High Limit Kit LA-1053

Official part for Norge, Magic Chef, Maytag, Crosley

Bestseller
Install video
Part Location Diagram of LA-1053 Whirlpool High Limit Kit
See part 12 in the diagram
Replacing your Norge Dryer High Limit Kit
( Grid squares measure 1x1 inch )
Price Match
$44.23
In Stock
Order now and your part arrives by Sep 5
 Fits your ADE2!

About This Part

What it does. Why it matters. Everything you need to know for an easy fix.

High Limit Kit Specifications

The high limit kit comes with three separate thermal fuses for dryers. One electric thermal fuse with a limit of 258, one gas high limit at 240, and one gas and electric high limit thermostat with a limit at 300. The thermal fuse kit shuts off the motor in the dryer when it begins to overheat. If the dryer will not heat, is overheated, shuts off too soon, or takes too long to dry then the thermal fuse might have exploded and need to be replaced. For replacement instructions refer to the diagram by manufacturer. For safety, unplug the dryer before installing the part.
Part #LA-1053
Manufactured by Whirlpool for Norge, Magic Chef, Maytag, Crosley

You May Also Need

Genuine OEM: Original Parts. Lasting Repairs.

Because quality isn't optional.

OEM stands for Original Equipment Manufacturer. This means that the company who made your appliance is also supplying the replacement part.

How Buying OEM Parts Can Save You Time and Money
Features OEM Generic
Genuine brand name
Guaranteed to fit
Superior Quality
Long term value

Part Videos

Watch our pros, then fix it yourself.

Replacing your Norge Dryer High Limit Kit

Replacing your Norge Dryer High Limit Kit

About this fix

Common problems and models this part fixes.

Easy 

30 - 60 mins 

What this part fixes:
  • Won’t Start
  • Too hot
  • Not Heating
  • Will Not Start
Works with the following products:
  • Dryer
Part# LA-1053 replaces these:
AP4242472, 3344, LA-1053, 53-0143, 53-0261, 53-1133, 53-1526, K35-601, LA-1053, LA-1053VP, LA1053

Customer Reviews

Real ratings from other people who bought this part.

Average Rating:

★★★★★
★★★★★
48 Reviews
4.8

Out of 5

  • 5 Stars
    45
  • 4 Stars
    1
  • 3 Stars
    0
  • 2 Stars
    0
  • 1 Star
    2
Sort by:
  • 1
  • 2
  • 3
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
  • 1
  • 2
  • 3

Repair Tips

See how others fixed this model. Time, tools, difficulty, and steps that lead to victory!

