Cracked Evaporation tray was leaking water on kitchen floor
26 of 34 people found this instruction helpful.
  • Jerrel from REDDING, CA
  • A Bit Difficult
  • 30 - 60 mins
  • Socket set, Wrench (Adjustable)
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
Was this helpful?
Thank you for voting!
The fan wasvery noisy.
23 of 26 people found this instruction helpful.
  • Tracy from Coppers City Bottom, WV
  • Easy
  • 15 - 30 mins
  • Screw drivers
Removed six screws from cover in the back of the freezer. Removed old fan . Removed power wires from old motor. Unclipped old motor from the mounting bracket. Replaced old motor and reversed the rest of the parts. Done
Was this helpful?
Thank you for voting!
Refrigerator door failing to close without being pushed shut
25 of 32 people found this instruction helpful.
  • Kenneth from Greeley, CO
  • A Bit Difficult
  • 15 - 30 mins
  • Nutdriver, Pliers
Replaced upper cam piece on bottom hinge and also replaced pivot thimble on upper hinge.
No problems, except pivot thimble glued in place. Had to cut up and pull out with pliers. Everything works like new now.
Was this helpful?
Thank you for voting!
broken drawer
22 of 24 people found this instruction helpful.
  • Jason from Farmland, IN
  • Really Easy
  • Less than 15 mins
Put new drawer in fridge.
Was this helpful?
Thank you for voting!
Noticed fridge not cooling as it should
21 of 21 people found this instruction helpful.
  • Robert from Franklin, TX
  • Really Easy
  • Less than 15 mins
  • Nutdriver
Removed the lower back panel (10 small screws)Found the condenser motor froze up and not moving air across the cooling coils.So I got a small table fan and set it behind the fridge and it kept the fridge cooling for 3 days till the new fan motor arrived. Removed 3 small screws holding the fan motor in the bracket and unpluged the wiring h arness.Removed the fan from old motor and used it on the new motor.Replaced the fan in the bracket and plugged the wiring harness back in. Worked great. Very easy.Did not have to empty fridge because table fan kept coils cool. Ordering part was easy and shipping fast.Great job guys!!
Was this helpful?
Thank you for voting!
in door water dispenser tube broken off 1.5 inches from end
23 of 27 people found this instruction helpful.
  • haig from La Quinta, CA
  • Really Easy
  • 15 - 30 mins
  • Pliers, Wrench set
shut off water supply behind fridge then released trapped water pressure in the line at the dispenser. Locked off dispenser controls (push button switch). Removed nozzle retaining screw and pulled out nozzle approx. 3 in. to cut off tubing at black pipe so as to use the old pipe as a guide/pull (fish) for the new pipe by joining the end o f the new nozzle to the cut and of the old pipe with electrical tape.Then pulled the old pipe from bottom of fridge while simultaneously feeding/pushing new pipe from top. I had to remove lower grate on fridge to access the pipe on bottom. Remaining coupling connection on bottom was done by hand to avoid stripping plastic coupling.
Was this helpful?
Thank you for voting!
Refrigerator and freezer not cold
23 of 28 people found this instruction helpful.
  • Lisa from League City, TX
  • Really Easy
  • Less than 15 mins
  • Pliers
I removed the back panel off the fridge and removed the old start relay device by simply unplugging it from the compressor. I had to detatch two wires and a capacitor from the device. The old start relay was definitely bad and you could tell by shaking it. Plugged in the new start relay device, reattached the wires and capacitor and wa s done. Fridge is perfect now! Very simple!
Was this helpful?
Thank you for voting!
Fridge side freezing everything.
21 of 22 people found this instruction helpful.
  • David from Murfreesboro, TN
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
The fridge side would freeze everything regardless of setting. First, unplug the unit. Remove control knobs and pry off the face plate which is snapped on. Remove the four nuts holding the control box to the top of the fridge. Note there is a mettle rod and the thermostat sensor lead inside a clear plastic tube leading from the control bo x to the back left corner of the fridge. Remove their cover (one screw). Under this cover in the back is the vent assembly screw. Remove it. On the freezer side, you also have to remove the light cover (snap on) and the vent cover behind it (one screw). This allows access to remove the vent on the fridge side. Squeeze the tabs on the vent(freezer side) that lock the vent in place and push it through to the fridge side. Now disconnect all wire connectors between the control box and the fridge. They have locking tabs that have to be pried out to release. Remove the two screws holding the thermostat to the control box, and one at a time transfer the wires from the old stat to the new one and mount the new one in place. Snap the old thermostat sensor lead out of the vent assembly, straighten it out and pull the plastic tube off. Put a lubricant on the new stat lead to ease in inserting it into the tube. Do not kink the lead. Re assemble in reverse order, plug up the fridge.
