). In retrospect, I should have followed the advice I found online and ordered the new part sooner and saved all of those frustrating hours of trying to "fix" the part myself.
Was this helpful?
Thank you for voting!
Clogged Ice shoot in freezer door (curshed ice)
20 of 25 people found this instruction helpful.
  • Lue from Wichita, KS
  • Easy
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
First remove the ice container from the freezer
and dump all of the ice. Remove the four
screws holding the front ice container cover. Remove the control arm screw and bracket from the bottom of the ice container, remove crusher housing (screws and retainer clip). Remove nylon
bearing nut on front of auger shaft (left ha nded threads). Remove crusher blades and spacers (remember order of blades and spacers). Remove broken floating baffle. Replace baffle and reverse removal procedures.
Was this helpful?
Thank you for voting!
Ice maker would not dispense ice
20 of 25 people found this instruction helpful.
  • William from Victorville, CA
  • Easy
  • 15 - 30 mins
  • Nutdriver
1. Removed Ice cube bin. 2. Removed the 4 screws holding dispenser bracket in place. 3.Unplugged electrical connector for motor and removed the unit. 4. Removed the coupler,wiring connections and three screws holding dispenser motor to mounting bracket. 5.Installed new dispenser motor onto bracket, put on coupler and connected wiring to m otor. 6. Installed newly assembled unit put ice bin back into place. Dispenser works great.
Was this helpful?
Thank you for voting!
Over flowing Icemaker
21 of 29 people found this instruction helpful.
  • Thomas from Flower Mound, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray.
After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later.
Over flowed and iceberg would form at rear.
Replaced icemaker unit and works fine now.
Was this helpful?
Thank you for voting!
Ice door holder arm broken
20 of 26 people found this instruction helpful.
  • Joseph S from Las Vegas, NV
  • Easy
  • 15 - 30 mins
  • Nutdriver
The hardest part was getting the front cover plate off. I used two kitchen knifes one in each slot on the bottom of the plate and pried it off and unplug it. I removed one screw to release arm. I then used long nose pliers to remove the pin on door arm assemble. Then unplug door heater. New door has no heater. The heater had cooked the pl astic arm, which caused the arm to fail. Then reassemble in reverse order.
Was this helpful?
Thank you for voting!
drawer broke from kids overloading it.
20 of 27 people found this instruction helpful.
  • jonathan from sugar hill, GA
  • Really Easy
  • Less than 15 mins
Pulled out the old drawer and put in the new.
Was this helpful?
Thank you for voting!
Water leaking from under refrigerator.
17 of 18 people found this instruction helpful.
  • Ronald from DELRAN, NJ
  • Difficult
  • 1- 2 hours
  • Nutdriver, Screw drivers, Socket set
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for le ak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.

The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
Was this helpful?
Thank you for voting!
Unable to set the cold-control to a sufficiently cold setting.
36 of 75 people found this instruction helpful.
  • Leo from Lewisport, KY
  • Really Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
Linkage on the cold-control mechanism in the air diffuser assembly was broken. It was necessary to access the diffuser assembly from both the refrigerator and freezer sides of the unit.
Re-connected the linkage between the diffuser and cold-control assembly; remounted the two combined assemblies . . . refrigerator working nicely now .