Easy 

30 - 60 mins 

Average repair rating from 95 real customers like you

Sort by:
  • 1
  • 2
  • 3
Sorry, we couldn't find any existing installation instruction that matched.
My dryer would not work and the light would not come on.
2 of 2 people found this instruction helpful.
  • Willie from CORDOVA, TN
  • Very Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
I unplugged the dryer from the outlet and opened the top of the dryer with a puddy knife .I marked both wires "T" for the one on top and "B" for the one on the bottom. I removed the screw that holds the bracket in place that the High Limit Kit fuse is attached to and removed both wires with a pair of pliers. I made sure that the new fuse was turned the same way as the old fuse. There is some writing on one side and it should be pointing to the back of the dryer. I put the fuse in the bracket and placed the bracket back in the slotted holder placed the screw back in the bracket holder tighten it up hooked the wires up as labeled and closed the top. I plugged the dryer up opened the door and the light came on. After I turned it on it worked then it tripped the breaker. I reset the breaker turned it on again and it worked I haven't had a problem since. Make sure that you use the fuse with the pink dot on it for a electric dryer.
Was this helpful?
Thank you for voting!
Overheating
2 of 2 people found this instruction helpful.
  • Joseph from TARBORO, NC
  • Really Easy
  • 30 - 60 mins
  • Pliers, Screw drivers
Others have shared as well as I can
Was this helpful?
Thank you for voting!
dryer stopped running, no power
2 of 2 people found this instruction helpful.
  • larry from OLNEY, TX
  • Easy
  • 30 - 60 mins
  • Nutdriver, Pliers
I watched the video tape
Was this helpful?
Thank you for voting!
dryer stopped working--completely dead and would not turn on
2 of 2 people found this instruction helpful.
  • Anthony from Limon, CO
  • Really Easy
  • 15 - 30 mins
  • Nutdriver
I suspected the high limit fuse. I unplugged the machine, lifted the top, found the high-limit fuse (about the size of four dimes glued together) just to the right of the heating coil. I pulled the two wires off and taped them together. Plugged the machine back in and it worked perfectly. I made sure the heating coils started to glow red. When the part arrived, I replaced the old unit with the new, plugged the two wires back on, and I was done. Just for additional information, when I touched the heating coil during the repair, it broke. After 16 years, the heating coils get brittle, so I also replaced the heating coil and it's thermostat just above it (about the size of 6 quarters glued together). I hope this gets me another 16 years.
Was this helpful?
Thank you for voting!
Dryer would not start.
1 person found this instruction helpful.
  • Wilfred from FAYETTEVILLE, GA
  • Really Easy
  • 1- 2 hours
Just as described in the installation video provided by Partselect. I replaced the Thermal Fuse and the High Limit Thermostat. The most time was spent replacing the fuse due to it's location.
Was this helpful?
Thank you for voting!
elec.dryer would not start
2 of 3 people found this instruction helpful.
  • Russell from LEESBURG, FL
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver, Pliers
i followed part select instructions that probable cause was either thermal fuse or high limit thermostat.put ohm meter across both & saw thermal fuse(has pink dot on it) part 53-1182 was open.ordered thermal fuse replacement kit. part#LA-1053. the problem i had was after reaching down the side of heating housing removing the bracket with the thermal fuse,replacing & reconnecting it i had a hard time reinstalling the bracket,very tight space & i don't have very big hands.finally got the fuse in it's hole in the bracket & slid & jammed the bracket into the side of the mounting housing & it stayed secure.dryer started
Was this helpful?
Thank you for voting!
Wouldn't start
1 person found this instruction helpful.
  • John from MURPHY, NC
  • A Bit Difficult
  • 30 - 60 mins
  • Nutdriver
followed video except for the second fuse deeper down it was easier to take a piece of string and loop it around the top of the holder so it would not rotate toward the bottom due to the size of the hole for the fuse. hold string loop until bottom of bracket is in place and press top into place as you remove looped string...
Was this helpful?
Thank you for voting!
Wouldn't start
1 person found this instruction helpful.
  • Christopher from WYLIE, TX
  • Really Easy
  • 30 - 60 mins
  • Screw drivers, Socket set
Followed instructions for testing, starting with door switch, then push to start switch, then thermal fuse. Thermal fuse was bad. Replaced thermal fuse. Back in business.
Was this helpful?
Thank you for voting!
Dryer was overheating
2 of 2 people found this instruction helpful.
  • Jerry R. from FALLS CHURCH, VA
  • Very Easy
  • Less than 15 mins
  • Nutdriver, Pliers, Screw drivers
I first unplugged the dryer. I had to move the dryer forward a little. Then I used a screwdriver to pry up the top of the dryer from the front. I positioned the top all the way back until it rested on the front of the cabinet. Make sure it's far enough back so it doesn't accidentally close on you while you are working on it. I located the high limit thermostat right above the heating coils. I unplugged the two wires going to it. I used a nut driver to remove the screw that was holding it to a bracket. I then I removed the two screws that held it to another bracket. I installed the new thermostat to the bracket and then reinstalled it to the bracket above the coils. I plugged the two wires back in and closed the lid. Make sure the dryer vent is still attached if you had to move it. The dryer works fine now and doesn't overheat.
Was this helpful?
Thank you for voting!
Dryer would not start
0 of 1 people found this instruction helpful.
  • PAUL from HUDSON, NH
  • Easy
  • 15 - 30 mins
  • Nutdriver, Pliers
Used key tip to open dryer lid. Used an ohm meter to check door siwtch and fuses; found thermal limit fuse open. Took photo of wiring for reference. Disconnected heat element and fuses. Removed temp sensor from above element and removed screw retaining heater. Needle nose pliers used to remove clip which retains thermal fuse. Replaced thermal fuse with matching color coded dot (purple) and reinstalled clip. Check the seating of clip and fuse, this is an important safety feature. Put element back in place and checked that retaining screw properly secured clip/fuse. Replaced temp sensor with new unit and reinstalled over heater. Connected wiring and used ohm meter to check for shorts to chasis. Verified all connections secure and no loose wire clips. Closed lid, plugged unit into AC and runs perfect. This is a good time to check all lint traps, housing, and duct work for excess lint. Clogged ducts can cause fire an run unit longer than needed to dry clothes. Partselect.com is by far the best repair parts site.
Was this helpful?
Thank you for voting!
  • 1
  • 2
  • 3

