106410 Kenmore Refrigerator - Instructions
Search repair tips from other customers using simple keywords like "replace", "fit", "remove", "inspect". DIY doesn't mean you have to do it alone!
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Black Cam was bren on lower door hinge
6 of 7 people
found this instruction helpful.
-
Kyle from Wimauma, FL
- Very Easy
- 15 - 30 mins
-
Socket set
This was a very simple job. Remove the top Hinge bracket, a total of 4 screws, lifted the door off the bottom hinge, removed the bottom hinge set up, 2 screws, replaced it, and attached the new bottom black door cam, lifted the door back onto the bottom hinge and aligned the top hinge, and reinserted the screws, and Ta Da, The door works
... Read more
like a new refrigerator door. 15 to 30 min tops. I did not even have to take the refrigerator items out of there door holder.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Fan motor was making noise.
6 of 7 people
found this instruction helpful.
-
Harry from Mountain Iron, MN
- Easy
- 15 - 30 mins
-
Nutdriver, Screw drivers
First I removed all food in freezer.Then removed selves and hanger brackets.Then the back panel and light cover.Then I unplugged motor but before this I unplugged refrigerator from the wall.Removed motor from bracket after pulling of fan. Reversed the order to install motor and put back together
Other Parts Used:
Was this helpful?
Thank you for voting!
fridge and freezer stopped maintaining proper temp
5 of 5 people
found this instruction helpful.
-
Donald from CONWAY SPGS, KS
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
I followed the repair videos that were provided by partselect and installed a bi-metal defrost thermostat in the freezer and a thermostat assembly in the fridge. The installation was not hard and everything is now working as it should. Thanks
Other Parts Used:
Was this helpful?
Thank you for voting!
Noisy operation (from the inside)
5 of 5 people
found this instruction helpful.
-
Frederick from APEX, NC
- A Bit Difficult
- 30 - 60 mins
-
Nutdriver, Screw drivers
Unplug, then on the freezer side, remove the drawers, then remove the screws holding the sheet metal cover, remove the rails (for the drawer) that interfere with removing the sheet metal cover. pull the wires off the motor. There is a big plastic piece that holds a small plastic piece that holds the motor. Remove the plastic piece that h
... Read more
olds the motor/fan (you might be able to swap the motor by removing the little plastic piece that holds the motor, or you can remove the bigger piece and then remove the small piece that holds the motor). Pull the fan blade off (to reuse), swap the motor. NOTE - the new motor wire terminals may be on the opposite side of the motor vs. the old motor - that is not a problem - there is plenty of room for the wires. After the motor is installed put the fan blade back on, reinstall the removed plastic pieces in the back of the refrigerator. Now, I'd suggest a quick test. Make sure the new motor works and the fan blows before you button it up. Once you know it works, power it off, and put the sheet metal cover back on, reinstall the basket brackets, put the baskets back in place, close the door, and turn it back on.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Crisper drawer tilted to the right when pulled out
6 of 8 people
found this instruction helpful.
-
William from Heathsville, VA
- Really Easy
- 30 - 60 mins
The repair consisted of lifting up the drawer cover and replacing it. Why the 60 minutes to do that? It took 58 minutes to clean the refrigerator.
Was this helpful?
Thank you for voting!
The refrigerator door was hanging low and not closing properly. Hence the refrigerator was not maintaining the temperature
8 of 14 people
found this instruction helpful.
-
jairaj from North grafton, MA
- Really Easy
- 15 - 30 mins
-
Screw drivers
First removed the three screws at the top that holds the door at the top. Removed the worn out lower door cam after removing one screw. Did the same on the door closing cam (in fact this cam has worn and broken into two pieces). Replaced with the new ones, put the screws back, mounted the door and replaced the three screws on top. The
... Read more
door closed perfectly.
Since this did not help with keeping the refrigerator cold, a day later I had to vacuum the dust off the coils (on the underside of the refrigerator) and thaw the ice from the freezer compartment clearing the ducts to re-initiate the proper flow of air between the two compartments (I learnt on the internet that cold air from the freezer is drawn to maintain the temperature in the refrigerator compartment). The faulty refrigerator door ended up icing our frost free referigerator's freezer compartment and the air ducts in it. Therefore I had to simply turn off the refrigerator for 12 hours, thaw everything and restart! I know nothing about refrigerators. Just did it after visiting your site and a couple of other sites. Saved me about $300!!
