It was not coming out of defrost cycle
25 of 45 people
found this instruction helpful.
-
Dale from Flemingsburg, KY
- Easy
- 30 - 60 mins
-
Nutdriver, Screw drivers
First I installed a defrost timer, (the old timer had burnt out contacts in it) It seemed to work for a few days, then went back to not comng out of defrost cycle, I then installed a defrost thermostat. It seems to be working better than before. I found out that maybe I wasn't running it cold enough. So I turned it up colder. Now it
... Read more
works ok for 2 - 3 days, then I check the Temp in the freezer and its up to 6o. So I manually reset the timer and it works for 2 - 3 days. Don't know what to do now to fix it.
Read less
Was this helpful?
Thank you for voting!
Refrigerator & Freezer both stopped cooling
16 of 18 people
found this instruction helpful.
-
Clyde from ARAB, AL
- A Bit Difficult
- 15 - 30 mins
-
Nutdriver
Simply move the appliance for access to the back side. Removed the lower metal access panel, locate the compressor ( black round object ) parts are on the left bottom of the compressor. Simply unplug the parts, and replace with new parts.The hard part was, getting my 72 year old body in position to do the job. As far as getting the right
... Read more
part, a young lady in Nova Scoita is the one to ask for help !! Ordered parts one day, and they were in my hands the next morning!!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Refrigerator No Longer Cooling Properly
15 of 15 people
found this instruction helpful.
-
Elizabeth from DELRAY BEACH, FL
- A Bit Difficult
- More than 2 hours
-
Nutdriver, Screw drivers
Approximately:
1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi ... Read more -mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.
This worked! Yahoo.
p.s. I am a 65+ year old mechanically minded woman. :-)
1. Unplugged refrigerator.
2. Emptied Freezer.
3. Removed Ice Maker.
4. Waited a few hours for ice to melt around back panel & nuts.
5. Removed back panel and the cover over fan and fan motor.
6. Waited many more hours for ice to thaw over fins, wiring, etc.
7. Easily replaced the bi ... Read more -mental defrost thermostat.
8. Replaced panel, fan cover, ice maker.
9. Plugged in refrigerator and waited a bit.
This worked! Yahoo.
p.s. I am a 65+ year old mechanically minded woman. :-)
Read less
Was this helpful?
Thank you for voting!
Fridge wont defrost
23 of 41 people
found this instruction helpful.
-
james from Mcdonough, GA
- Very Difficult
- 15 - 30 mins
-
Nutdriver
Freezer freezes and wont defrost. Ice clogs up the coils and the fridge gets hot. Repairman said it was the timer so I replaced that and it didnt fix it. Ordered defrost heater and installed and it is still not fixed. 150$ so far. Should have thrown it away like the repairman suggested.
Was this helpful?
Thank you for voting!
The icemaker in the fridge stopped working
18 of 27 people
found this instruction helpful.
-
Rebecca from Dayton, OH
- Really Easy
- Less than 15 mins
-
Screw drivers
The repair was so simple. I removed the old icemaker in about 3 minutes and unpacked and installed the new one is about 10 minutes. It was literally a matter of removing a few screws! Eady to follow instructions!
Was this helpful?
Thank you for voting!
would not defrost and would not get cold.
13 of 14 people
found this instruction helpful.
-
Jack from Beardstown, IL
- Really Easy
- Less than 15 mins
-
Screw drivers
Had alot of frost build up, coils were frozen solid. Removed the coil cover to defrost.
Ordered the defrost timer on friday, arrived on saturday. only took 15 minutes to install. Working great
Ordered the defrost timer on friday, arrived on saturday. only took 15 minutes to install. Working great
Was this helpful?
Thank you for voting!
light inside fridge was flickering and clicking
20 of 35 people
found this instruction helpful.
-
bill from escondido, CA
- Easy
- 15 - 30 mins
-
Nutdriver
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Was this helpful?
Thank you for voting!
evaporator iced up every 5 days or so
14 of 18 people
found this instruction helpful.
-
nicholas from riverside, CA
- Really Easy
- Less than 15 mins
-
Pliers
Very easy, unscrewed control panel cover (1 screw) which is located under the freezer compartment inside the refrigerator. Took out non working defrost timer installed new one replaced cover, done. Total time: less than 5 minutes.
Was this helpful?
Thank you for voting!
Clicking noise, getting louder. Then stopped cooling
13 of 15 people
found this instruction helpful.