DIY Questions and Expert Answers

22 questions answered by our Repair Experts.

Ask our experts a question about this part and we'll get back to you as soon as possible!

Sort by:
  • 1
  • 2
  • 3
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Gerry - For model number PYE2200AYW
September 1, 2017
I believe the high limit switch has tripped and the dryer will not run.. your switches have two listed. a package of three that will shut off and needs to be replaced and a package of one that will shut down and come back as the dryer cools down. do they work in my dryer and if sow which one should i ger?
Chris Boyle Profile
Hi Gerry, Thank you for your inquiry. The thermostats that are listed under your model number are designed to work with your appliance. There is a high limit kit listed under your model number, part number PS2162282. The high limit kit comes with three separate thermal fuses for dryers. One electric thermal fuse with a limit of 258, one gas high limit at 240, and one gas and electric high limit thermostat with a limit at 300. The thermal fuse kit shuts off the motor in the dryer when it begins to overheat. If the dryer will not heat, is overheated, shuts off too soon, or takes too long to dry then the thermal fuse might have exploded and need to be replaced. For replacement instructions refer to the diagram by manufacturer. For safety, unplug the dryer before installing the part. I hope this helps. Thank you and have a great day!
12 people found this instruction helpful.
Was this helpful?
Thank you for voting!
John - For model number pye2300ayw
May 1, 2019
The high limit kit comes with three separate thermal fuses for dryers. One electric thermal fuse with a limit of 258, one gas high limit at 240, and one gas and electric high limit thermostat with a limit at 300. The two smaller thermal fuses has a marker on them. One with a yellow dot and the other with a pink dot. Which one goes with the larger thermal fuse in my electric dryer.
Chris Boyle Profile
Hello John, Thank you for the question. The one with the Pink Dot is for the electric dryer. Hope this helps!
8 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Gerry - For model number PYE2200AYW
September 1, 2017
Original question:I believe the high limit switch has tripped and the dryer will not run.. your switches have two listed. a package of three that will shut off and needs to be replaced and a package of one that will shut down and come back as the dryer cools down. do they work in my dryer and if sow which one should i get? the response repeated what the item said and did not mention the question of the limit switch for for additional or alternate item pn11742806 that will reset?
Chris Boyle Profile
Hi Gerry, Thank you for getting back to us. Please accept our apologies that your previous question was misunderstood. These parts are listed under your model number and are designed to work with your appliance. To verify which part is causing the issue, you will need to check the continuity of each part with a multimeter. I hope this helps with the repair.
5 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Boyd - For model number PYET344AYW
January 29, 2018
I suspect the thermal switch is bad. When i was looking at it, i noticed i could push in the back side of the switch. Is that normal ?
Chris Boyle Profile
Hi Boyd, Thank you for your question. To verify if the switch is bad, you will need to test it with a multimeter. Disconnect the power source to your dryer before you conduct this or any other test. Either unplug the unit from the wall outlet, remove the appropriate fuse from the fuse box, or flip the appropriate breaker in the circuit breaker panel. Your dryer uses multiple thermostats to regulate its internal temperature. The cycle selected determines which thermostat is used. A cycling thermostat can be found somewhere in the path of air that is leaving the drum. It could be found on the blower wheel housing or inside the venting/exhaust system. Dryer thermostats are usually oval shaped and about an inch and a half in length. Also, there should be two wires leading to each thermostat. Label these wires before you remove them so that you are able to correctly reconnect them later. The wires leading to the thermostat are connected using metal slip on connectors. Remove the wires by pulling on the connectors, and not the wires themselves. It may be a good idea to use a pair of needle nosed pliers to help you. Set your multimeter to the R X 1 setting. Take each of your meter's probes and touch one to each terminal. You are testing for continuity, and you should receive a reading of either zero or infinity. At room temperature, testing the thermostat should produce a reading of zero. But if a thermostat is tested when it is heated to its limit, a reading of infinity should be produced. We strongly recommend that you test your thermostat at room temperature. If the test you conduct with your thermostat does not produce these results, then you should replace the component. I hope this helps. Thank you and have a great day!
