3 inches of frost in Fridge, 72 degrees in Fridgerator
6 of 10 people found this instruction helpful.
  • Gerald from Orangeburg, SC
  • Easy
  • 15 - 30 mins
  • Nutdriver, Screw drivers
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Was this helpful?
Thank you for voting!
Refrigerator light would not turn on.
5 of 8 people found this instruction helpful.
  • Suzanne from STERLING HTS, MI
  • Really Easy
  • Less than 15 mins
  • Nutdriver
I first replaced the switch and had no results, I then ordered the Light Socket Kit, and because I had the experience of removing the panel to replace the switch, it took a few minutes to remove the two screws behind the panel, removing the temperature control knobs and then releasing the face plate which is secured by tabs at the bottom. The kit came with extra connectors in case they were needed, but they were not in my case and so I pulled off the wires, pushed the old socket out and the new one in. Attaching the wires to the correct pins, I screwed in the light bulb to be sure that the fix was correct and determining that, I replaced the screws that held the panel in place. Voila, I'm a happy camper who found some outdated jars in the back corners of the newly lighted shelves.
Was this helpful?
Thank you for voting!
Filler tube broken and old tube frozen over
4 of 5 people found this instruction helpful.
  • Alan from Chino, CA
  • Really Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?
Was this helpful?
Thank you for voting!
Broken filler tube at threaded connection
4 of 5 people found this instruction helpful.
  • Matthew from Phoenix, AZ
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Was this helpful?
Thank you for voting!
Installing old ice maker in new freezer
3 of 3 people found this instruction helpful.
  • Harry from Ten Mile, TN
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.
Was this helpful?
Thank you for voting!
lights wouldn't come on/work in refrigerator
4 of 6 people found this instruction helpful.
  • Jane from Albuquerque, NM
  • Easy
  • 15 - 30 mins
  • Pliers, Screw drivers, Socket set
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80.. .would have been at least $100 to have a repair person come to the house!
Was this helpful?
Thank you for voting!
Raplaced switch
5 of 9 people found this instruction helpful.
  • Winston A from Brooklyn, NY
  • Really Easy
  • Less than 15 mins
  • Pliers
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Was this helpful?
Thank you for voting!
Compressor making excessive noise
5 of 9 people found this instruction helpful.
  • chester from Tampa, FL
  • Easy
  • 30 - 60 mins
  • Nutdriver, Socket set
One front roller was flat on one side. Decided to replace all rollers at same time. Placed shims under unit and removed mounting screws for one front and one rear roller. With new rollers in place, I was able to level the refrigerator side to side, but unable to do so, front to back. Left the new front roller in place and reinstalled the old rear roller. Have decided to replace refrigeratorin the near future. This is one of my few repair failures!
Was this helpful?
Thank you for voting!
Ice Build Up On Evap Coil
4 of 6 people found this instruction helpful.
  • bobbie from belleville, IL
  • Very Difficult
  • 1- 2 hours
  • Nutdriver, Pliers
Removing the old heater coil was a bit of a task as you need to take off all the brackets holding the heater coil and then remove the wiring from back of the coil. Installing the new heater coil assembly in the brackets and feeding the wirings back up to the top was a major task. Need to have long arms as the heater is located way back in the freezer compartment. The part was the exact match. The part was delivered in 2 days. Thanks alot. Will use your site again.
Was this helpful?
Thank you for voting!
Freezer Cold With Ice Forming, Fresh Food Warm...Replacing Heater Elements.
3 of 4 people found this instruction helpful.
  • Rick from Livonia, NY
  • A Bit Difficult
  • 1- 2 hours
  • Nutdriver, Pliers, Screw drivers
1. Removed food from freezer and unplug refrigerator or shut circuit breaker. 2. Removed freezer shelves 3. Unscrew all screws on inside back wall and removed back wall plate. Run a fan to defrost the coils. 4. Unscrewed 4 heater bracket nuts on front of cooling coils and removed heater elements. Mine were burnt so I knew I had t he correct part. 5. Removed the heater wires from back panel. 6. Install new heater elements being careful not to leave oils from hands on glass tubes and connected 2 wires from heating elements to rear panel. Reinstall nuts to hold heater brackets. 7. Plug in and run refrigerator for 2 hours with doors closed. Remove upper rear panel on fresh food side then use a flat head screwdriver to turn red timer screw above refrigerator thermostat clockwise slowly until compressor shuts down. 8. Open freezer and waited a few minutes to watch defrost heater coils glow. If they don't glow you might need a new thermostat for the freezer which is located on rear panel or a new timer. 9. Unplug and reinstall rear panel and shelves. Plug in. It will take 24 to 48hrs. For temperatures to level out. Good luck.
Was this helpful?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
3 of 4 people found this instruction helpful.
  • John from Holden, MA
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Was this helpful?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
3 of 4 people found this instruction helpful.
  • David from Hemet, CA
  • Really Easy
  • Less than 15 mins
  • Pliers, Screw drivers
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull t he connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Was this helpful?
Thank you for voting!
changed the light bulb still would not work so I figured it was the switch sure enough.
3 of 4 people found this instruction helpful.
  • anthony from HAVELOCK, NC
  • Really Easy
  • 15 - 30 mins
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
Was this helpful?
Thank you for voting!
the light socket broke apart
4 of 7 people found this instruction helpful.
  • Elyse from Skokie, IL
  • Really Easy
  • 15 - 30 mins
  • Screw drivers
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Was this helpful?
Thank you for voting!
The water fill tube 90 fitting broke
3 of 4 people found this instruction helpful.
  • Scott from Crete, IL
  • Really Easy
  • 15 - 30 mins
  • Pliers, Screw drivers
Removed brokent tube fitting from the compression nut.
Removed two screws holding the fill tube. Removed and replaced the fill tube. Direct replacement, no cutting tube length. Reconnect water line to the new fill tube.......Done.
Was this helpful?