Was this helpful?
Thank you for voting!
ice distribution door broke
23 of 28 people found this instruction helpful.
  • David from Winston-Salem, NC
  • Really Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
At their site was ordering each piece by # and cost and it was adding up to be costly. Went to partselect and was doing the same and up pops the ice door kit. Was a little wary because my original had a heater tape to it. Got the kit and installed not a problem at all. 100% satisfied would recommend to anyone.
Was this helpful?
Thank you for voting!
There was a pin size hole in the tube.
25 of 34 people found this instruction helpful.
  • Julia from Seguin, TX
  • Easy
  • 30 - 60 mins
  • Screw drivers
It was pretty easy to install. The most difficult part was trying to get my hands into the small area to work. I had to use both hands, one to push the release in and the other to pull the tube out. Once I did that, inserting the tube was easy and everything worked perfectly.
Was this helpful?
Thank you for voting!
Plastic Water Spout Broke Off
21 of 23 people found this instruction helpful.
  • Michael from Colorado Springs, CO
  • Difficult
  • More than 2 hours
  • Nutdriver, Pliers, Screw drivers, Socket set
Turn off water supply line fridge. Removing front panel is a must to allow acces to spout and water line. Be careful not to crack front panel $90, it snaps in from the botton, slide a stiff putty knife along bottom edge and gently pry outward to remove. Remove 2 screws that hold spout in place, then cut water line right behind spout. The tricky part is fishing water line down through door. You need to splice new line to old with double sided screw or something with threads that will prevent the lines from pulling apart, then pull water line from bottom of door by hinge, very tight when pulling through hinge opening. You will need to remove vented dust cover at botton of doors to acces the water line. The line has a threaded coupling so unscrew and drain water then cut new line to length. There is a small metal insert in old line that needs to be removed and inserted into new line before attaching coupler. I could perform this in half the time now that I have done it once.
Was this helpful?
Thank you for voting!
Ice dispenser freezing up, dispenser door not closing completely.
22 of 26 people found this instruction helpful.
  • Robert from Valencia, CA
  • Easy
  • 30 - 60 mins
  • Nutdriver, Screw drivers
First off, if you have the stainless steel panel inserts on your refrigerator you'll need to remove those to do this repair. I kept looking for the access holes on the underside of the dispenser panel that you're supposed to insert a screwdriver into to pry it off. It wasn't until I removed the freezer door handle, slid the lower stainles s panel insert out, and removed the rail just beneath the dispenser that I could see and access these holes. I also removed the upper stainless panel and rail just above the dispenser to allow enough movement get the dispenser cover off and out. The rest of the repair is pretty straightforward. The old ice door was beaten up and not closing completely, this was letting warm air into the freezer which was melting and re-freezing. This kit fixed the problem.
Was this helpful?
Thank you for voting!
Ice dispensor motor would run but would not dispense ice at the door!
22 of 26 people found this instruction helpful.
  • Larry from Hague, ND
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Wrench (Adjustable)
To get the coupler off the motor shaft I took two adjustable wrenches and slit the old coupler where it was cracked.The threads on the motor shaft were stripped closest to the motor.I took two thin washers and put them on the motor shaft so the new coupler would not turn down to where the threads on the motor were sripped.Since the thread s on the coupler are left hand they keep the coupler tight as the motor turns the dispenser auger to dispense the ice.I was a bit difficult to unplug the wiring harness but got it after we used a screwdriver to keep the tab bent down until the harness was unplugged.
Was this helpful?
Thank you for voting!
Water filter end broke off so I could not get out of housing.
22 of 27 people found this instruction helpful.
  • William from Waxhaw, NC
  • Easy
  • Less than 15 mins
  • Wrench (Adjustable)
Removed 2 screws holding housing to frame. Pulled housing out 10 inches. Removed water lines. Attached water lines to new housing. Pushed back into place. Secured to frame with 2 screws. Put in new filter. DONE!
Was this helpful?
Thank you for voting!
The auger drum had broken, not allowing any ice cubes to be crushed or dispenses through the door.
22 of 28 people found this instruction helpful.
  • Evan from Grand Rapids, MI
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers, Screw drivers
Initially I removed the cover to the auger and auger drum. Then the split ring locking washer had to be removed. I used a needle-nosed pliers and small screw-driver to pry that off. The auger arm could then be removed, and the auger blades removed. This proved to be the part that required the most patience. The blades need to removed and returned in their exact pattern. Someone else suggested taking a digital picture of them before removing them; this is a good suggestion that I failed to do. Once the blades are returned, all the other parts can be replaced in reverse order. Put the screws back in, and you are finished.
Was this helpful?
Thank you for voting!