4 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Ibarionex - For model number PYG10000AWW
February 4, 2018
The thermal high limit component that is being sold here has two connectors while the original one on my dryer has four. Yet, your site indicates that this is the correct part. Could you clarify.
Chris Boyle Profile
Hello, thank you for your question. Yes, per the manufacturer, this is the correct part for your appliance. The part has been changed from the original and should come with instructions for the install of the new parts. Good luck with your repair!
4 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Amit - For model number PYE2300AYW
February 6, 2018
I have verified the thermal fuse is the issue causing the dryer not to start. Do i need the whole high limit kit, or can i just replace the thermal fuse?
Chris Boyle Profile
Hi Amit, Thank you for your question. You would have to buy the kit to get the fuse as that is the only way the part is sold. I hope that helps. Good luck with your repair.
4 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Michael
November 4, 2017
Dryer will not tumble
Chris Boyle Profile
Hi Michael, Thank you for the question.I suggest checking the drum belt or the pulleys. If you wish to resubmit a new question with the model number of the appliance we will be able to verify the correct belt. Look forward to hearing from you!
3 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Nathan - For model number PYE2300AYW
November 22, 2017
Hi, i have a Maytag dryer model number pye2300ayw. My dryer does nothing when i press the start button. I'm suspecting blown fuse, high limit switch kit, etc, but i after closer inspection i could hear a faint hum when i pressed the button. Does this mean it's got to be something else?
Chris Boyle Profile
Hi Nathan, Thank you for contacting us. There are some parts that you will need to check to see which one is causing the issue. You will need to check the high limit thermostats, the belt, the door catch, the timer resistor assembly, the door switch, the timer assembly and the door switch. I hope this helps. Thank you and have a great day!
3 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Philip - For model number NGD7200TW
October 23, 2017
My Amana dryer initial start will heat then after 5 minutes stop heating. what would be the problem. Thank you.
Chris Boyle Profile
Hi Philip, Thank you for your question. There are a couple of parts that you could check. Your radient flame sensor, your thermistor, thermostats, and your ignitor. You can test all of these parts with a multi meter. Good luck with your repair.
2 people found this instruction helpful.
Was this helpful?
Thank you for voting!
Jaime - For model number TLS752 XX LRR
January 28, 2019
I have a german dryer "asko" and no parts exist for this model. I have talked to the asko parts distributor for north america, no parts. Can i replace the thermostat(125f-31f) and thermal fuse (140f-35f) with american parts. How much can i vary from these temperatures and differentials. As i understand it the thermostat can vary from 125-94, 31 being the differential and the same goes for the fuse. Where can i find them where the specs are shown. Most of the sites on show the thermastat specs but not the fuse. Can anyone help. If you want to reply my email is [email protected] thanks
Chris Boyle Profile
Hello Jaime, Thank you for contacting us. I am sorry however I am not able to find any concrete information to advise whether or not you are able to interchange the parts, as often different countries have different safety standards. I suggest reaching out to a local technician or Asko directly. Good luck with your repair. Have a wonderful day!
2 people found this instruction helpful.
Was this helpful?
Thank you for voting!
  • 1
  • 2
  • 3

This Part Also Fits These Models

Don't see your model? Use our Fit Checker to confirm!