-
James from MEMPHIS, TN
- Really Easy
- 30 - 60 mins
-
Nutdriver
1. Empty your fridge. Lighter is easier to move and this is the hardest step in the fix. 2. Move your fridge so you can get behind it. Unplug the fridge. 3. Use a 1/4in nut driver to remove the screws from the back panel. 4. Remove the back panel. 5. Locate the compressor (big cylinder, usually black) and find the capacitor (PS11757023) a
... Read more
nd start dev (PS11750123) plugged into the side of the compressor. 6. There is a steel spring restraint wire, remove this. 7. Remove the pin connector (plastic w/ wires going to it) by pressing and pulling gently. Remove the old capacitor and start dev. 8. Assemble the new capacitor and start dev to each other. 9. Plug the pin connector into the new replacement components. 10. Align the start dev to the location of the old components. There is a 3 pin outlet that aligns to the 3 plug holes on the start dev. Align the plug then push gently but firmly to seat the components back together. 11. Reinstall the restraint wire. 12. Reinstall the pack panel. 13. Put your refrigerator back in place and load it up! You're all done!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Wrong electrical connector.
13 of 16 people
found this instruction helpful.
-
ROBERT from BUENA PARK, CA
- Very Difficult
- More than 2 hours
I bought a new Whirlpool Refrigerator that didn't have an ice maker.
I wanted to install an ice maker. I searched your web site and found the model ice maker model it said I needed. WPW10715709. This one was a 4 wire 8 terminal. I needed a 4 wire flat connector. WPW10715708. You approved the return. It cost me $50 to return it. I bel ... Read more ieve you should refund me the cost of this postage. Your web site gave me the wrong model number.
Thank you
I wanted to install an ice maker. I searched your web site and found the model ice maker model it said I needed. WPW10715709. This one was a 4 wire 8 terminal. I needed a 4 wire flat connector. WPW10715708. You approved the return. It cost me $50 to return it. I bel ... Read more ieve you should refund me the cost of this postage. Your web site gave me the wrong model number.
Thank you
Read less
Was this helpful?
Thank you for voting!
Scratches in Surface
83 of 227 people
found this instruction helpful.
-
Michelle from Richardson, TX
- Really Easy
- Less than 15 mins
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
Was this helpful?
Thank you for voting!
Refrigerator and freezer was not "working " ,ice machine not working.
11 of 12 people
found this instruction helpful.
-
Guy from MUNSTER, IN
- Easy
- 30 - 60 mins
-
Pliers, Screw drivers, Socket set
Removing the panels inside the freezer section was the most difficult ,because it is narrow,hard to fit your body inside compartment, in order to cut wires and to splice Bi-metal Defrost Thermostat wires (2 ) Watch the videos on the web site so you know where to start. First time I ever "repaired " a large appliance, s
... Read more
aved me over $ 600.00 (that's what the people I bought the Refrigerator from wanted to charge me.) My parts cost 65.00 !!!!! My younger brother turned me onto the web site... , I'll be returning to the site and telling my friends about it. It's a total "rip off" what service organizations charge the general public these days from Car Dealer ships to the stores we purchase our appliances from. !!! Glad I still have my health and faculties to repair the essentials we have around our homes. !!!!
Read less
Other Parts Used:
Was this helpful?
Thank you for voting!
Clicking & popping for about 30 sec. when compressor starts
10 of 10 people
found this instruction helpful.
-
Michael from SCOTTSDALE, AZ
- Really Easy
- 30 - 60 mins
-
Nutdriver, Pliers
As shown on the YouTube link sent with email receipt.
Removed back panel. Removed the clip securing the parts with long nose pliers. Unplugged the old, replugged the new. Replaced the clip to secure.
Unfortunately, the capacitor and relay did not fix the loud clicking issue.
Removed back panel. Removed the clip securing the parts with long nose pliers. Unplugged the old, replugged the new. Replaced the clip to secure.
Unfortunately, the capacitor and relay did not fix the loud clicking issue.
Other Parts Used:
Was this helpful?
Thank you for voting!
installed ice maker
13 of 19 people
found this instruction helpful.
-
Dennis from Spring Valley, MN
- Easy
- 15 - 30 mins
-
Nutdriver, Pliers, Screw drivers, Wrench set
From the time I started to finish I worked 3 hours, this included installing the new ice maker, cutting into the cold water line in the basement and installing a t with a 6inch piece of pipe with a compression valve to connect to the small cooper tube, this is worth your time to do it this way, its a lot better connection than the small p
... Read more
ierce valves that come with the kit, they will leak over time. I installed the filter in the waterline in the basement for easy access
Read less
Was this helpful?
Thank you for voting!
socket melted with bulb in it.
12 of 18 people
found this instruction helpful.
-
martin l. from JACKSONVILLE,, IL
- Really Easy
- Less than 15 mins
plastic warped in ,spaced out and, the socket snapped back in place.
Was this helpful?
Thank you for voting!