Since this did not help with keeping the refrigerator cold, a day later I had to vacuum the dust off the coils (on the underside of the refrigerator) and thaw the ice from the freezer compartment clearing the ducts to re-initiate the proper flow of air between the two compartments (I learnt on the internet that cold air from the freezer is drawn to maintain the temperature in the refrigerator compartment). The faulty refrigerator door ended up icing our frost free referigerator's freezer compartment and the air ducts in it. Therefore I had to simply turn off the refrigerator for 12 hours, thaw everything and restart! I know nothing about refrigerators. Just did it after visiting your site and a couple of other sites. Saved me about $300!!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator had shut down
7 of 11 people
found this instruction helpful.
-
Ronald from Martinsville, IL
- Really Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST
Was this helpful?
Thank you for voting!
The frig/freezer shut off too often and would not stay cold.
7 of 11 people
found this instruction helpful.
-
Ron from Eaton Rapids, MI
- Easy
- Less than 15 mins
-
Nutdriver, Screw drivers
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy f
... Read more
ix.
Read less
Was this helpful?
Thank you for voting!
The Switch Broke...Absolutely Fell Apart.
5 of 5 people
found this instruction helpful.
-
Duncan from Metairie, LA
- Really Easy
- Less than 15 mins
-
Screw drivers
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Was this helpful?
Thank you for voting!
light bulb in water ice freezer door went bad
8 of 14 people
found this instruction helpful.
-
Carl from RIVERSIDE, CA
- Very Difficult
- More than 2 hours
-
Screw drivers
I didn't. Don't know how to get to light bulb to change it for this specific model
Was this helpful?
Thank you for voting!
Unit kept icing up
5 of 5 people
found this instruction helpful.
-
JERRY from TREASURE IS, FL
- A Bit Difficult
- 1- 2 hours
-
Nutdriver, Pliers, Screw drivers
I FOLLOWED A U TUBE VIDEO. IT WAS ALMOST PERFECT FOR MY SIDE BY SIDE REFRIGERATOR.
Other Parts Used:
Was this helpful?
Thank you for voting!
The door light socket was broken and hanging down
6 of 9 people
found this instruction helpful.
-
David from Roanoke, VA
- Really Easy
- Less than 15 mins
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this tim
... Read more
e, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Read less
Was this helpful?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
6 of 9 people
found this instruction helpful.
-
Wayne from Arlington, TX
- A Bit Difficult
- Less than 15 mins
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causin
... Read more
g the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Read less
Was this helpful?
Thank you for voting!
Refrigerator door wouldn't self-close
5 of 6 people
found this instruction helpful.
-
Stephen from Fresno, CA
- Easy
- Less than 15 mins
-
Socket set
Super-easy... First, empty refrigerator door. Then, just remove the bolt that goes through the cover over the top hinge. This exposes three more small bolts. Remove these and the top hinge assembly will lift off. Lift door off. Remove cam from door and lower hinge, slip new cams on, and reassemble. The hardest part was pulling all of the
... Read more
junk stuff out of the refrigerator door. Who know you could accumulate so much salad dressing?
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator door of our double door not closing
5 of 6 people
found this instruction helpful.
-
David from Fort Collins, CO
- Really Easy
- Less than 15 mins
-
Nutdriver, Socket set
Removed the top bracket (3 5/16 size hexhead bolts)
Lifted door free of the bottom cam and hinge socket
(after, of course removing the items from the door shelves!)
removed one bolt holding the lower came to the cabinet.
Pried the cam loose, replaced with new and re-bolted
removed one bolt from cam on door - unabl ... Read more e to remove cam until I removed the guard bracket (two more bolts)
worked the plastic cam from the door by twisting it and pulling the socket from it's hole.
Slipped the new cam into the socket hole, aligned the bolt hole and bolted it tight.
Aligned the top cam to the bottom cam as I replaced the door. Re-attached the top bracket.
All bolts were 5/16
Door now works perfectly again.
Lifted door free of the bottom cam and hinge socket
(after, of course removing the items from the door shelves!)
removed one bolt holding the lower came to the cabinet.
Pried the cam loose, replaced with new and re-bolted
removed one bolt from cam on door - unabl ... Read more e to remove cam until I removed the guard bracket (two more bolts)
worked the plastic cam from the door by twisting it and pulling the socket from it's hole.
Slipped the new cam into the socket hole, aligned the bolt hole and bolted it tight.
Aligned the top cam to the bottom cam as I replaced the door. Re-attached the top bracket.
All bolts were 5/16
Door now works perfectly again.
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!