Check Part Fit
Part #LA-1053
Brand
Model Number
Description
Norge
7215A REV E
Dryer - Norge Dryer Model 7215A REV E (7215AREVE) Parts
Norge
7215A REV F
Dryer - Norge Dryer Model 7215A REV F (7215AREVF) Parts
Norge
7215A REV G
Dryer - Norge Dryer Model 7215A REV G (7215AREVG) Parts
Norge
7216A REV E
Dryer - Norge Dryer Model 7216A REV E (7216AREVE) Parts
Norge
7216A REV F
Dryer - Norge Dryer Model 7216A REV F (7216AREVF) Parts
Norge
7375A REV E
Dryer - Norge Dryer Model 7375A REV E (7375AREVE) Parts
Norge
7375A REV F
Dryer - Norge Dryer Model 7375A REV F (7375AREVF) Parts
Norge
7430A REV A
Dryer - Norge Dryer Model 7430A REV A (7430AREVA) Parts
Norge
7430A REV B
Dryer - Norge Dryer Model 7430A REV B (7430AREVB) Parts
Norge
7430A REV C
Dryer - Norge Dryer Model 7430A REV C (7430AREVC) Parts
Norge
7430A REV D
Dryer - Norge Dryer Model 7430A REV D (7430AREVD) Parts
Norge
7433A REV A
Dryer - Norge Dryer Model 7433A REV A (7433AREVA) Parts
Norge
7435A REV A
Dryer - Norge Dryer Model 7435A REV A (7435AREVA) Parts
Norge
7435A REV B
Dryer - Norge Dryer Model 7435A REV B (7435AREVB) Parts
Norge
7435A REV C
Dryer - Norge Dryer Model 7435A REV C (7435AREVC) Parts
Norge
7435A REV D
Dryer - Norge Dryer Model 7435A REV D (7435AREVD) Parts
Norge
7435A REV F
Dryer - Norge Dryer Model 7435A REV F (7435AREVF) Parts
Norge
7435A REV G
Dryer - Norge Dryer Model 7435A REV G (7435AREVG) Parts
Norge
7435A REV H
Dryer - Norge Dryer Model 7435A REV H (7435AREVH) Parts
Norge
7440A REV A
Dryer - Norge Dryer Model 7440A REV A (7440AREVA) Parts
Norge
7440A REV B
Dryer - Norge Dryer Model 7440A REV B (7440AREVB) Parts
Norge
7440A REV C
Dryer - Norge Dryer Model 7440A REV C (7440AREVC) Parts
Norge
7440A REV D
Dryer - Norge Dryer Model 7440A REV D (7440AREVD) Parts
Norge
7539A REV A
Dryer - Norge Dryer Model 7539A REV A (7539AREVA) Parts
Norge
7539A REV B
Dryer - Norge Dryer Model 7539A REV B (7539AREVB) Parts
Norge
7540A REV A
Dryer - Norge Dryer Model 7540A REV A (7540AREVA) Parts
Norge
7540A REV B
Dryer - Norge Dryer Model 7540A REV B (7540AREVB) Parts
Norge
7540A REV C
Dryer - Norge Dryer Model 7540A REV C (7540AREVC) Parts
Norge
7540A REV D
Dryer - Norge Dryer Model 7540A REV D (7540AREVD) Parts
Norge
7543A REV A
Dryer - Norge Dryer Model 7543A REV A (7543AREVA) Parts